5 March 2019 in IEEE Transactions on Instrumentation and Measurement
24 August 2020 in IEEE Transactions on Instrumentation and Measurement
The Wiener-Hammerstein (W-H) system is the most popular type of Volterra nonlinear dynamical system. It is a combination of two dynamical sub-systems, separated by a static nonlinearity. The best linear approximation (BLA) technique assembles two linear filters and the nonlinearity into a single filter for input and output. The main identification challenge resides in separating two filters. This work proposes an iterative Random Forest (RF) as an alternative to select the dynamics combinatorially. It is like the iterative selection of holiday destinations based on the recommendations of random travellers. The proposed technique supports reasonably high noise level and requires the optimization of a single model. Thus, a speedup in processing time is achieved without any prior knowledge about the model configuration both on simulated examples and benchmark data.
13 January 2017 in The Journal of Supercomputing
6 February 2021 in Engineering, Technology & Applied Science Research
Parallel connected inverters in islanded mode, are getting momentous attention due to their ability to increase the power distribution and reliability of a power system. When there are different ratings of Distributed Generation (DG) units, they will operate in parallel connection due to different output voltages, impedance mismatch, or different phase that can cause current to flow between DG units. The magnitude of this circulating current sometimes can be very large and damage the DG inverters and also cause power losses that affect power-sharing accuracy, power quality, and the efficiency of the Microgrid (MG) system. Droop control, improved droop control, and virtual impedance control techniques and modifications in the virtual impedance control technique are widely used to suppress the circulating current. However, the addition of the virtual impedance to each inverter to compensate the output impedance is resistive or inductive in nature. The resistive nature of the output impedance always causes a certain voltage drop, whereas the inductive nature of the output impedance causes phase delay for the output voltage. Both problems are addressed by the proposed control mechanism in this paper. Negative resistance, along with virtual impedance, is utilized in the proposed control strategy. The output impedance is to be maintained as inductive in nature to achieve good load sharing in droop control MGs. The simulation results validate the proposed control scheme.