Objectives: Characterize the safety and effectiveness of the Amplatzer Piccolo Occluder for patent ductus arteriosus (PDA) closure.Background: The presence of a hemodynamically significant PDA has been associated with an increased risk of morbidity and mortality in children born premature.Methods: This was a single arm, prospective, multicenter, non‐randomized study to evaluate the Amplatzer Piccolo Occluder to treat PDA in patients ≥700 g. From June 2017 to February 2019, 200 patients were enrolled at nine centers, with 100 patients weighing ≤2 kg. Primary effectiveness endpoint was the rate of PDA closure at 6‐month follow‐up. Primary safety endpoint was the rate of major complications through 6 months. Secondary endpoint was rate of significant pulmonary or aortic obstruction through 6 months' follow‐up.Results: The implant success rate was 95.5% (191/200) overall and 99% in patients ≤2 kg (99/100). The primary effectiveness endpoint was achieved in 99.4% of implanted patients. Four patients experienced a primary safety endpoint event (2 transfusions, 1 hemolysis, and 1 aortic obstruction). There were no branch pulmonary artery obstructions. Five patients, all ≤2 kg, were noted to have worsening of tricuspid regurgitation (TR) after the procedure. None of the TR incidences manifested clinically. The Amplatzer Piccolo Occluder received FDA approval in January 2019 and became the first device approved for PDA closure in patients ≥700 g.Conclusions: This study supports the safety and effectiveness of the Amplatzer Piccolo Occluder, particularly in patients between 700 g and 2 kg where there is currently a significant unmet need in the United States. ClinicalTrials.gov identifier: NCT03055858.
Background: Tissue-engineered vascular grafts (TEVGs) have the potential to advance the surgical management of infants and children requiring congenital heart surgery by creating functional vascular conduits with growth capacity. Methods: Herein, we used an integrative computational-experimental approach to elucidate the natural history of neovessel formation in a large animal preclinical model; combining an in vitro accelerated degradation study with mechanical testing, large animal implantation studies with in vivo imaging and histology, and data-informed computational growth and remodeling models. Results: Our findings demonstrate that the structural integrity of the polymeric scaffold is lost over the first 26 weeks in vivo, while polymeric fragments persist for up to 52 weeks. Our models predict that early neotissue accumulation is driven primarily by inflammatory processes in response to the implanted polymeric scaffold, but that turnover becomes progressively mechano-mediated as the scaffold degrades. Using a lamb model, we confirm that early neotissue formation results primarily from the foreign body reaction induced by the scaffold, resulting in an early period of dynamic remodeling characterized by transient TEVG narrowing. As the scaffold degrades, mechano-mediated neotissue remodeling becomes dominant around 26 weeks. After the scaffold degrades completely, the resulting neovessel undergoes growth and remodeling that mimicks native vessel behavior, including biological growth capacity, further supported by fluid–structure interaction simulations providing detailed hemodynamic and wall stress information. Conclusions: These findings provide insights into TEVG remodeling, and have important implications for clinical use and future development of TEVGs for children with congenital heart disease.
Objective: This study describes 3-year follow-up of 200 infants weighing ≥ 700 grams who underwent transcatheter patent ductus arteriosus (PDA) closure with the Amplatzer Piccolo™ Occluder. Study Design: Between June 2017 and February 2019, 200 children were enrolled in this U.S. study (NCT03055858). PDA closure, survival, and device- or procedure-related events were evaluated. A total of 156 of the available 182 patients (86%) completed the study. Results: The implant success rate was 95.5% (191/200). At 3 years, PDA closure was observed in 100% (33/33) of patients. Survival was >95% with 9 reported deaths. No deaths were adjudicated as device- or procedure-related. Notable events included aortic obstruction (2) requiring stent placement and tricuspid regurgitation (5), for which no interventions were required. Conclusions: This follow-up study demonstrates high rates of PDA closure, low serious complication rates, and survival > 95% at 3 years. The Amplatzer Piccolo™ Occluder is a safe and effective therapy for PDA treatment in premature infants. ClinicalTrials.gov identifier: NCT0305585.
16 August 2019 in Catheterization and Cardiovascular Interventions
Background: Stent implantation (SI) is more effective than balloon angioplasty for the treatment of coarctation of the aorta (CoA). Due to technical factors, balloon angioplasty is more commonly performed in small patients. We sought to evaluate outcomes of percutaneous adult sized SI for the treatment of CoA in small patients. Methods: A single-center retrospective review of all patients ≤20 kg who underwent percutaneous adult sized SI for native or recurrent CoA from 2004 to 2015 was performed. Results: Thirty-nine patients (20 patients ≤10 kg) were identified, with 28 (71.8%) having recurrent CoA and 22 (56.4%) previously failed balloon angioplasty. At the time of SI, the median (range) patient age and weight were 1.1 (0.3–7.9) years and 10 (5.5–20.4) kg, respectively. SI resulted in significant improvements in the median gradient (26 mm Hg [interquartile range (IQR), 18–42] to 0 mm Hg [IQR, 0–2]; P < 0.05) and median minimum diameter (3.6 mm [IQR, 2.4–4.8] to 7.7 mm [IQR, 6.5–9.4]; P <0.05). Seven patients (18%) had procedural adverse events. Twenty-seven (69%) patients underwent elective reintervention at a median time of 49.3 (IQR, 26.5–63.2) months from SI, with 8 (21%) stents requiring repeat SI for stent fracture. Over a median follow-up of 67.2 (IQR, 33.8–116.1) months, 25 patients (69%) were without hypertension or blood pressure gradient. Three (11%) patients developed femoral arterial occlusion. Conclusions: Adult sized SI is an alternative to surgical intervention for small patients with CoA. SI carries a risk of access-related complications, which may improve with the development of lower profile stents with adult sized maximum diameters.
26 March 2020 in Catheterization and Cardiovascular Interventions