Simultaneous wireless power and data transfer (SWPDT) is widely investigated because of the increasing requirement for real-time communication between the primary and secondary sides in wireless power transfer systems. This article classifies SWPDT systems into four categories according to the type and number of data channels and data carrier generation method. They are power carrier-based SWPDT system, high-frequency data carrier-based SWPDT system, multiple inductive channels SWPDT system, and inductive–capacitive hybrid channels SWPDT system, respectively. Four key issues, including cross-talk minimization, improvement of signal-to-noise ratio, modulation method for high data rate and low bit error rate, and special design to achieve full-duplex communication and improve misalignment tolerance, are discussed. The advantages, disadvantages, and applications of the four types of SWPDT systems are summarized. Finally, conclusions and outlook of the SWPDT system are given.
31 January 2023 in IEEE Transactions on Power Systems
With the increasing penetration of renewable energy generators, the stability issues of grid-tied converter systems become much more important. However, due to the high nonlinearity and varying damping of converter systems, conventional transient stability analysis methods are not applicable, which may bring to conservativeness or misjudgment on stability assessment. In this paper, the transient stability of grid-tied converter systems with varying damping is investigated to provide stability boundary estimation. Firstly, considering the frequency mutation of the phase-locked loop (PLL) caused by various perturbations, a modified swing equation model of grid-tied converter systems is built, which greatly improves the mathematical model accuracy under transient disturbances. To evaluate the impacts of varying damping and frequency mutation, an iterative equal area criterion (ITEAC) method is proposed with the iterative calculation of the accelerating and decelerating area, which renders stability boundaries with high accuracy. Moreover, the impacts of controller and system parameters on stability boundaries are quantitatively analyzed. Eventually, simulation and hardware-in-loop experiments are performed to verify the effectiveness and superiority of the proposed ITEAC.
28 April 2023 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Microgrid has been rapidly developed for the integration of distributed renewable energy, owing to its superiority of flexible operation and high reliability. Without frequency support from the main grid, the microgrid under islanded operating mode is more likely to lose stability in the presence of large-signal disturbances. However, previous studies mainly focus on weak grid conditions and ignore the interaction effects between different-type converters. Therefore, this paper investigates the transient synchronization stability of an islanded AC microgrid considering dynamic interactions between grid-forming and grid-following converters. Firstly, a simplified nonlinear model of the islanded microgrid is established, which reveals the nonlinear interaction and damping impact on system stability. Based on the passivity principle and LaSalle’s theorem, an explicit stability criterion is formulated to reveal the instability mechanism. With the proposed stability criterion, the impacts of different system parameters are analyzed, which points out the direction of parameters optimization to enhance stability. To validate the effectiveness of the proposed method, simulations and experiments are carried out.
20 February 2023 in IEEE Transactions on Power Electronics
With the rapid development of distributed renewable energy generation and integration, stability issues of power converters systems have been widely studied in recent years. Many previous studies focus on the transient stability of a single converter connected to the weak grid. However, the nonlinear dynamics and stability mechanism of multiple converters systems remain unclear. In this article, a unified nonlinear model of the paralleled-converters system is established, which reveals the interactive power and interactive damping among multiple converters and the weak grid. To analyze the impacts of the interactive power and damping terms on system stability, a dual-iterative equal area criterion (DITEAC) is proposed with a dual-layer iterative calculation of the accelerating area and decelerating area. Compared with the previous studies, the proposed DITEAC method could deal with the nonlinear interactive damping and reduce the conservatism caused by the inequality scaling, which greatly improves the calculation accuracy of stability boundaries. The expansion feasibility of the proposed unified nonlinear model and DITEAC method to the N -converters system is fully discussed. Eventually, simulation and hardware-in-loop experiment results are presented to verify the effectiveness of the proposed method.
10 April 2024 in IEEE Transactions on Power Electronics
The transient instability mechanism and enhanced control for Grid-Forming controlled voltage source converter (GFM-VSC) during voltage sags has been widely investigated. However, the postfault performance are overlooked in the previous studies. In this paper, the postfault transient instability and windup problem of GFM-VSC with virtual inertia is first revealed based on established piecewise nonlinear model and power angle curve. Second, the impact of key parameters on postfault transient stability and windup phenomenon and the impact mechanism is analyzed, revealing that the conventional deceleration effect enhancement method increase the postfault transient stability, but increase the risk of windup problem. Third, the torque error and q -axis voltage feedforward based hybrid synchronization method is adopted to achieve transient stability enhancement and anti-windup. Different from the conventional global deceleration effect enhancement, the adopted control method can inject extra kinetic energy during first current saturation mode and extra damping during current unsaturation state, therefore, the global deceleration effect can be enhanced and the local deceleration effect in the first current saturation period can be deteriorated. Then, the anti-windup and transient stability enhancement is achieved. Finally, the analysis and effectiveness of the designed control strategy has been verified on a 500W experimental prototype.
14 October 2024 in IEEE Transactions on Power Electronics
The current limiter can effectively limit the overcurrent for grid forming (GFM) inverter, but it also makes the inverter easier to lose the stable equilibrium point (SEP) during grid fault. The untimely fault clearing, inaccurate fault depth detection and grid impedance measurement result may lead to overoptimistic deceleration effect evaluation and transient instability problem. In this article, the hybrid power synchronization method is proposed to increase the robustness in transient stability of the GFM inverter against parameters variation. The reactive power that internally related to fault depth is introduced as the dynamic active power reference. It can make sure that the SEP exist during grid fault without the need of fault depth detection. In the same time, the dynamic power compensation related to fault depth is also achieved. The reactive power feedback gain optimization and equivalent power reference limitation method are further given to increase the robustness against large impedance measurement error. Based on equal area criterion, it is demonstrated that with the proposed hybrid power synchronization method, the transient stability of GFM voltage source converter always can be guaranteed once the SEP exists. The impact of line-to-ground fault on transient stability is analyzed and the robust enhanced method is also given. Finally, the effectiveness of the proposed method is verified on a 5 kW experimental platform.