11 August 2020 in Surgical Endoscopy
Background: The laparoscopic approach to liver resection may reduce morbidity and hospital stay. However, uptake has been slow due to concerns about patient safety and oncological radicality. Image guidance systems may improve patient safety by enabling 3D visualisation of critical intra- and extrahepatic structures. Current systems suffer from non-intuitive visualisation and a complicated setup process. A novel image guidance system (SmartLiver), offering augmented reality visualisation and semi-automatic registration has been developed to address these issues. A clinical feasibility study evaluated the performance and usability of SmartLiver with either manual or semi-automatic registration. Methods: Intraoperative image guidance data were recorded and analysed in patients undergoing laparoscopic liver resection or cancer staging. Stereoscopic surface reconstruction and iterative closest point matching facilitated semi-automatic registration. The primary endpoint was defined as successful registration as determined by the operating surgeon. Secondary endpoints were system usability as assessed by a surgeon questionnaire and comparison of manual vs. semi-automatic registration accuracy. Since SmartLiver is still in development no attempt was made to evaluate its impact on perioperative outcomes. Results: The primary endpoint was achieved in 16 out of 18 patients. Initially semi-automatic registration failed because the IGS could not distinguish the liver surface from surrounding structures. Implementation of a deep learning algorithm enabled the IGS to overcome this issue and facilitate semi-automatic registration. Mean registration accuracy was 10.9 ± 4.2 mm (manual) vs. 13.9 ± 4.4 mm (semi-automatic) (Mean difference − 3 mm; p = 0.158). Surgeon feedback was positive about IGS handling and improved intraoperative orientation but also highlighted the need for a simpler setup process and better integration with laparoscopic ultrasound. Conclusion: The technical feasibility of using SmartLiver intraoperatively has been demonstrated. With further improvements semi-automatic registration may enhance user friendliness and workflow of SmartLiver. Manual and semi-automatic registration accuracy were comparable but evaluation on a larger patient cohort is required to confirm these findings.
1 September 2021 in Surgical Oncology
1 October 2015 in International Journal of Surgery
Emergency laparotomy (EL) is a procedure that puts a strain on healthcare resources and is associated with a significant morbidity and mortality. Despite these implications little improvement in the outcome of patients undergoing this procedure has been made in the UK over the last few decades. A delay in transferring patients to theatre has been shown to negatively affect outcome of EL. A prospective case-control study was carried out to evaluate which preoperative factors may contribute towards a delay in theatre transfer. The time between decision to operate and anaesthetic start time was recorded for all patients undergoing EL between April and September 2013 at Gloucestershire Royal Infirmary. Patient selection criteria were based on the National Emergency Laparotomy Audit guidelines. Patients were divided into two groups depending on whether the transfer to theatre was delayed or not. Binary logistic regression analysis was performed on perioperative factors to determine independent predictors of delay. A total of 84 EL were included for analyses with 31 classified as delayed. In the delayed group time for theatre transfer was increased at 6.9 vs. 2.3 h (p < 0.005) respectively. Unavailability of emergency theatres due to other cases taking priority was the most frequent cause for delay (n = 24). On binary logistic regression analysis, indication for laparotomy (OR 4.96, CI 1.4-17.6, p < 0.05), patient age (OR 1.04, CI 1.00-1.07, p < 0.04) and presence of a consultant surgeon (OR 0.16, CI 0.03-0.79, p < 0.03) were found to be independent predictors of delay in EL. In this study, factors that were associated with a delay in commencing EL were operative indication and patient age whereas the presence of a consultant surgeon made a delay less likely. These findings may highlight points of interest for researchers analysing and auditing the provision of EL in the UK.
31 December 2015 in Lasers in Surgery and Medicine
Background Laparoscopic liver ablation therapy can be used for the treatment of primary and secondary liver malignancy. The increased incidence of cancer recurrence associated with this approach, has been attributed to the inability of monitoring the extent of ablated liver tissue. Methods The feasibility of assessing liver ablation with probe-based confocal laser endomicroscopy (CLE) was studied in a porcine model of laparoscopic microwave liver ablation. Following the intravenous injection of the fluorophores fluorescein and indocyanine green, CLE images were recorded at 488 nm and 660 nm wavelength and compared to liver histology. Statistical analysis was performed to assess if fluorescence intensity change can predict the presence of ablated liver tissue. Results CLE imaging of fluorescein at 488 nm provided good visualization of the hepatic microvasculature; whereas, CLE imaging of indocyanine green at 660 nm enabled detailed visualization of hepatic sinusoid architecture and interlobular septations. Fluorescence intensity as measured in relative fluorescence units was found to be 75–100% lower in ablated compared to healthy liver regions. General linear mixed modeling and ROC analysis found the decrease in fluorescence to be statistically significant. Conclusion Laparoscopic, dual wavelength CLE imaging using two different fluorophores enables clinically useful visualization of multiple liver tissue compartments, in greater detail than is possible at a single wavelength. CLE imaging may provide valuable intraoperative information on the extent of laparoscopic liver ablation. Lasers Surg. Med. 48:299–310, 2016. © 2015 The Authors. Lasers in Surgery and Medicine Published by Wiley Periodicals, Inc.
19 December 2016 in Lasers in Surgery and Medicine
Metastasis of colorectal cancer to the liver is the most common indication for hepatic resection in a western population. Incomplete excision of malignancy due to residual microscopic disease normally results in worse patient outcome. Therefore, a method aiding in the real time discrimination of normal and malignant tissue on a microscopic level would be of benefit. The ability of fluorescent probe-based confocal laser endomicroscopy (pCLE) to identify normal and malignant liver tissue was evaluated in an orthotopic murine model of colorectal cancer liver metastasis (CRLM). To maximise information yield, two clinical fluorophores, fluorescein and indocyanine green (ICG) were injected and imaged in a dual wavelength approach (488 and 660 nm, respectively). Visual tissue characteristics on pCLE examination were compared with histological features. Fluorescence intensity in both tissues was statistically analysed to elucidate if this can be used to differentiate between normal and malignant tissue. Fluorescein (488 nm) enabled good visualisation of normal and CRLM tissue, whereas ICG (660 nm) visualisation was limited to normal liver tissue only. Fluorescence intensity in areas of CRLM was typically 53–100% lower than normal hepatic parenchyma. Using general linear mixed modelling and receiver operating characteristic analysis, high fluorescence intensity was found to be statistically more likely in normal hepatic tissue. Real time discrimination between normal liver parenchyma and metastatic tissue with pCLE examination of fluorescein and ICG is feasible. Employing two (rather than a single) fluorophores allows a combination of qualitative and quantitative characteristics to be used to distinguish between hepatic parenchyma and CRLM. Lasers Surg. Med.
1 December 2014 in International Journal of Surgery
To evaluate predictors of allogenic blood transfusion requirements in patients undergoing minimal invasive oesophagectomy at a tertiary high volume centre for oesophago-gastric surgery. Retrospective analysis of all patients undergoing minimal access oesophagectomy in our department between January 2010 and December 2011. Patients were divided into two groups depending on whether they required a blood transfusion at any time during their index admission. Factors that have been shown to influence perioperative blood transfusion requirements in major surgery were included in the analysis. Binary logistic regression analysis was performed to determine the impact of patient and perioperative characteristics on transfusion requirements during the index admission. A total of 80 patients underwent minimal access oesophagectomy, of which 61 patients had a laparoscopic assisted oesophagectomy and 19 patients had a minimal invasive oesophagectomy. Perioperative blood transfusion was required in 28 patients at any time during hospital admission. On binary logistic regression analysis, a lower preoperative haemoglobin concentration (p < 0.01), suffering a significant complication (p < 0.005) and laparoscopic assisted oesophagectomy (p < 0.05) were independent predictors of blood transfusion requirements. It has been reported that requirement for blood transfusion can affect long-term outcomes in oesophageal cancer resection. Two factors which could be addressed preoperatively; haemoglobin concentration and type of oesophageal resection, may be valuable in predicting blood transfusions in patients undergoing minimally invasive oesophagectomy. Our analysis revealed that preoperative haemoglobin concentration, occurrence of significant complications and type of minimal access oesophagectomy predicted blood transfusion requirements in the patient population examined.