Asitha L. Kulasekera

Asitha L. Kulasekera

Auto-generated profile, based on publicly available information

Asitha L. Kulasekera

Department of Mechanical Engineering, University of Moratuwa, Moratuwa, Sri Lanka

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2011
Verified
Conference Paper
Closed access
AKA.L. Kulasekera
A.L. Kulasekera
RGRuwan Gopura
Ruwan Gopura
KHKTMU Hemapala
KTMU Hemapala
NPN. Perera
N. Perera
The application of Multi-Agent Systems (MAS) in electrical power systems are becoming popular due to their inherent benefits such as increased autonomy, reactivity, proactivity and social ability. This paper reviews current research on the application of multi-agent systems in microgrid schemes. The paper is mainly focused on recent developments of multi-agent systems in different aspects of microgrids such as control, market modeling, optimization and power restoration. The future directions of multi-agent systems in microgrid applications are also discussed briefly. Furthermore, this review is concluded by discussing the development of an enhanced multi-agent based distributed control framework for microgrids.

1 May 2020
Verified
Conference Paper
Closed access
WAW.V.I. Awantha
W.V.I. Awantha
AWA.T. Wanasinghe
A.T. Wanasinghe
AKA.G.P. Kavindya
A.G.P. Kavindya
AKA.L. Kulasekera
A.L. Kulasekera
DCDamith Chathuranga
Damith Chathuranga
The following paper presents the concept of a layer jamming based soft glove for hand tremor suppression, its implementation, validation of the soft glove for hand tremor suppression and evaluation of the effect of layer jamming actuator placement. Wearable tremor suppression devices can avoid the side effects which occur due to available medical treatments, but contemporary methods are bulky and negatively affects the voluntary motions of the hand. Hence, a soft tremor suppression device can be developed to overcome the issues faced in contemporary wearable devices. A hand tremor suppression device using layer jamming was proposed in the study. In this study, experimentation for the material selection for layer jamming elements, evaluation of the layer jamming element placement and validation of the soft glove were conducted to characterize and evaluate the performance of the soft glove. Layer jamming material selection was done by measuring the deflection against an applied load. The performance of the soft glove was evaluated by measuring the suppression of a simulated tremor for the dorsal and palmar configurations. Performance evaluation shows a maximum tremor reduction of 78.32% in the palmar side element configuration in comparison to 38.23% in the dorsal side. Performance evaluation shows promising results in the suppression of hand tremors using the proposed soft glove and the results suggest that the palmar side element configuration can achieve higher tremor reduction comparatively.

14 December 2021 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Open access
AWA. T. Wanasinghe
A. T. Wanasinghe
WAW. V. I. Awantha
W. V. I. Awantha
AKA. G. P. Kavindya
A. G. P. Kavindya
AKA. L. Kulasekera
A. L. Kulasekera
DCD. S. Chathuranga
D. S. Chathuranga
BSB. Senanayake
B. Senanayake
Tremors are a common movement disorder that affects a person’s life adversely. With various drawbacks of current treatment methods, there is a need for a mechanical solution. The authors present a soft orthosis based on layer jamming for the suppression of hand tremors. A vacuum supplied to the layer jamming elements which contain a stack of layers attached to the glove leads to increased stiffness in the glove, suppressing the tremor. The behavior of the tremor in a cohort of patients in Sri Lanka was studied and showed that the tremor’s mean frequency was 5.05 ± 2.03 Hz. An existing analytical model was modified and verified experimentally to select the layer jamming element. An element with sandpaper (320 grade) and tracing paper was chosen based on the high stiffness provided at a lower weight (total weight of the glove = 30g). Experimental results show minimal variation in stiffness for vacuum pressures between 10-50 kPa (abs.). The performance evaluation on a test rig was used to verify the efficacy of the glove and showed optimal placement on the palmar side with a mean tremor amplitude reduction of 78.32%. Clinical trials conducted on 11 recruited tremor patients showed a mean frequency power reduction of 41.74 ± 12.11%, 41.99 ± 14.82%, and 24.71 ± 12.18% in the index and middle fingers and in grasping, respectively with a maximum power reduction of 59.15%. The soft, low weight orthosis shows a high tremor suppression in both the test rig and clinical experiments.

20 August 2021 in IEEE Access
Verified
Journal Article
Open access
AKAsitha L. Kulasekera
Asitha L. Kulasekera
RARancimal B. Arumathanthri
Rancimal B. Arumathanthri
DCDamith S. Chathuranga
Damith S. Chathuranga
RGR. A. R. C. Gopura
R. A. R. C. Gopura
TLThilina Lalitharatne
Thilina Lalitharatne
Muscle weakness owing to stroke, spinal cord injuries, or aging can make a person’s life sedentary, temporarily as well as permanently. Such persons need to be motivated to break their sedentary postures and attempt independent motion. A key motivator in this aspect is the ability to easily transition from seated to standing posture. If this sit-to-stand transition (STSt) is easy, it will encourage further mobility. A soft wearable device that can assist the STSt, would fill this need perfectly. Such a device should be able to seamlessly assist during STSt and be unobtrusive during sitting. A major limitation that is currently holding back the development of soft exosuits in STSt-assist is the lack of low-profile soft actuators with high strain rate and force-to-weight ratio. Hence, we propose a novel low-profile vacuum actuator (LPVAc) with an integrated inductive displacement sensor that, can be rapidly fabricated, is lightweight (14g), and can provide high strain (65%) and a high force-to-weight ratio (285 times self-weight). The proposed actuator comprises a low-profile spring encased within a low-density polyethylene film with rapid vacuum actuation and passive quick return. The proposed inductive sensor has a sensitivity of $0.0022~\mu H/mm$ and the hysteresis is below 1.5% with an overall absolute average error percentage of 5.24%. The performance of the proposed integrated sensor in displacement control of the LPVAc is experimentally evaluated. The proposed actuator is integrated into a novel mono-articular STSt-assist exosuit for preliminary testing. Surface electromyography measurements of the gluteus maximus muscles during STSt indicate a mean muscle activity reduction of 45%. This supports the potential use of the proposed actuator in STSt-assist.

1 May 2020
Verified
Conference Paper
Closed access
AKAsitha L. Kulasekera
Asitha L. Kulasekera
RARancimal B. Arumathanthri
Rancimal B. Arumathanthri
DCDamith Chathuranga
Damith Chathuranga
TLThilina D. Lalitharatne
Thilina D. Lalitharatne
RGRuwan Gopura
Ruwan Gopura
Muscle weakness following a stroke, spinal cord injuries or age can make people sedentary temporarily or permanently. The best strategy for such patients’ recovery is to motivate them to break their wheel/chair bound condition and attempt independent motion. The ability to easily transition from sit-to-stand (STS) would encourage further mobility. Hence, there is a need for wearable assist devices that seamlessly assists STS transition. Such a device should be non-obstructive during the seated phase and assist during STS. Soft exosuits are advantageous over conventional rigid exoskeletons in this context. The use of exosuits in STS assistance is currently limited by the lack of low-profile soft actuators with high strain rate and force-to-weight ratio. Hence, we propose a novel low-profile vacuum actuator that, can be rapidly fabricated, is lightweight (14g), and can provide high strain ($\sim 65$%) and a high force-to-weight ratio $(\sim 160)$. The proposed actuator comprises a low-profile spring encased within a low-density polyethylene film with rapid vacuum actuation and passive quick return. The applicability of the proposed actuator in assisting STS is preliminarily studied via a prototype exosuit. Surface electromyography (sEMG) measurements of the gluteus maximus (GM) muscles during STS experimentally show the potential use of the proposed actuator in an STS-assist exosuit. Experimental sEMG results indicate a mean reduction of $\sim 46$% muscle activity of GM muscle during STS.

1 October 2017
Verified
Conference Paper
Closed access
LML. S. R. Mechsy
L. S. R. Mechsy
MDM. U. B. Dias
M. U. B. Dias
WPW. Pragithmukar
W. Pragithmukar
AKA. L. Kulasekera
A. L. Kulasekera