Octavia Bane

Octavia Bane

Auto-generated profile, based on publicly available information

Octavia Bane

Department of Diagnostic, Molecular and Interventional Radiology, Icahn School of Medicine at Mount Sinai, New York, USA

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 November 2019 in Magnetic Resonance Materials in Physics, Biology and Medicine
Verified
Journal Article
Open access
PDF file
OBOctavia Bane
Octavia Bane
IMIosif A. Mendichovszky
Iosif A. Mendichovszky
BMBastien Milani
Bastien Milani
IDIlona A. Dekkers
Ilona A. Dekkers
JDJean-Francois Deux
Jean-Francois Deux
PPPottumarthi V Prasad
Pottumarthi V Prasad
Harmonization of acquisition and analysis protocols is an important step in the validation of BOLD MRI as a renal biomarker. This harmonization initiative provides technical recommendations based on a consensus report with the aim to move towards standardized protocols that facilitate clinical translation and comparison of data across sites. We used a recently published systematic review paper, which included a detailed summary of renal BOLD MRI technical parameters and areas of investigation in its supplementary material, as the starting point in developing the survey questionnaires for seeking consensus. Survey data were collected via the Delphi consensus process from 24 researchers on renal BOLD MRI exam preparation, data acquisition, data analysis, and interpretation. Consensus was defined as ≥ 75% unanimity in response. Among 31 survey questions, 14 achieved consensus resolution, 12 showed clear respondent preference (65–74% agreement), and 5 showed equal (50/50%) split in opinion among respondents. Recommendations for subject preparation, data acquisition, processing and reporting are given based on the survey results and review of the literature. These technical recommendations are aimed towards increased inter-site harmonization, a first step towards standardization of renal BOLD MRI protocols across sites. We expect this to be an iterative process updated dynamically based on progress in the field.

2 November 2020 in Journal of Magnetic Resonance Imaging
Verified
Journal Article
Open access
PDF file
ABAnneloes de Boer
Anneloes de Boer
GVGiulia Villa
Giulia Villa
OBOctavia Bane
Octavia Bane
MBMichael Bock
Michael Bock
ECEleanor F. Cox
Eleanor F. Cox
ACAnna Caroli
Anna Caroli
Background: Phase‐contrast (PC) MRI is a feasible and valid noninvasive technique to measure renal artery blood flow, showing potential to support diagnosis and monitoring of renal diseases. However, the variability in measured renal blood flow values across studies is large, most likely due to differences in PC‐MRI acquisition and processing. Standardized acquisition and processing protocols are therefore needed to minimize this variability and maximize the potential of renal PC‐MRI as a clinically useful tool.Purpose: To build technical recommendations for the acquisition, processing, and analysis of renal 2D PC‐MRI data in human subjects to promote standardization of renal blood flow measurements and facilitate the comparability of results across scanners and in multicenter clinical studies.Study Type: Systematic consensus process using a modified Delphi method.Population: Not applicable.Sequence Field/Strength: Renal fast gradient echo‐based 2D PC‐MRI.Assessment: An international panel of 27 experts from Europe, the USA, Australia, and Japan with 6 (interquartile range 4–10) years of experience in 2D PC‐MRI formulated consensus statements on renal 2D PC‐MRI in two rounds of surveys. Starting from a recently published systematic review article, literature‐based and data‐driven statements regarding patient preparation, hardware, acquisition protocol, analysis steps, and data reporting were formulated.Statistical Tests: Consensus was defined as ≥75% unanimity in response, and a clear preference was defined as 60–74% agreement among the experts.Results: Among 60 statements, 57 (95%) achieved consensus after the second‐round survey, while the remaining three showed a clear preference. Consensus statements resulted in specific recommendations for subject preparation, 2D renal PC‐MRI data acquisition, processing, and reporting.Data Conclusion: These recommendations might promote a widespread adoption of renal PC‐MRI, and may help foster the set‐up of multicenter studies aimed at defining reference values and building larger and more definitive evidence, and will facilitate clinical translation of PC‐MRI.Level of Evidence: 1Technical Efficacy Stage: 1

13 April 2023 in Journal of Magnetic Resonance Imaging
Verified
Journal Article
Closed access
ILIndira Laothamatas
Indira Laothamatas
HMHaitham Al Mubarak
Haitham Al Mubarak
ARArthi Reddy
Arthi Reddy
RWRebecca Wax
Rebecca Wax
KBKetan Badani
Ketan Badani
SLSara Lewis
Sara Lewis

14 October 2018 in Journal of Magnetic Resonance Imaging
Verified
Journal Article
Closed access
PDF file
OBOctavia Bane
Octavia Bane
SPSteven Peti
Steven Peti
MWMathilde Wagner
Mathilde Wagner
SHStefanie Hectors
Stefanie Hectors
HDHadrien Dyvorne
Hadrien Dyvorne
BTBachir Taouli
Bachir Taouli

26 May 2023 in Journal of Magnetic Resonance Imaging
Verified
Journal Article
Closed access
OBOctavia Bane
Octavia Bane
ESErdmann Seeliger
Erdmann Seeliger
ECEleanor Cox
Eleanor Cox
JSJulia Stabinska
Julia Stabinska
EBEric Bechler
Eric Bechler
TNThoralf Niendorf
Thoralf Niendorf

21 January 2019 in Journal of Magnetic Resonance Imaging
Verified
Journal Article
Closed access
PDF file
SHStefanie J. Hectors
Stefanie J. Hectors
OBOctavia Bane
Octavia Bane
PKPaul Kennedy
Paul Kennedy
FSFadi El Salem
Fadi El Salem
MMMadhav Menon
Madhav Menon
BTBachir Taouli
Bachir Taouli