Sunirmit Verma

Sunirmit Verma

Auto-generated profile, based on publicly available information

Sunirmit Verma

Chandigarh University

Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2026
Verified
Conference Paper
Closed access
SVSunirmit Verma
Sunirmit Verma
MSMukhtiar Singh
Mukhtiar Singh
ASAdityabir Singh
Adityabir Singh
MSMayukh Sarkar
Mayukh Sarkar
ISInderjit Singh
Inderjit Singh
PSParminder Singh
Parminder Singh


22 June 2026 in Engineering Research Express
Verified
Journal Article
Closed access
SVSunirmit Verma
Sunirmit Verma
ASAdityabir Singh
Adityabir Singh
BKBasanth Kumar Kodli
Basanth Kumar Kodli
BMBhargav Majmundar
Bhargav Majmundar
KSKiran K S
Kiran K S
AKAshok Kumar
Ashok Kumar
Solar ponds are a type of solar thermal energy storage devices which comprise three distinct zones: the top zone, the gradient zone, and the storage zone. Among these zones, heat for industrial applications is primarily extracted from the gradient and storage zones. The base layer insulation plays a very important role, as it governs the heat loss from the base of the pond. However, in the literature, the optimum base insulation thickness for salt gradient ponds was evaluated under energy extraction from the storage zone alone. This work is an attempt to carry the same investigation by including gradient zone energy extraction as well, and to quantify how much error this additional heat extraction introduces into the calculation. A transient heat transfer model is used to calculate year-round extraction temperatures based on the zone thicknesses, the pond cross-sectional area, and the mass flow rate of water in the gradient/storage heat exchanger. While calculating the best base thermal insulation thickness, the selected criterion is the insulation thickness at which the increase in maximum extraction temperature is less than 0.01 oC. The study is extended for four different mass flow rates of working fluid in the gradient zone heat exchanger: 0.00, 0.02, 0.04,0.06 kg.s-1, and the storage zone heat exchanger: 0.00, 0.02, 0.04,0.06 kg.s-1. It is seen that the operation of the gradient zone exchanger drastically reduces the required amount of base insulation thickness. The reduction in optimal base insulation thickness at gradient zone exchanger mass flow rates of 0.02 kg.s-1, 0.04 kg.s-1and 0.06 kg.s-1 is 18.46%, 38.46%, and 56.92% respectively, compared to the no gradient zone heat extraction case. It is also observed that the optimum base insulation thickness increases with an increase in pond area and decreases with an increase in all other parameters mentioned in the study.