5 February 2025 in Nature
7 July 2021 in Science Translational Medicine
Combined induced pluripotent stem cells and airway-on-a-chip establish the global axis of planar cell polarity in patient-derived airway cell sheet.
26 November 2009 in American Journal of Neuroradiology
BACKGROUND AND PURPOSE: Optimal tube voltage and tube current settings are not well established. The purpose of our study was to investigate the image quality on 3D CT angiograms of the brain at various kilovoltage settings by evaluating the depiction of simulated intracranial lesions by using a vascular phantom. MATERIALS AND METHODS: An anthropomorphic vascular phantom with superimposed bone skull structures was designed to simulate various intracranial aneurysms with aneurysmal blebs. We performed CT angiography by using a 64-detector row CT scanner for various effective tube currents with 4 tube voltages of 80, 100, 120, and 135 kV(p). Simulated aneurysm enhancement and image noise were quantified; SNR and CNR were calculated. The depiction of the simulated aneurysms and blebs on 3D CT angiograms obtained with the volume-rendering technique was subjectively assessed. The effective dose was calculated on the basis of a CTDIw. The results of several protocols were compared by using the Student t test. RESULTS: At identical doses levels (CTDIw), the mean SNR and CNR at 100 kV(p) were significantly higher than those at 80, 120, and 135 kV(p); and the mean qualitative image score at 100 kV(p) was significantly superior to those at 80 and 135 kV(p). CONCLUSIONS: Our phantom study suggests that the tube voltage of 100 kV(p) is desirable for cerebral 3D CT angiograms, and the higher or lower kilovoltage settings may result in the degradation in diagnostic image quality.
1 September 2021 in Biomaterials
Lung transplantation is the only treatment available for end-stage lung diseases; however, donor shortage is a global issue. The use of human pluripotent stem cells (hPSCs) for organ regeneration is a promising approach. Nevertheless, methods for the expansion of isolated hPSC-derived lung progenitors (hLPs) for transplantation purposes have not yet been reported. Herein, we established an expansion system of hLPs based on their three-dimensional culture in core-shell hydrogel microfibers, that ensures the maintenance of their bipotency for differentiation into alveolar and airway epithelial cells including alveolar type II (AT2) cells. Further, we developed an efficient in vivo transplantation method using an endoscope-assisted transtracheal administration system; the successful engraftment and in vivo differentiation of hLPs into alveolar epithelial cells (incorporated into the alveoli) was observed. Importantly, expanded hLPs in the context of microfibers were successfully transplanted into the murine lungs, opening avenues for cell-based therapies of lung diseases. Therefore, our novel method has potential regenerative medicine applications; additionally, the high-quality hLPs and AT2 cells generated via the microfiber-based technology are valuable for drug discovery purposes.
1 January 1996 in Acta Radiologica
Purpose: This experimental study was designed to investigate the effect of irradiation in prevention of intimal hyperplasia. Material and Methods: Twenty rabbits were divided into 4 groups, which were irradiated with 2, 5, 10, and 20 Gy, respectively. The intima of both femoral arteries was injured by air-drying, and irradiation was performed on the unilateral side. The contralateral femoral artery served as a control. Angiograms as well as histologic specimens were obtained 1 month later. Results: Marked intimal hyperplasia was observed in all control sites. There were no significant differences in thickness of intimal hyperplasia between irradiated and control sites in groups irradiated with 2 and 5 Gy. However, in the 10-Gy- and 20-Gy-irradiated groups, intimal hyperplasia of the irradiated site was significantly suppressed. Medial thinning and dilation of the lumen were observed in the 20-Gy-irradiated group. Conclusion: Radiation may prevent intimal hyperplasia. Further investigation of the optimal dose, timing of irradiation, and long-term patency of irradiated vessels may be needed.