Marius Langwasser

Marius Langwasser

Auto-generated profile, based on publicly available information

Marius Langwasser

Chair of Power Electronics, Kiel University, Kiel, Germany

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 December 2018 in IEEE Transactions on Power Systems
Verified
Journal Article
Closed access
MLMarius Langwasser
Marius Langwasser
GCGiovanni De Carne
Giovanni De Carne
Marco LiserreMarco Liserre
Marco Liserre
MBMatthias Biskoping
Matthias Biskoping
DC faults are critical events for the multi-terminal HVdc protection systems, where knowing the critical fault time is fundamental in the protections design. Existing literature analyzes the critical fault time with simulations or with complex analysis, requiring large computational effort and they are not robust to parameters variations. Furthermore, standard approaches rely on simplified modular multilevel converter (MMC) models neglecting the influence of converter control loops dynamic. As result, the prediction of the node voltages and especially the dc currents become increasingly inaccurate as bigger is the distance from the fault. This paper introduces a fault current estimation method in MMC-based multi-terminal dc (MTdc) grids, which improves the current differential equation based methodologies including the dynamics of power and dc voltage controllers. The proposed method gives the possibility of analyzing the fault current under different grid conditions (e.g., fault resistance and limiting inductor value). Furthermore, this method is extended to bipolar MTdc systems in case of pole-to-pole and pole-to-ground faults, and it is validated by means of simulations in PSCAD environment and standard CIGRE MTdc grid.

21 March 2022 in Proceedings of the IEEE
Verified
Journal Article
Closed access
Marco LiserreMarco Liserre
Marco Liserre
MPMarcelo A. Perez
Marcelo A. Perez
MLMarius Langwasser
Marius Langwasser
Christian A. RojasChristian A. Rojas
Christian A. Rojas
ZZZiqi Zhou
Ziqi Zhou
Power systems are experiencing a rapid and dramatic transformation driven by the massive integration of nondispatchable renewable energy sources, such as wind and solar, and highly variable loads, such as electric vehicles and air conditioning. This challenges existing grid assets, eventually leading to updating them, which, in turn, increases significantly the costs of sustainable technologies. Power electronics is a pivotal technology for electrical power processing for renewable energies and sustainable transportation. By means of ``smart'' functionalities, power electronics converters already embedded in such applications can also contribute to guaranteeing the overall system's stable operation. Anyway, this cooperative contribution from distributed devices may be not enough leading to the need for the voltage transformation and power transmission of ``system-level'' power electronics solutions. In the case of large charging stations, a smart transformer (ST), while, in the case of large solar and wind parks, integration medium- or high-voltage direct current (HVdc) transmissions are system-level solutions. This article wants to review the potential of using such infrastructures to increase the capacity of existing grid assets, avoiding or deferring their upgrade and, hence, reducing the overall costs of renewables integration and the electrification of the transport sector. In fact, the power converters embedded in ST and HVdc can provide fast frequency and voltage response, and precise control of power flow acting at the system level much more effectively and feasibly for system operators as the distributed power converters embedded in several small sources and users. This article reviews, for the first time, these two key power electronics ``system-level'' solutions together--ST and HVdc--starting from their basic functionalities and showings how they can go beyond them, showing how, with grid-forming functionalities, they can offer new ``smart grid'' tools to enhance the capability of the existing electric grid infrastructures.

16 January 2024 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
ZZZiqi Zhou
Ziqi Zhou
SPSante Pugliese
Sante Pugliese
MLMarius Langwasser
Marius Langwasser
Marco LiserreMarco Liserre
Marco Liserre
Wind farms are susceptible to sub-synchronous oscillation (SSO) issues due to the interaction between the grid-side converter (GSC) and the weak-grid impedance. Integration of battery energy storage system (BESS) to damp SSO became popular due to its ability to also provide various grid services. Generally, BESS can be externally integrated at the PCC or internally integrated at the dc-link of the wind turbine (WT). In case of external BESS integration, grid-forming (GFM) control is usually applied to the BESS GSC. Proper increase of the GFM damping coefficient contributes to a better SSO damping, at the cost of a higher BESS power rating due to its droop meaning. Reconfiguring power loop of GFM to decouple the damping and the droop coefficient enables GSC to realize similar SSO damping performance while reducing the BESS power rating. In case of internal BESS integration, a virtual grid-forming control is proposed as an ancillary control of the WT GSC. This enables GSC to emulate the output behavior of two parallel converters, operated in grid-following and GFM mode respectively. Consequently, similar SSO damping performance can be realized without an external GFM converter. Simulation and experimental results are provided to verify the effectiveness of the proposed method.

24 June 2019 in IEEE Industrial Electronics Magazine
Verified
Journal Article
Closed access
GCGiovanni De Carne
Giovanni De Carne
Marco LiserreMarco Liserre
Marco Liserre
MLMarius Langwasser
Marius Langwasser
MNMario Ndreko
Mario Ndreko
RBRalf Bachmann
Ralf Bachmann
FRFreiber Rojas
Freiber Rojas
The high implementation of renewable energy systems (RESs) and the need to increase transmission capacity across Europe (e.g., north-south Germany) have resulted in integrated power electronics (PE)-based solutions in electrical grids. PE allows more flexibility and control over power grids. Solutions such as high-voltage (HV) dc systems and flexible alternating current transmission systems (FACTS) increase energy transfer capabilities while preserving the system's safety (e.g., providing reactive power). Additionally, PE-based solutions, which are characterized by fast dynamic control actions, can support the grid during disturbances [e.g., a low-voltage ridethrough (LVRT) during faults]. These solutions are widely integrated into RES applications, where they enable maximized energy extraction from natural resources (e.g., the maximum power point tracker).

27 October 2023 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Verified
Journal Article
Closed access
JKJohannes Kuprat
Johannes Kuprat
KDKarthik Debbadi
Karthik Debbadi
JSJoscha Schaumburg
Joscha Schaumburg
Marco LiserreMarco Liserre
Marco Liserre
MLMarius Langwasser
Marius Langwasser
The assessment of the state-of-health of power semiconductors and the use of thermal observers rely on precise knowledge of the thermal impedance of the device, which is hard to monitor online with state-of-the-art approaches. This work proposes thermal digital twins, which create a real-time capable digital replica of the physical thermal behavior and enable monitoring the thermal impedance online. The particle swarm optimization (PSO) algorithm and the dual extended Kalman filter (DEKF) are used to extract the thermal model for online monitoring. This is demonstrated for both approaches via a real-time simulation where the reference chip temperature is given by a digital thermal model. A comparison of the approaches is given and the DEKF-based approach is chosen for the implementation of a multi-chip model with thermal cross-coupling. The convergence of the DEKF-based digital twins is experimentally validated in the laboratory.