R. Wheadon

R. Wheadon

Auto-generated profile, based on publicly available information

R. Wheadon

INFN Sezione di Torino, via Pietro Giuria 1, Torino, Italy

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2024 in Journal of Instrumentation
Verified
Journal Article
Open access
SAS. Acharya
S. Acharya
RHR. Acosta Hernandez
R. Acosta Hernandez
DAD. Adamová
D. Adamová
AAA. Adler
A. Adler
JAJonatan Adolfsson
Jonatan Adolfsson
NZN. Zurlo
N. Zurlo
A Large Ion Collider Experiment (ALICE) has been conceived and constructed as a heavy-ion experiment at the LHC. During LHC Runs 1 and 2, it has produced a wide range of physics results using all collision systems available at the LHC. In order to best exploit new physics opportunities opening up with the upgraded LHC and new detector technologies, the experiment has undergone a major upgrade during the LHC Long Shutdown 2 (2019–2022). This comprises the move to continuous readout, the complete overhaul of core detectors, as well as a new online event processing farm with a redesigned online-offline software framework. These improvements will allow to record Pb-Pb collisions at rates up to 50 kHz, while ensuring sensitivity for signals without a triggerable signature.

29 August 2024 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Open access
FCFabio Cossio
Fabio Cossio
BAB.R. Achari
B.R. Achari
NAN. Agrawal
N. Agrawal
MAM. Alexeev
M. Alexeev
CAC. Alice
C. Alice
RWR. Wheadon
R. Wheadon

1 July 2024 in Journal of Instrumentation
Verified
Journal Article
Open access
UFU. Follo
U. Follo
GGG. Gioachin
G. Gioachin
CFC. Ferrero
C. Ferrero
Marco MandurrinoMarco Mandurrino
Marco Mandurrino
MBM. Bregant
M. Bregant
RWR. Wheadon
R. Wheadon
In this paper we report on a set of characterisations carried out on the first monolithic LGAD prototype integrated in a customised 110 nm CMOS process having a depleted active volume thickness of 48 μm. This prototype is formed by a pixel array where each pixel has a total size of 100 μm× 250 μm and includes a high-speed front-end amplifier. After describing the sensor and the electronics architecture, both laboratory and in-beam measurements are reported and described. Optical characterisations performed with an IR pulsed laser setup have shown a sensor internal gain of about 2.5. With the same experimental setup, the electronic jitter was found to be between 50 ps and 150 ps, depending on the signal amplitude. Moreover, the analysis of a test beam performed at the Proton Synchrotron (PS) T10 facility of CERN with 10 GeV/c protons and pions indicated that the overall detector time resolution is in the range of 234 ps to 244 ps. Further TCAD investigations, based on the doping profile extracted from C(V) measurements, confirmed the multiplication gain measured on the test devices. Finally, TCAD simulations were used to tune the future doping concentration of the gain layer implant, targeting sensors with a higher avalanche gain. This adjustment is expected to enhance the timing performance of the sensors of the future productions, in order to cope with the high event rate expected in most of the near future high-energy and high-luminosity physics experiments, where the time resolution will be essential to disentangle overlapping events and it will also be crucial for Particle IDentification (PID).

5 August 2025 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Open access
NRN. Rubini
N. Rubini
BAB.R. Achari
B.R. Achari
NAN. Agrawal
N. Agrawal
MAM. Alexeev
M. Alexeev
CAC. Alice
C. Alice
RWR. Wheadon
R. Wheadon

17 August 2024 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Open access
CAChiara Alice
Chiara Alice
BAB.R. Achari
B.R. Achari
NAN. Agrawal
N. Agrawal
MAM. Alexeev
M. Alexeev
PAP. Antonioli
P. Antonioli
RWR. Wheadon
R. Wheadon

1 April 2026 in Journal of Instrumentation
Verified
Journal Article
Open access
PDF file
SGS. Geminiani
S. Geminiani
BAB.R. Achari
B.R. Achari
NAN. Agrawal
N. Agrawal
MAM. Alexeev
M. Alexeev
CAC. Alice
C. Alice
RWR. Wheadon
R. Wheadon
The dual-radiator RICH (dRICH) detector of the ePIC experiment will employ over 300000 SiPM pixels as photosensors, organized into more than 1000 Photon Detection Units. Each PDU is a compact module, approximately 5 × 5 × 12 cm 3 in size, including four custom ASICs connected to 256 SiPMs and an FPGA-based readout card (RDO) responsible for data acquisition and control. Considering the moderately harsh radiation environment expected in the dRICH detector, this study reports on proton irradiation tests performed on key components of the RDO card to assess their tolerance to cumulative Total Ionizing Dose (TID) and Single Event Effects (SEE). All tested components demonstrated radiation tolerance beyond the TID levels expected for the dRICH environment, with the exception of the ATtiny817 microcontroller, which showed destructive failure. Furthermore, as expected, the observed Single Event Upset (SEU) rates call for appropriate mitigation strategies in the final system design.