Michael E. Andrew

Michael E. Andrew

Auto-generated profile, based on publicly available information

Michael E. Andrew

Bioanalytics Branch, Health Effects Laboratory Division, National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, Morgantown, WV, USA

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2013 in Particle and Fibre Toxicology
Verified
Journal Article
Open access
PDF file
RMRobert R Mercer
Robert R Mercer
JSJames F Scabilloni
James F Scabilloni
AHAnn F Hubbs
Ann F Hubbs
LBLori A Battelli
Lori A Battelli
WMWalter McKinney
Walter McKinney
DPDale W Porter
Dale W Porter
Prior studies have demonstrated a rapid and progressive acute phase response to bolus aspiration of multi-walled carbon nanotubes (MWCNTs). In this study we sought to test the hypothesis that inhalation exposure to MWCNT produces a fibrotic response and that the response is chronically persistent. To address the hypothesis that inhaled MWCNTs cause persistent morphologic changes, male C57BL/6 J mice were exposed in a whole-body inhalation system to a MWCNT aerosol and the fibrotic response in the alveolar region examined at up to 336 days after termination of exposure.

23 March 2016 in American Journal of Criminal Justice
Verified
Journal Article
Closed access
PDF file
JVJohn M. Violanti
John M. Violanti
DFDesta Fekedulegn
Desta Fekedulegn
THTara A. Hartley
Tara A. Hartley
LCLuenda Charles
Luenda Charles
MAMichael E. Andrew
Michael E. Andrew
CBCecil M. Burchfiel
Cecil M. Burchfiel

Verified
Journal Article
Open access
PDF file
PSPhoebe Stapleton
Phoebe Stapleton
VMValerie C. Minarchick
Valerie C. Minarchick
ACAmy M. Cumpston
Amy M. Cumpston
WMWalter McKinney
Walter McKinney
BCBean T. Chen
Bean T. Chen
TNTimothy R. Nurkiewicz
Timothy R. Nurkiewicz
Engineered nanomaterials have been developed for widespread applications due to many highly unique and desirable characteristics. The purpose of this study was to assess pulmonary inflammation and subepicardial arteriolar reactivity in response to multi-walled carbon nanotube (MWCNT) inhalation and evaluate the time course of vascular alterations. Rats were exposed to MWCNT aerosols producing pulmonary deposition. Pulmonary inflammation via bronchoalveolar lavage and MWCNT translocation from the lungs to systemic organs was evident 24 h post-inhalation. Coronary arterioles were evaluated 24–168 h post-exposure to determine microvascular response to changes in transmural pressure, endothelium-dependent and -independent reactivity. Myogenic responsiveness, vascular smooth muscle reactivity to nitric oxide, and α-adrenergic responses all remained intact. However, a severe impact on endothelium-dependent dilation was observed within 24 h after MWCNT inhalation, a condition which improved, but did not fully return to control after 168 h. In conclusion, results indicate that MWCNT inhalation not only leads to pulmonary inflammation and cytotoxicity at low lung burdens, but also a low level of particle translocation to systemic organs. MWCNT inhalation also leads to impairments of endothelium-dependent dilation in the coronary microcirculation within 24 h, a condition which does not fully dissipate within 168 h. The innovations within the field of nanotechnology, while exciting and novel, can only reach their full potential if toxicity is first properly assessed.

8 April 2019 in Policing: An International Journal
Verified
Journal Article
Closed access
JVJohn M. Violanti
John M. Violanti
SOSherry L. Owens
Sherry L. Owens
EMErin McCanlies
Erin McCanlies
DFDesta Fekedulegn
Desta Fekedulegn
MAMichael E. Andrew
Michael E. Andrew
Purpose: The purpose of this paper is to provide a review of law enforcement suicide research from 1997 to 2016.Design/methodology/approach: The PRISMA systematic review methodology was implemented. A SCOPUS search identified a total of 97 documents. After applying all exclusion criteria, the results included a list of 44 articles in the review.Findings: Overall, studies investigating law enforcement suicide rates show conflicting results, with some studies showing lower suicide rates among law enforcement, some showing higher rates, and some showing no difference to comparison populations. Recurring research themes were lack of an appropriate comparison group, and small statistical power, particularly for minority and female officers. Stressors related to suicide among police included lack of organizational support, traumatic events, shift work, stigma associated with asking for help, or problems associated with fitting in with the police culture. Problems associated with domestic relationships and alcohol use were commonly mentioned as precursors to suicide or as correlates of suicidal ideation and were hypothesized to arise from stressful working conditions.Research limitations/implications: Some limitations in law enforcement suicide research include the lack of theory, under-reporting of suicides, and guarded survey responses from police officers. Future directions in police suicide research include investigating etiological factors such as past adverse life and family experiences, social-ecological variation in suicide, or differences in suicide rates within the law enforcement occupation.Practical implications: Police work, given chronic and traumatic stress, lack of support, danger, and close public scrutiny is a fertile occupation for increased suicide risk. Awareness of the scope of the problem and associated risk factors can help to initiate prevention programs.Originality/value: This paper provides a long-term review of literature regarding police suicidality, with suggestions for research and prevention.

1 January 2017 in Psychoneuroendocrinology
Verified
Journal Article
Closed access
JVJohn M. Violanti
John M. Violanti
DFDesta Fekedulegn
Desta Fekedulegn
MAMichael E. Andrew
Michael E. Andrew
THTara A. Hartley
Tara A. Hartley
LCLuenda Charles
Luenda Charles
CBCecil M. Burchfiel
Cecil M. Burchfiel

1 December 2015 in Particle and Fibre Toxicology
Verified
Journal Article
Open access
PDF file
JSJennifer D. Sisler
Jennifer D. Sisler
RLRuibin Li
Ruibin Li
WMWalter McKinney
Walter McKinney
RMRobert R. Mercer
Robert R. Mercer
ZJZhaoxia Ji
Zhaoxia Ji
YQYong Qian
Yong Qian
Although classified as metal oxides, cobalt monoxide (CoO) and lanthanum oxide (La2O3) nanoparticles, as representative transition and rare earth oxides, exhibit distinct material properties that may result in different hazardous potential in the lung. The current study was undertaken to compare the pulmonary effects of aerosolized whole body inhalation of these nanoparticles in mice. Mice were exposed to filtered air (control) and 10 or 30 mg/m3 of each particle type for 4 days and then examined at 1 h, 1, 7 and 56 days post-exposure. The whole lung burden 1 h after the 4 day inhalation of CoO nanoparticles was 25 % of that for La2O3 nanoparticles. At 56 days post exposure, < 1 % of CoO nanoparticles remained in the lungs; however, 22–50 % of the La2O3 nanoparticles lung burden 1 h post exposure was retained at 56 days post exposure for low and high exposures. Significant accumulation of La2O3 nanoparticles in the tracheobronchial lymph nodes was noted at 56 days post exposure. When exposed to phagolysosomal simulated fluid, La nanoparticles formed urchin-shaped LaPO4 structures, suggesting that retention of this rare earth oxide nanoparticle may be due to complexation of cellular phosphates within lysosomes. CoO nanoparticles caused greater lactate dehydrogenase release in the bronchoalveolar fluid (BALF) compared to La2O3 nanoparticles at 1 day post exposure, while BAL cell differentials indicate that La2O3 nanoparticles generated more inflammatory cell infiltration at all doses and exposure points. Histopathological analysis showed acute inflammatory changes at 1 day after inhalation of either CoO or La2O3 nanoparticles. Only the 30 mg/m3 La2O3 nanoparticles exposure caused chronic inflammatory changes and minimal fibrosis at day 56 post exposure. This is in agreement with activation of the NRLP3 inflammasome after in vitro exposure of differentiated THP-1 macrophages to La2O3 but not after CoO nanoparticles exposure. Taken together, the inhalation studies confirmed the trend of our previous sub-acute aspiration study, which reported that CoO nanoparticles induced more acute pulmonary toxicity, while La2O3 nanoparticles caused chronic inflammatory changes and minimal fibrosis.