Rosario Cobo-Soriano

Rosario Cobo-Soriano

Auto-generated profile, based on publicly available information

Rosario Cobo-Soriano

Head of Ophthalmology Service of Henares University Hospital, Refractive Surgeon at Clínica Baviera Madrid

Research Focus & Metrics

Academic Career Length

27Years (2000-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2006 in Ophthalmology
Verified
Journal Article
Closed access
RCRosario Cobo-Soriano
Rosario Cobo-Soriano
JBJaime Beltrán
Jaime Beltrán
JBJulio Baviera
Julio Baviera

1 July 2005 in Journal of Cataract & Refractive Surgery
Verified
Journal Article
Closed access
RCRosario Cobo-Soriano
Rosario Cobo-Soriano
MCMiguel A. Calvo
Miguel A. Calvo
JBJaime Beltrán
Jaime Beltrán
FLFernando L. Llovet
Fernando L. Llovet
JBJulio Baviera
Julio Baviera
Purpose: To analyze refractive, visual, and contrast sensitivity outcomes of laser in situ keratomileusis (LASIK) performed under thin flaps (less than 100 μm), and compare them with those of conventional thicker flaps. Setting: Clínica Baviera, Instituto Oftalmológico Europeo, Madrid, Spain. Methods: This retrospective study comprised 280 consecutive eyes that had LASIK for myopia using the Moria LSK-One microkeratome and the Technolas 217C excimer laser. Efficacy, predictability, and contrast sensitivity indicators were compared between 3 groups of flap thickness: thin (130 μm, n = 53). Results: Refractive results were excellent and comparable between the 3 groups; however, visual outcomes—measured as efficacy, postoperative evolution of uncorrected visual acuity, and contrast sensitivity—test were significantly better in the thin flap group. Efficacy results were 92.9%, 91.0%, and 81.0% in the thin, medium, and thick flap groups, respectively (P<.05), and the rate of enhancements was 0%, 2.3%, and 5.6%, respectively. With regard to contrast sensitivity, changes between preoperative and postoperative values at month 3 of follow-up, the thin flap group achieved the preoperative levels at 3 spatial frequencies (3, 6, and 18 cycles per degree), while the thicker flap groups maintained lower than preoperative levels at more than 2 spatial frequencies. When comparing contrast sensitivity values between the 3 groups, the thin flap group also obtained the best results at lower spatial frequencies. Conclusions: Thin flap LASIK is a safe technique to correct myopic defects since it blends the advantages of surface and lamellar procedures (minimal debilitation of corneal biomechanical architecture with the rapid and comfortable visual recovery of lamellar approaches). Moreover, it achieves excellent refractive outcomes, a lower rate of enhancements, and a good visual performance with better contrast sensitivity test results.

5 March 2021 in Journal of Cataract & Refractive Surgery
Verified
Journal Article
Closed access
RCRosario Cobo-Soriano
Rosario Cobo-Soriano
Julio Ortega-UsobiagaJulio Ortega-Usobiaga
Julio Ortega-Usobiaga
BRBeatriz Doo Rodríguez-Gutiérrez
Beatriz Doo Rodríguez-Gutiérrez
VTVíctor Doo Tejerina
Víctor Doo Tejerina
FLFernando Llovet
Fernando Llovet
JBJulio Baviera
Julio Baviera
Purpose: To evaluate the visual and refractive outcomes of trifocal intraocular lens (IOL) implantation in eyes previously treated with myopic and hyperopic corneal refractive laser surgery. Setting: Clinica Baviera-AIER-Eye group, Spain. Design: Retrospective comparative case series. Methods: The series was divided into 2 groups according to the type of corneal laser refraction (myopic and hyperopic). The main visual and refractive outcome measures included corrected distance visual acuity (CDVA) and uncorrected distance and near visual acuity, safety, efficacy, and predictability. The secondary outcome measures were percentage of enhancement and Nd:YAG capsulotomy and influence of prelaser magnitude of myopia and hyperopia on the outcome of trifocal IOL implantation. Results: The sample comprised 868 eyes (543 patients): myopic, n = 319 eyes (36.7%); and hyperopic, n = 549 eyes (63.2%). Three months postoperatively, visual outcomes were poorer in the hyperopic group than those in the myopic group for mean CDVA (0.06 ± 0.05 vs 0.04 ± 0.04, P < .01) and safety (21% vs 12% of CDVA line loss, P < .05) outcomes. However, precision outcomes were worse in the myopic group than those in the hyperopic group, with a mean spherical equivalent of −0.38 ± 0.3 vs −0.17 ± 0.3 (P < .01). Stratification by magnitude of primary laser treatment revealed poorer visual and safety results in the high hyperopia subgroup (>+3.0 diopters [D]) and poorer precision in the high myopia subgroup (<−5.0 D). Conclusions: Trifocal IOL implantation after photorefractive surgery in eyes previously treated with myopic ablation achieved good visual outcomes but less predictability in the high myopia subgroup. However, eyes with a previous hyperopic corneal ablation achieved excellent precision but worse visual and safety outcomes in the high hyperopia subgroup.

7 December 2023 in Eye and Vision
Verified
Journal Article
Open access
PDF file
FMFernando Mayordomo-Cerdá
Fernando Mayordomo-Cerdá
Julio Ortega-UsobiagaJulio Ortega-Usobiaga
Julio Ortega-Usobiaga
JBJulio Baviera-Sabater
Julio Baviera-Sabater
RBRafael Bilbao-Calabuig
Rafael Bilbao-Calabuig
FLFernando Llovet-Osuna
Fernando Llovet-Osuna
RCRosario Cobo-Soriano
Rosario Cobo-Soriano
Background: To assess whether a trifocal intraocular lens (IOL) with neutral spherical aberration (SA) provides better visual and refractive outcomes than a trifocal IOL with negative SA after hyperopic corneal laser ablation. Methods: This is a retrospective comparative study. Patients were classified according to the IOL implanted after cataract or clear lens phacoemulsification [group 1, PhysIOL FineVision Pod-F (negative SA); group 2, Rayner RayOne Trifocal (neutral SA)]. We evaluated uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), uncorrected intermediate visual acuity (UIVA), uncorrected near visual acuity (UNVA), predictability, safety, efficacy, and satisfaction. Results: 198 eyes of 119 patients met the inclusion criteria. Group 1 comprised 120 eyes and group 2 comprised 78 eyes. At completion, the refractive and predictability results were significantly better in group 1 than in group 2 for manifest refraction spherical equivalent (MRSE) (P < 0.001). Differences were not significant for UDVA (P = 0.647), CDVA (P = 0.343), UIVA (P = 0.059), UNVA (P = 0.382), binocular UIVA (P = 0.157), or binocular UNVA (P = 0.527). Safety and efficacy indices in refractive lens exchange (RLE) eyes were 0.96 and 0.91, and 0.89 and 0.93 in groups 1 and 2, respectively (P = 0.254 and 0.168). Patient satisfaction was similar in both groups (P > 0.05, all items). Conclusion: In eyes previously treated with hyperopic corneal ablation, implantation of a trifocal IOL with neutral SA provided better efficacy and safety outcomes but worse predictability outcomes than those obtained with a trifocal model with negative SA.

1 October 2019 in Saudi Journal of Ophthalmology
Verified
Journal Article
Open access
JMJulio González Martín-Moro
Julio González Martín-Moro
LILourdes Iglesias-Ussel
Lourdes Iglesias-Ussel
RCRosario Cobo-Soriano
Rosario Cobo-Soriano
YFYolanda Fernández-Miguel
Yolanda Fernández-Miguel
ICInés Contreras
Inés Contreras
Malignant glaucoma usually occurs after anterior segment surgery (typically after glaucoma surgery). The aim of this article is to report a case of spontaneous malignant glaucoma (SpMG), which required phacovitrectomy for resolution and to review the cases of SpMG reported in modern literature. Only nine cases were identified. SpMG has no gender predilection and age at onset seems to be lower (mean age 47 years) than in secondary malignant glaucoma (SeMG). Nearly in half of the reported patients (4 out of 9) the condition had a bilateral presentation. The risk factors that have been identified for SeMG (nanophthalmos, shallow anterior chamber, iris plateau, zonular laxity) are underrepresented in SpMG.

25 October 2013 in International Ophthalmology
Verified
Journal Article
Closed access
PDF file
JMJulio González Martín-Moro
Julio González Martín-Moro
JGJulio José González-López
Julio José González-López
FGFernando Gómez-Sanz
Fernando Gómez-Sanz
JZJesús Zarallo-Gallardo
Jesús Zarallo-Gallardo
RCRosario Cobo-Soriano
Rosario Cobo-Soriano