Patrick M. Kane

Patrick M. Kane

Auto-generated profile, based on publicly available information

Patrick M. Kane

Philadelphia Hand to Shoulder Center, Department of Orthopedic Surgery, Thomas Jefferson University, Philadelphia, Pennsylvania

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 May 2020 in Current Reviews in Musculoskeletal Medicine
Verified
Journal Article
Closed access
PDF file
MNMichael N. Nakashian
Michael N. Nakashian
DIDanielle Ireland
Danielle Ireland
PKPatrick M. Kane
Patrick M. Kane

1 August 2014 in Clinical Orthopaedics and Related Research
Verified
Journal Article
Closed access
PDF file
PKPatrick Kane
Patrick Kane
BVBryan Vopat
Bryan Vopat
WHWendell Heard
Wendell Heard
NTNikhil Thakur
Nikhil Thakur
DPDavid Paller
David Paller
CBChristopher Born
Christopher Born
Intertrochanteric hip fractures pose a significant challenge for the orthopaedic community as optimal surgical treatment continues to be debated. Currently, varus collapse with lag screw cutout is the most common mode of failure. Multiple factors contribute to cutout. From a surgical technique perspective, a tip apex distance less than 25 mm has been suggested to decrease the risk of cutout. We hypothesized that a low-center lag screw position in the femoral head, with a tip apex distance greater than 25 mm will provide equal, if not superior, biomechanical stability compared with a center-center position with a tip apex distance less than 25 mm in an unstable intertrochanteric hip fracture stabilized with a long cephalomedullary nail. We attempted to examine the biomechanical characteristics of intertrochanteric fractures instrumented with long cephalomedullary nails with two separate lag screw positions, center-center and low-center. Our first research purpose was to examine if there was a difference between the center-center and low-center groups in cycles to failure and failure load. Second, we analyzed if there was a difference in fracture translation between the study groups during loading. Nine matched pairs of femurs were assigned to one of two treatment groups: low-center lag screw position and center-center lag screw position. Cephalomedullary nails were placed and tip apex distance was measured. A standard unstable four-part intertrochanteric fracture was created in all samples. The femurs were loaded dynamically until failure. Cycles to failure and load and displacement data were recorded, and three-dimensional (3-D) motion was recorded using an Optotrak® motion tracking system. There were no significant differences between the low-center and center-center treatment groups regarding the mean number of cycles to failure and mean failure load. The 3-D kinematic data showed significantly increased motion in the center-center group compared with the low-center group. At the time of failure, the magnitude of fracture translation was statistically significantly greater in the center-center group (20 ± 2.8 mm) compared with the low-center group (15 ± 3.4 mm; p = 0.004). Additionally, there was statistically significantly increased fracture gap distraction (center-center group, 13 ± 2.8 versus low-center group, 7 ± 4; p < 0.001) and shear fracture gap translation (center-center group, 12 ± 2.3 mm; low-center group, 6 ± 2.7 mm; p < 0.001). Positioning of the lag screw inferior in the head and neck was found to be at least as biomechanically stable as the center-center group although the tip apex distance was greater than 25 mm. Our findings challenge previously accepted principles of optimal lag screw placement.

3 October 2018 in Journal of Bone and Joint Surgery
Verified
Journal Article
Closed access
MGMichael P. Gaspar
Michael P. Gaspar
EPEmily M. Pflug
Emily M. Pflug
AAAlexander J. Adams
Alexander J. Adams
SJSidney M. Jacoby
Sidney M. Jacoby
ESEon K. Shin
Eon K. Shin
PKPatrick M. Kane
Patrick M. Kane
Background: Although orthopaedic surgeons have been shown to prescribe excessive amounts of opioid analgesics postoperatively, the degree in which surgical trainees contribute to this trend is unknown. The purpose of this study was to compare self-reported opioid-prescribing behavior, factors influencing this behavior, and perceptions of patient opioid utilization and disposal between hand surgeons and trainees. Methods: Attending hand surgeons and trainees in hand, orthopaedic, and plastic surgery programs were invited to participate in a web-based survey including demographic characteristics; self-reported prescribing behavior specific to 4 procedures: open carpal tunnel release, trigger finger release, thumb carpometacarpal arthroplasty, and distal radial fracture open reduction and internal fixation; and perceptions and influencing factors. Analgesic medications were converted to morphine milligram equivalents and were compared across groups of interest using independent t tests or analysis of variance for each procedure. Results: A total of 1,300 respondents (266 attending surgeons, 98 fellows, 708 orthopaedic residents, and 228 plastic surgery residents) were included. Surgeons reported prescribing fewer total morphine milligram equivalents compared with residents for all 4 procedures. Personal experience was the most influential factor for prescribing behavior by surgeons and fellows. Although residents reported that attending surgeon preference was their greatest influence, most reported no direct opioid-related communication with attending surgeons. Conclusions: Residents self-report prescribing significantly higher morphine milligram equivalents for postoperative analgesia following commonly performed hand and wrist surgical procedures than attending surgeons. Poor communication between residents and attending surgeons may contribute to this finding. Residents may benefit from education on opioid prescription, and training programs should encourage direct communication between trainees and attending surgeons.

1 December 2014 in Journal of Orthopaedic Trauma
Verified
Journal Article
Closed access
PKPatrick Kane
Patrick Kane
BVBryan Vopat
Bryan Vopat
DPDavid Paller
David Paller
SKSarath Koruprolu
Sarath Koruprolu
ADAlan H. Daniels
Alan H. Daniels
CBChristopher Born
Christopher Born
Objectives: This study compared the torsional properties of stable intertrochanteric femur fractures in a cadaveric bone model using 2 different distal fixation strategies: unlocked long cephalomedullary nailing versus dynamically locked nailing. Methods: Fourteen matched pairs of cadaveric femora were randomly assigned to 1 of 2 distal fixation treatment groups: a single distal interlock screw placed in the dynamic orientation or no distal screw fixation. A stable 2-part intertrochanteric fracture was produced. Specimens were potted and mounted in a double gimbal fixture, facilitating unconstrained motion in the sagittal and coronal planes. Specimens were cyclically loaded dynamically in both internal and external rotation. Range of motion, internal and external rotation stiffness, torsion stiffness, torsion yield, and ultimate torsion magnitude were calculated. Results: The samples instrumented with a distal locking screw reported statistically significantly greater internal (1.54 ± 0.81 N·m per degree vs. 1.08 ± 0.35 N·m per degree; P = 0.026) and external rotational stiffness (1.42 ± 0.72 N·m per degree vs. 0.86 ± 0.36 N·m per degree; P = 0.009). Samples with locked distal fixation were statistically stiffer and displayed statistically less displacement at the yield and peak torque. The yield torque was statistically significantly higher in the samples without distal fixation (14.2 ± 3.3 N·m per degree vs. 10.6 ± 3.8 N·m per degree; P = 0.037). The peak torque was comparable between locked and unlocked samples (15.0 ± 4.6 N·m per degree vs. 16.2 ± 4.2 N·m per degree; P = 0.492). Conclusions: Distal locking of femoral intramedullary nails increases the stiffness of the nail–femur construct. Unlocked samples displayed statistically significant higher yield torque while maintaining comparable peak torque as the locked samples. This study indicates that treating stable intertrochanteric fractures with unlocked long intramedullary nails may be an acceptable option, although further clinical study will be needed to test this assertion.

7 March 2018 in Journal of Bone and Joint Surgery
Verified
Journal Article
Closed access
MGMichael P. Gaspar
Michael P. Gaspar
JAJulie E. Adams
Julie E. Adams
RZRalph C. Zohn
Ralph C. Zohn
SJSidney M. Jacoby
Sidney M. Jacoby
RCRandall W. Culp
Randall W. Culp
PKPatrick M. Kane
Patrick M. Kane
Background: The purpose of this study was to report our long-term outcomes following reconstruction of the forearm interosseous membrane (IOM) with bone-patellar tendon-bone (BPTB) graft for treatment of chronic Essex-Lopresti injuries. Methods: We identified 33 patients who underwent IOM reconstruction with BPTB graft for chronic Essex-Lopresti injuries over a 20-year treatment interval. Twenty male and 13 female patients, with a mean age of 42.1 years (range, 19 to 73 years) and a minimum follow-up interval of 5 years, were included. Preinjury clinical examination and radiographic measurements were obtained from records for comparison with prospectively collected data. Additional functional outcome data collected postoperatively included QuickDASH (an abbreviated version of the Disabilities of the Arm, Shoulder and Hand [DASH]), modified Mayo wrist (MMW), and Broberg-Morrey elbow function scores. Results: IOM reconstruction was performed at a mean interval (and standard deviation) of 44.9 ± 60.0 months (range, 6.4 to 208 months) from the time of the initial injury. At a mean follow-up of 10.9 ± 4.4 years (range, 5.5 to 24.2 years), significant improvements were observed in mean elbow flexion-extension arc (+13° [95% confidence interval (CI), 4° to 22°]; p = 0.005), wrist flexion-extension arc (+19° [95% CI, 4° to 34°]; p = 0.016), forearm pronation-supination (+23° [95% CI, 8° to 39°]; p = 0.004), and grip strength (+25% of that of the contralateral side [95% CI, 18% to 32% of contralateral side]; p < 0.001). Improvements in ulnar variance were sustained over the long term from +3.9 mm (95% CI, 3.2 to 4.6 mm) preoperatively to −1.6 mm (95% CI, −2.3 to −0.9 mm) immediately postoperatively and −1.1 mm (95% CI, −1.8 to −0.4 mm) at the time of the final follow-up (p < 0.001). The mean QuickDASH, MMW, and Broberg-Morrey scores were 29.8 (range, 5 to 61), 82.7 (range, 60 to 100), and 91.6 (range, 64 to 100), respectively. Conclusions: IOM reconstruction with a BPTB graft is an effective treatment option for chronic Essex-Lopresti injuries, with satisfactory clinical and functional outcomes over the long term. Level of Evidence: Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.

12 August 2015 in SpringerPlus
Verified
Journal Article
Open access
PDF file
BVBryan G Vopat
Bryan G Vopat
PKPatrick M Kane
Patrick M Kane
PMP Kaveh Mansuripur
P Kaveh Mansuripur
DPDavid Paller
David Paller
SKSarath Koruprolu
Sarath Koruprolu
CBChristopher T Born
Christopher T Born
Many surgeons currently use long cephomedullary nails for the treatment of intertrochanteric fractures. The optimal indications for deploying distal interlocks are still debatable. This study examined the torsional biomechanical properties of 3-part intertrochanteric femur fractures in a cadaveric bone model using two different distal fixation strategies, an unlocked long cephalomedullary nail versus a dynamically locked nail. Our hypothesis is that a long cephalomedullary nail does not require distal locking fixation when used for treatment of a 3-part intertrochanteric fracture. Five matched pairs of cadaveric femora were randomly assigned to one of two distal fixation treatment groups; a single distal interlock screw placed in the dynamic orientation or no distal fixation. A 3-part intertrochanteric fracture was produced. Specimens were potted and mounted in a double gimbal fixture facilitating unconstrained motion in the sagittal and coronal planes. Specimens were cyclically loaded dynamically in both internal and external rotation. Range of motion, internal and external rotation stiffness, torsion stiffness, torsion yield and ultimate torsion magnitude were calculated. The samples instrumented with a distal locking screw reported statistically greater external rotational stiffness than the unlocked samples in nondestructive testing. The results of the destructive data demonstrated no statistical difference between the locked and unlocked group with regard to yield torque (p = 0.282), peak torque (p = 0.340), stiffness (p = 0.220), displacement at yield torque (p = 0.0605), and displacement at peak torque (p = 0.280). Distal locking of a long cephalomedullary nail increases the stiffness of the nail-femur construct in a 3-part biomechanical fracture model. However, our testing illustrates that an unlocked construct will tolerate at least equal stress before catastrophic failure in a torsional loading model.