Emil de Souza Sánchez Filho

Emil de Souza Sánchez Filho

Auto-generated profile, based on publicly available information

Emil de Souza Sánchez Filho

Universidade Federal Fluminense, Brasil

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2008 in Materials Research
Verified
Journal Article
Open access
PDF file
MBMaria Teresa Gomes Barbosa
Maria Teresa Gomes Barbosa
EFEmil de Souza Sánchez Filho
Emil de Souza Sánchez Filho
TOThais Mayra de Oliveira
Thais Mayra de Oliveira
WSWhite José dos Santos
White José dos Santos
The good performance of reinforced concrete structures is ensured by the transfer of stress linking a reinforcing bar and the surrounding concrete. The bond steel-concrete is a very complex phenomenon. This paper presents the experimental results of a program with specimens used in the pull out test with concrete strength of 20, 40, 60, 80 and 100 MPa and four different steel diameters: 12.5, 16.0, 20.0 and 25.0 mm. The test results indicated that the bond stress varied with the bars rib face angle, rib spacing, and rib height. The trends of the results were independent of the concrete strength with the test results, and design recommendations made as regards optimum rib geometries of deformed bars with high bond-slip characteristics

16 August 2013 in Structural Concrete
Verified
Journal Article
Closed access
PDF file
OSOsvaldo Luiz de Carvalho Souza D. Sc.
Osvaldo Luiz de Carvalho Souza D. Sc.
EFEmil de Souza Sánchez Filho
Emil de Souza Sánchez Filho
LVLuiz Eloy Vaz
Luiz Eloy Vaz
JFJúlio Jerônimo Holtz Silva Filho
Júlio Jerônimo Holtz Silva Filho

1 April 2020 in Revista IBRACON de Estruturas e Materiais
Verified
Journal Article
Open access
PDF file
DCD. C. B. Cintra
D. C. B. Cintra
PMP. M. B. Manhães
P. M. B. Manhães
FFFrancisco M. Fernandes
Francisco M. Fernandes
DRDeane Roehl
Deane Roehl
JJJ. T. Araruna Júnior
J. T. Araruna Júnior
EFE. S. Sánchez Filho
E. S. Sánchez Filho
The geometric characterization and evaluation of structural integrity are challenges for the preservation of historical buildings. The challenges are associated to the lack of constructive records, material diversity, access and contact restrictions, and sample extraction. Non-destructive tests are indicated in these cases. The objective of this paper is to evaluate the Ground Penetrating Radar (GPR) technique with 1.2 GHz antenna in the study of the determination of material thickness and discontinuities in the masonry shells of the Theatro Municipal do Rio de Janeiro, a heritage built in early 20th century, with high historical and cultural value. With paintings by renowned artists on their intrados, the domes and vault of brick masonry were at risk of collapse in the 1970s due to differential settlements in the supports and moisture, compromising their paintings. A strengthening intervention was carried out in 1976. Considering the masonry of bricks the main component, the electromagnetic wave propagation velocity was determined as 0,15 m/ns in one of the support walls, allowing to estimate the thicknesses of the elements ranging between 20 and 31 cm. Materials incorporated into the structure were identified: reinforcement, metal inserts and bricks. However, the frequency of the antenna did not allow the detection of damages. The application of the GPR to the characterization of materials and investigation of the integrity of the domes of the Theatro Municipal highlights the potential of this technology to study heritage and other constructions.

1 April 2019 in Revista IBRACON de Estruturas e Materiais
Verified
Journal Article
Open access
PDF file
HHH. L. Herscovici
H. L. Herscovici
DRDeane Roehl
Deane Roehl
EFE. de S. Sánchez Filho
E. de S. Sánchez Filho
This paper presents the results of a test program on 24 concrete beams with a cross section of 15 x 15 cm. Those are divided into two groups of 12 beams. Group I has a steel fiber content of 40 kg/m³ while Group II uses 60 kg/m³ of steel fibers. The tests consider three sets of beam lengths: 300 mm, 500 mm and 800 mm. The beams were submitted to bending aiming at investigating shear stresses, bending, strain energy, toughness, scale effect and fracture energy. Group II showed a slightly higher resistance to rupture than Group I. However, the smaller the length, the larger the influence of the fiber content. The largest fiber content gave the concrete higher resistance when submitted to bending and shear, especially for the smaller lengths. Both strain and fracture energy, however, show considerable differences for smaller lengths, but are almost the same for the 800 mm beams. Toughness shows improvement in the longer beams and a reduction of this property in the shorter beam from Group II.

1 January 2024 in Revista IBRACON de Estruturas e Materiais
Verified
Journal Article
Open access
PDF file
DCDanielli Cristina Borelli Cintra
Danielli Cristina Borelli Cintra
DRDeane Roehl
Deane Roehl
EFEmil de Souza Sánchez Filho
Emil de Souza Sánchez Filho
PLPaulo B. Lourenço
Paulo B. Lourenço
Nuno MendesNuno Mendes
Nuno Mendes
Shell masonry elements, such as vaults and domes represent a widespread structural typology in historic buildings due to their aesthetic grandeur, symbolism, lightness, acoustic efficiency, and structural performance, covering from small to large spans. The study of the behavior of these structures received much interest from remote times to the present, using the most advanced analysis tools available [1 1 A. Tralli, C. Alessandri, and G. Milani, "Computational methods for masonry vaults: A review of recent results," Open Civ. Eng. J., vol. 8, pp. 272–287, 2014, http://dx.doi.org/10.2174/1874149501408010272. http://dx.doi.org/10.2174/18741495014080... ]–[3 3 S. Huerta Fernández, Arcos, Bóvedas y Cúpulas – Geometria y Equilibrio en el Cálculo Tradicional de Estructuras de Fábrica. Madrid: Inst. Juan de Herrera, 2004. ]. One of the main causes of damage to masonry domes and vaults is the differential settlements of the foundations [4 4 S. Acikgoz, K. Soga, and J. Woodhams, "Evaluation of the response of a vaulted masonry structure to differential settlements using point cloud data and limit analyses," Constr. Build. Mater., vol. 150, pp. 916–931, 2017. ], which often come from underground works in the surroundings [5 5 M. D. Boscardin and E. J. Cording, "Building response to excavation-induced settlement," J. Geotech. Eng., vol. 115, pp. 1–21, 1989. ]–[7 7 J. F. T. Jucá, “Influência de escavações nos recalques em edificações vizinhas,” M.S. thesis, Fed. Univ. Rio de Janeiro, Rio de Janeiro, 1981. ]. Monitoring the performance of masonry domes and vaults can contribute to the safety of the building itself, with the conservation of historical and artistic heritage, since they often have works of art integrated on their intrados, can also minimize the costs associated with corrective maintenance, restrictions on the use of the property, and even interdiction time in case of unacceptable safety level or major works. Since historic monuments are tourist attractions, their use and conservation are not only social but also economic demands.

1 October 2016 in Revista IBRACON de Estruturas e Materiais
Verified
Journal Article
Open access
PDF file
MBMaria Teresa Gomes Barbosa
Maria Teresa Gomes Barbosa
EFE. S. Sánchez Filho
E. S. Sánchez Filho
A few international standards regulate the use of the high strength concrete, which may not be adopted generally without consideration of the differences that can be among the materials in different countries. This paper presents the results of an experimental study consisting of pull out tests of Brazilian steel, with five different concrete strengths, 20, 40, 60, 80 and 100 MPa, and three different steel bar diameters, 16.0, 20.0 and 25.0 mm. The experimental results for the bond stress vs. slipping relationship were compared with the provisions of the CEB and with some theoretical formulations found in literature. One statistical analysis is made and equations for predicting the bond stress were derived.