Hugh C. Davis

Hugh C. Davis

Auto-generated profile, based on publicly available information

Hugh C. Davis

University of Florida – Shands Hospital

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 September 2025 in Journal of the American Heart Association
Verified
Journal Article
Open access
JMJohn M. Moriarty
John M. Moriarty
BSBrian J. Schiro
Brian J. Schiro
SDSuhail Dohad
Suhail Dohad
HTHouman Tamaddon
Houman Tamaddon
HDHugh C. Davis
Hugh C. Davis
IWIdo Weinberg
Ido Weinberg
Background: Pulmonary embolism (PE) can be a life‐threatening condition. Endovascular treatment is emerging as a promising treatment to restore hemodynamic stability and reverse right ventricular (RV) dysfunction in PE; however, more studies are needed to elucidate the effects on the right ventricle after endovascular treatment. This analysis reports the effects of computer assisted vacuum thrombectomy on RV function. Methods: Eligible patients for the single‐arm, prospective, international, multicenter STRIKE‐PE (A Prospective, Multicenter Study of the Indigo Aspiration System Seeking to Evaluate the Long‐Term Safety and Outcomes of Treating Pulmonary Embolism) cohort study are adults with acute PE with symptoms for ≤14 days and an RV/left ventricular ratio of ≥0.9 who are treated with computer assisted vacuum thrombectomy. Reported here are periprocedural and RV outcomes of the initial 300 patients of STRIKE‐PE, to provide insights into effects on RV function after computer assisted vacuum thrombectomy. Results: Patients were classified with high‐risk (5.7%), intermediate‐high‐risk (84.7%), or intermediate‐low‐risk (9.7%) PE. Median thrombectomy time was 30 minutes. Mean on‐table systolic pulmonary artery pressure decreased from 51.7 mm Hg to 41.3 mm Hg, a 19.1% reduction ( P <0.001). The change in mean RV/left ventricular ratio from baseline to 48 hours postprocedure (primary effectiveness end point) was a decrease from 1.40 to 0.99, a 26.8% reduction ( P <0.001). Clinical parameters and echocardiographic measures of right heart strain improved from baseline to 48 hours postprocedure ( P <0.001). The rate of composite major adverse events within 48 hours postprocedure (primary safety end point) was 2.0%. Median Borg dyspnea scale at rest decreased from 4.0 at baseline to 0.5 at discharge ( P <0.001). Conclusions: This interim analysis demonstrates that computer assisted vacuum thrombectomy safely and expeditiously improves hemodynamic status, RV function, and perceived dyspnea. Registration: URL: https://clinicaltrials.gov ; Unique Identifier: NCT04798261.

1 September 2023 in Diagnostic and Interventional Radiology
Verified
Journal Article
Open access
TTTyler S. Thompson
Tyler S. Thompson
CSCoulter N. Small
Coulter N. Small
HDHugh Davis
Hugh Davis
MLMichael Lazarowicz
Michael Lazarowicz
JVJeffrey Vogel
Jeffrey Vogel
RHRobert E. Heithaus
Robert E. Heithaus
The purpose of this study was to determine whether retention of a post-pyloric Dobhoff tube (DHT) in position to serve as a visual guide through the pylorus during gastrojejunostomy (GJ) tube placement results in a reduction in fluoroscopy time, procedure time, and estimated radiation dose. A retrospective study evaluated patients who underwent GJ tube placement or gastric to GJ conversion from January 1, 2017, to April 1, 2021. Demographic and procedural data were collected, and results were evaluated using descriptive statistics and hypothesis testing through an unpaired Student's t-test. Of the 71 GJ tube placements included for analysis, 12 patients underwent placement with a post-pyloric DHT in position, and 59 patients underwent placement without a post-pyloric DHT in position. The mean fluoroscopy time and estimated radiation dose were significantly reduced in patients who underwent GJ tube placement with a post-pyloric DHT in position compared with those without (7.08 min vs. 11.02 min, P = 0.004; 123.12 mGy vs. 255.19 mGy, P = 0.015, respectively). The mean total procedure time was also reduced in patients who underwent GJ tube placement with a post-pyloric DHT in position compared with those who had no post-pyloric DHT, but this finding lacked statistical significance (18.55 min vs. 23.15 min; P = 0.09). Post-pyloric DHT retention can be utilized during GJ tube placement to reduce radiation exposure to both the patient and interventionalist.