Jian Gao

Jian Gao

Auto-generated profile, based on publicly available information

Jian Gao

Purdue University, West Lafayette, IN

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 May 2013 in Applied Optics
Verified
Journal Article
Closed access
PDF file
DGDaniel R. Guildenbecher
Daniel R. Guildenbecher
JGJian Gao
Jian Gao
PRPhillip L. Reu
Phillip L. Reu
JCJun Chen
Jun Chen
The accuracy of digital in-line holography to detect particle position and size within a 3D domain is evaluated with particular focus placed on detection of nonspherical particles. Dimensionless models are proposed for simulation of holograms from single particles, and these models are used to evaluate the uncertainty of existing particle detection methods. From the lessons learned, a new hybrid method is proposed. This method features automatic determination of optimum thresholds, and simulations indicate improved accuracy compared to alternative methods. To validate this, experiments are performed using quasi-stationary, 3D particle fields with imposed translations. For the spherical particles considered in experiments, the proposed hybrid method resolves mean particle concentration and size to within 4% of the actual value, while the standard deviation of particle depth is less than two particle diameters. Initial experimental results for nonspherical particles reveal similar performance.

28 October 2013 in Optics Express
Verified
Journal Article
Open access
PDF file
JGJian Gao
Jian Gao
DGDaniel R. Guildenbecher
Daniel R. Guildenbecher
PRPhillip L. Reu
Phillip L. Reu
Jun ChenJun Chen
Jun Chen
Optics InfoBase is the Optical Society's online library for flagship journals, partnered and copublished journals, and recent proceedings from OSA conferences.

24 May 2013 in Optics Letters
Verified
Journal Article
Closed access
PDF file
JGJian Gao
Jian Gao
DGDaniel R. Guildenbecher
Daniel R. Guildenbecher
PRPhillip L. Reu
Phillip L. Reu
VKVarun Kulkarni
Varun Kulkarni
PSPaul E. Sojka
Paul E. Sojka
Jun ChenJun Chen
Jun Chen
Quantitative application of digital in-line holography (DIH) to characterize multiphase fragmentation is demonstrated. DIH is applied to record sequential holograms of the breakup of an ethanol droplet in an aerodynamic flow field. Various stages of the breakup process are recorded, including deformation, bag growth, bag breakup, and rim breakup. A recently proposed hybrid method is applied to extract the three-dimensional (3D) location and size of secondary droplets as well as the 3D morphology of the rim. Particle matching between sequential frames is used to determine the velocity. Coincidence with the results obtained from phase Doppler anemometry measurement demonstrates the accuracy of measurement by DIH and the hybrid method.

1 September 2017 in International Journal of Multiphase Flow
Verified
Journal Article
Closed access
DGDaniel R. Guildenbecher
Daniel R. Guildenbecher
JGJian Gao
Jian Gao
JCJun Chen
Jun Chen
PSPaul E. Sojka
Paul E. Sojka

7 August 2014 in Applied Optics
Verified
Journal Article
Closed access
PDF file
JGJian Gao
Jian Gao
DGDaniel R. Guildenbecher
Daniel R. Guildenbecher
LELuke Engvall
Luke Engvall
PRPhillip L. Reu
Phillip L. Reu
Jun ChenJun Chen
Jun Chen
Digital in-line holography provides simultaneous particle size and three-dimensional position measurements. In general, the measurement accuracy varies locally, and tends to decrease where particles are closely spaced, due to noise resulting from diffraction by adjacent particles. Aggravating the situation is the identification of transversely adjoining particles as a single particle, which introduces significant errors in both size and position measurements. Here, we develop a refinement procedure that distinguishes such erroneous particles from accurately detected ones and further separates individual particles. Effectiveness of the refinement is characterized using simulations, experimental holograms of calibration fields, and a few practical applications to liquid breakup. Significant improvements in the accuracy of the measured particle sizes, positions, and displacements confirm the usefulness of the proposed method.

15 March 2014 in Experiments in Fluids
Verified
Journal Article
Closed access
PDF file
DGDaniel R. Guildenbecher
Daniel R. Guildenbecher
LELuke Engvall
Luke Engvall
JGJian Gao
Jian Gao
TGThomas W. Grasser
Thomas W. Grasser
PRPhillip L. Reu
Phillip L. Reu
JCJun Chen
Jun Chen