Fermin Pascual Espino-Cortes

Fermin Pascual Espino-Cortes

Auto-generated profile, based on publicly available information

Fermin Pascual Espino-Cortes

Instituto Politécnico Nacional

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 February 2022
Verified
Book Chapter
Open access
PDF file
LSLuis E. Martínez Santos
Luis E. Martínez Santos
RMRoberto Linares Y Miranda
Roberto Linares Y Miranda
FEFermín P. Espino-Cortés
Fermín P. Espino-Cortés
Historically, the Electromagnetic Compatibility (EMC) began with the disturbances at the radio navigation systems generated by the electrical power distribution lines; hence it was referred to as Radio Interference (RI). This disturbance is an Electromagnetic Interference (EMI). Although this type of EMI has been studied since the first decades of the past century, it still maintains a continued interest of the researchers, especially with the Corona Discharge (CD), generated by High Voltage Direct Current (HVDC) systems. Because of its design criterion and the concern that this phenomenon may affect the new radio communication systems in the very high frequency (VHF), ultra high frequency (UHF), and microwave bands, interest in their studies continues. In this chapter, an analysis of the electromagnetic spectrum of the CD is presented. The CD is generated at a short transmission line located within a semi-anechoic chamber. To be sure of the phenomenon, the CD is identified by its current pulse, which is well studied. The instruments used are an oscilloscope of 2 GHz and 2 GS/s, a spectrum analyzer, and an EMI test receiver. The results show that the CD concentrates its energy at frequencies below 70 MHz. In the UHF band, only narrowband signals very separated were found, with levels that cannot affect radio communication systems.

25 January 2022 in Journal of Nano Research
Verified
Journal Article
Closed access
PDF file
IRIsaias Ramirez-Vazquez
Isaias Ramirez-Vazquez
FEFermin Pascual Espino-Cortes
Fermin Pascual Espino-Cortes
CGCarlos Gómez-Yáñez
Carlos Gómez-Yáñez
Polymer insulators traditionally used in HVAC (High Voltage Alternating Current) are used in HVDC (High Voltage Direct Current) transmission lines. For these polymer insulators, silicone insulating rubber, based on Polydimethylsiloxane (PDMS), is used in industry to manufacture high voltage insulators for power lines. Silicone rubber material ages due to pollution and environmental factors such as UV (ultraviolet light), rain, and temperature. Moreover, no international standard is available to standardize its functional characteristics to ensure its best performance in HVDC regime. Standards usually define the testing procedures to measure the resistance of the materials to these conditions. One of the tests used to evaluate the performance in AC (alternating current) of the housing material of polymeric insulators is the inclined plane test (IPT). This test has the purpose of assessing the tracking and erosion resistance of housing materials. However, for the IPT, no consensus is reached yet for this testing in Direct Current (DC) voltage. In addition, there are no indications whether the formulations that have been successfully used for HVAC work fine; also, in HVDC regime, or not. In this paper, an investigation of the tracking and erosion resistance under positive DC IPT is presented. In this way, the study was carried out on skirts of an HVAC commercial insulator and samples of a new outstanding composite silicone rubber formulation filled with micro and nano particles. The results show that HVAC silicone rubber formulations could not be suitable for HVDC applications under highly polluted conditions. In the case of the new enhanced composite, it is shown how nano particles used in this material significantly enhance the performance during DC tracking and erosion testing well above other materials tested in previous works. Also, thermogravimetric analysis (TGA) of the composites is used to correlate thermal stability with the DC IPT performance.