16 December 2014 in Radiation Oncology
The accuracy of dose calculation is crucial to the quality of treatment planning and, consequently, to the dose delivered to patients undergoing radiation therapy. Current general calculation algorithms such as Pencil Beam Convolution (PBC) and Collapsed Cone Convolution (CCC) have shortcomings in regard to severe inhomogeneities, particularly in those regions where charged particle equilibrium does not hold. The aim of this study was to evaluate the accuracy of the PBC and CCC algorithms in lung cancer radiotherapy using Monte Carlo (MC) technology. Four treatment plans were designed using Oncentra Masterplan TPS for each patient. Two intensity-modulated radiation therapy (IMRT) plans were developed using the PBC and CCC algorithms, and two three-dimensional conformal therapy (3DCRT) plans were developed using the PBC and CCC algorithms. The DICOM-RT files of the treatment plans were exported to the Monte Carlo system to recalculate. The dose distributions of GTV, PTV and ipsilateral lung calculated by the TPS and MC were compared. For 3DCRT and IMRT plans, the mean dose differences for GTV between the CCC and MC increased with decreasing of the GTV volume. For IMRT, the mean dose differences were found to be higher than that of 3DCRT. The CCC algorithm overestimated the GTV mean dose by approximately 3% for IMRT. For 3DCRT plans, when the volume of the GTV was greater than 100 cm3, the mean doses calculated by CCC and MC almost have no difference. PBC shows large deviations from the MC algorithm. For the dose to the ipsilateral lung, the CCC algorithm overestimated the dose to the entire lung, and the PBC algorithm overestimated V20 but underestimated V5; the difference in V10 was not statistically significant. PBC substantially overestimates the dose to the tumour, but the CCC is similar to the MC simulation. It is recommended that the treatment plans for lung cancer be developed using an advanced dose calculation algorithm other than PBC. MC can accurately calculate the dose distribution in lung cancer and can provide a notably effective tool for benchmarking the performance of other dose calculation algorithms within patients.
1 January 2021 in Technology in Cancer Research & Treatment
Objectives: In breast radiotherapy, the proximity of the target to sensitive structures together with the uncertainty introduced by respiratory movement, make this treatment one of the most studied to increase its effectiveness. Dosimetric and physical variables play an important role and the study of their correlation and impact on treatment is fundamental. This retrospective study aims to highlight the dosimetric differences of 2 different clinical data sets of patients receiving left-sided breast irradiation in free breathing (FB) or breath hold (BH). Methods: A total of 155 left breast carcinoma patients receiving whole-breast irradiation in FB (73 patients) and BH (82 patients) were enrolled in this study. The dosimetric parameters of the target, heart, left and right lung and right breast were evaluated and compared, and possible correlations were studied in both groups. Results: No significant difference (P > .05) was found in the target dosimetry; a clear advantage in BH for both high and low doses received by the heart, with reductions of the dosimetric parameters between 27.1% and 100% (P < .003); for the left lung reductions decreased with increasing dose (−22.4% and −13.4% for doses of 5 and 20 Gy, respectively, P < .003). Conclusion: Significant correlations for BH treatments were registered between the volumes of the target and left lung, and the dosimetric parameters of the heart and left lung. BH treatment brings significant dosimetric advantages to organs at risk for a wide range of patients with different anatomy, target volumes and lung capacity, with additional benefits for small-sized breasts and important lung capacity.