Hydroponic culture systems are subject to high risks of diseases caused by zoosporic plant pathogens. Control is generally difficult because of the rapid spread of zoospores in the nutrient solutions. In Japan, tomato and eustoma, which are cultivated using the D-tray and nutrient film techniques, respectively, are susceptible to diseases caused by Pythium aphanidermatum and P. irregulare. We used loop-mediated isothermal amplification to identify potential contamination sources of these two pathogens by monitoring their presence in the water supply wells, seedling terraces, nutrient solutions, diseased plants, and ground soils of a tomato greenhouse complex and a eustoma greenhouse complex. The results indicated that the pathogens may enter the culture systems from the soils around the greenhouses. Entry most likely occurs when seedlings are moved from the seedling terraces to the greenhouses, and sterilization of the hydroponic systems may not be sufficient. Therefore, monitoring pathogens in the culture systems and ground soils is very important for the management and prevention of these diseases.
The quartz crystal microbalance (QCM) technique based on graphitic carbon nitride (g-C3N4) modified QCM electrodes has been successfully used to detect H2 gas without the need for noble metal composite materials, and heating for operation.
Thin films of tantalum disulfide in the 1T-polytype structural phase (1T-TaS2), a type of metallic two-dimensional (2D) transition metal dichalcogenides (TMDs), are reactive to H2. Interestingly, in the incommensurate charge-density wave (ICCDW) phase with a metallic state, the electrical resistance of the 1T-TaS2 thin film decreases when H2 is adsorbed on it and returns to its initial value upon desorption. In contrast, the electrical resistance of the film in the nearly commensurate CDW (NCCDW) phase, which has a subtle band overlap or a small bandgap, does not change upon H2 adsorption/desorption. This difference in H2 reactivity is a result of differences in the electronic structure of the two 1T-TaS2 phases, namely, the ICCDW and NCCDW phases. Compared to other semiconductor 2D-TMDs such as MoS2 and WS2, the metallic TaS2 has been theoretically proven to capture gas molecules more easily because Ta has a stronger positive charge than Mo or W. Our experimental results provide evidence of this. Notably, this study is the first example of H2 sensing using 1T-TaS2 thin films and demonstrates the possibility of controlling the reactivity of the sensors to the gas by changing the electronic structure via CDW phase transitions.
A graphitic carbon nitride (g-C3N4) with nitrogen-vacancy defects was synthesized by calcination of a mixture of melamine and potassium hydroxide (KOH). The nitrogen/carbon ratio (N/C) of the g-C3N4 film decreased with the addition of KOH, indicating that the KOH addition could control the nitrogen-vacancy defects in the g-C3N4. The g-C3N4 films with nitrogen-vacancy defects were formed on a quartz crystal substrate. The change in the resonant frequency of the crystal was measured before and after the introduction of hydrogen gas, utilizing the quartz crystal microbalance (QCM) method. This approach was employed to characterize the hydrogen sensor effectively. The QCM-type sensor with the defective g-C3N4 film had a different frequency response to the hydrogen than the sensor with pristine g-C3N4 film synthesized without KOH addition. That is, the resonant frequency of the defective g-C3N4 decreased with the introduction of hydrogen, while that of pristine g-C3N4 was observed to increase. The reduced frequency of the defective g-C3N4 is probably due to the formation of chemical bonds with hydrogen (C-H) as observed in the FT-IR measurements. Our findings show that the introduction of nitrogen-vacancy defects into the g-C3N4 significantly impacts the characteristics of QCM-type hydrogen sensors. Moreover, controlling the amount of nitrogen vacancies introduced has a significant effect on the frequency response to the hydrogen gas. The QCM-type sensor utilizing g-C3N4 is anticipated to find applications in a range of gas sensors in the future, contingent upon the progress of research focused on controlling the precise number of nitrogen-vacancy defects.