Alice Self

Alice Self

Auto-generated profile, based on publicly available information

Alice Self

Nuffield Department of Women’s and Reproductive Health, University of Oxford, Oxford, UK

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2020 in Journal of Medical Imaging
Verified
Journal Article
Closed access
PDF file
MMMohammed A. Maraci
Mohammed A. Maraci
MYMohammad Yaqub
Mohammad Yaqub
RCRachel Craik
Rachel Craik
SBSridevi Beriwal
Sridevi Beriwal
ASAlice Self
Alice Self
JNJ. Alison Noble
J. Alison Noble
<!-- *** Custom HTML *** --> Obstetric ultrasound is a fundamental ingredient of modern prenatal care with many applications including accurate dating of a pregnancy, identifying pregnancy-related complications, and diagnosis of fetal abnormalities. However, despite its many benefits, two factors currently prevent wide-scale uptake of this technology for point-of-care clinical decision-making in low- and middle-income country (LMIC) settings. First, there is a steep learning curve for scan proficiency, and second, there has been a lack of easy-to-use, affordable, and portable ultrasound devices. We introduce a framework toward addressing these barriers, enabled by recent advances in machine learning applied to medical imaging. The framework is designed to be realizable as a point-of-care ultrasound (POCUS) solution with an affordable wireless ultrasound probe, a smartphone or tablet, and automated machine-learning-based image processing. Specifically, we propose a machine-learning-based algorithm pipeline designed to automatically estimate the gestational age of a fetus from a short fetal ultrasound scan. We present proof-of-concept evaluation of accuracy of the key image analysis algorithms for automatic head transcerebellar plane detection, automatic transcerebellar diameter measurement, and estimation of gestational age on conventional ultrasound data simulating the POCUS task and discuss next steps toward translation via a first application on clinical ultrasound video from a low-cost ultrasound probe.

1 September 2022 in JMIR Research Protocols
Verified
Journal Article
Open access
ASAlice Self
Alice Self
QCQingchao Chen
Qingchao Chen
BDBapu Koundinya Desiraju
Bapu Koundinya Desiraju
SDSumeet Dhariwal
Sumeet Dhariwal
AGAlexander D Gleed
Alexander D Gleed
JNJ Alison Noble
J Alison Noble
Background: The World Health Organization recommends a package of pregnancy care that includes obstetric ultrasound scans. There are significant barriers to universal access to antenatal ultrasound, particularly because of the cost and need for maintenance of ultrasound equipment and a lack of trained personnel. As low-cost, handheld ultrasound devices have become widely available, the current roadblock is the global shortage of health care providers trained in obstetric scanning. Objective: The aim of this study is to improve pregnancy and risk assessment for women in underserved regions. Therefore, we are undertaking the Computer-Assisted Low-Cost Point-of-Care UltraSound (CALOPUS) project, bringing together experts in machine learning and clinical obstetric ultrasound. Methods: In this prospective study conducted in two clinical centers (United Kingdom and India), participating pregnant women were scanned and full-length ultrasounds were performed. Each woman underwent 2 consecutive ultrasound scans. The first was a series of simple, standardized ultrasound sweeps (the CALOPUS protocol), immediately followed by a routine, full clinical ultrasound examination that served as the comparator. We describe the development of a simple-to-use clinical protocol designed for nonexpert users to assess fetal viability, detect the presence of multiple pregnancies, evaluate placental location, assess amniotic fluid volume, determine fetal presentation, and perform basic fetal biometry. The CALOPUS protocol was designed using the smallest number of steps to minimize redundant information, while maximizing diagnostic information. Here, we describe how ultrasound videos and annotations are captured for machine learning. Results: Over 5571 scans have been acquired, from which 1,541,751 label annotations have been performed. An adapted protocol, including a low pelvic brim sweep and a well-filled maternal bladder, improved visualization of the cervix from 28% to 91% and classification of placental location from 82% to 94%. Excellent levels of intra- and interannotator agreement are achievable following training and standardization. Conclusions: The CALOPUS study is a unique study that uses obstetric ultrasound videos and annotations from pregnancies dated from 11 weeks and followed up until birth using novel ultrasound and annotation protocols. The data from this study are being used to develop and test several different machine learning algorithms to address key clinical diagnostic questions pertaining to obstetric risk management. We also highlight some of the challenges and potential solutions to interdisciplinary multinational imaging collaboration. International Registered Report Identifier (IRRID): RR1-10.2196/37374

1 September 2022 in Ultrasound in Obstetrics & Gynecology
Verified
Journal Article
Open access
RAR. X. Allwood
R. X. Allwood
ASA. Self
A. Self
SCS. L. Collins
S. L. Collins
Objective: To assess the performance of the ‘separation sign’ as a predictor of normal placental separation in a large cohort of women at risk for placenta accreta spectrum (PAS) and in a high‐risk subgroup with placenta previa or anterior low‐lying placenta and at least one previous Cesarean delivery.Methods: This was a prospective study of women at risk for PAS referred to a specialist clinic at between 22 and 38 weeks' gestation. All women underwent ultrasound assessment for the presence of the separation sign, which detects the difference in elasticity between the myometrium and the placenta, characterized by different rates of rebound after an ultrasound probe is used to apply pressure over the uteroplacental interface. When the sign is positive, the placenta appears to move relative to the myometrium, leading to the appearance or enhancement of the clear zone. The predictive performance of the separation sign for normal spontaneous placental separation at delivery was assessed.Results: Of the 194 included women, 163 had a positive separation sign, all of whom went on to have normal placental separation at delivery. Of the 24 women with a negative separation sign, three (12.5%) had normal placental separation and 21 (87.5%) were diagnosed with PAS. This yielded a sensitivity of 98.2% (95% CI, 94.8–99.6%) and specificity of 100% (95% CI, 83.9–100%). In the high‐risk cohort (n = 35), a positive separation sign remained a reliable predictor of normal placental separation, with a positive predictive value of 100%, sensitivity of 88.9% (95% CI, 65.3–98.6%) and specificity of 100% (95% CI, 80.5–100%).Conclusions: The separation sign could be a useful tool in women considered to be at risk for PAS, as it can facilitate the prediction of normal placental separation at delivery. This may prevent overtreatment, the associated iatrogenic morbidity and unnecessary allocation of clinical resources. © 2022 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.

8 August 2024 in BJOG: An International Journal of Obstetrics & Gynaecology
Verified
Journal Article
Open access
ASAlice Self
Alice Self
MSMichael Schlussel
Michael Schlussel
GCGary S. Collins
Gary S. Collins
FDFerdinand Dhombres
Ferdinand Dhombres
NFNicolas Fries
Nicolas Fries
APAris T. Papageorghiou
Aris T. Papageorghiou
Objectives: Accurate assessment of gestational age (GA) is important at both individual and population levels. The most accurate way to estimate GA in women who book late in pregnancy is unknown. The aim of this study was to externally validate the accuracy of equations for GA estimation in late pregnancy and to identify the best equation for estimating GA in women who do not receive an ultrasound scan until the second or third trimester. Design: This was a prospective, observational cross‐sectional study. Setting: 57 prenatal care centres, France. Participants: Women with a singleton pregnancy and a previous 11–14‐week dating scan that gave the observed GA were recruited over an 8‐week period. They underwent a standardised ultrasound examination at one time point during the pregnancy (15–43 weeks), measuring 12 foetal biometric parameters that have previously been identified as useful for GA estimation. Main Outcome Measures: A total of 189 equations that estimate GA based on foetal biometry were examined and compared with GA estimation based on foetal CRL. Comparisons between the observed GA and the estimated GA were made using R 2 , calibration slope and intercept. RMSE, mean difference and 95% range of error were also calculated. Results: A total of 2741 pregnant women were examined. After exclusions, 2339 participants were included. In the 20 best performing equations, the intercept ranged from −0.22 to 0.30, the calibration slope from 0.96 to 1.03 and the RSME from 0.67 to 0.87. Overall, multiparameter models outperformed single‐parameter models. Both the 95% range of error and mean difference increased with gestation. Commonly used models based on measurement of the head circumference alone were not amongst the best performing models and were associated with higher 95% error and mean difference. Conclusions: We provide strong evidence that GA‐specific equations based on multiparameter models should be used to estimate GA in late pregnancy. However, as all methods of GA assessment in late pregnancy are associated with large prediction intervals, efforts to improve access to early antenatal ultrasound must remain a priority. Trial Registration: The proposal for this study and the corresponding methodological review was registered on PROSPERO international register of systematic reviews (registration number: CRD4201913776).


19 October 2026 in BMC Pregnancy and Childbirth
Verified
Journal Article
Open access
PDF file
AGAlexander D. Gleed
Alexander D. Gleed
MGMudita Gosain
Mudita Gosain
RTRamachandran Thiruvengadam
Ramachandran Thiruvengadam
SRSaranya Rajaram
Saranya Rajaram
NRNiranjan Rajasekar
Niranjan Rajasekar
JNJ. Alison Noble
J. Alison Noble
Background: In this study, we use quantitative and qualitative assessments to evaluate the feasibility and usability of an obstetric ultrasound video colour overlay to assist placenta localisation and hence risk stratify high-risk pregnancies that have a low-lying placenta. The colour overlay (designed in a previous study) simplifies clinical interpretation of ultrasound video to support screening for pregnant women in rural and low- and middle-income country (LMIC) settings who do not receive care, partly because of a trained operator shortage. Methods: For feasibility, we assessed risk stratification (or checking for a low-lying placenta) of a trained sonographer (6.5 years of experience) using the combined video and colour overlay compared with a hospital freehand scan without a colour overlay. For usability, we recruited 31 Indian healthcare system clinicians in both north and south India hospital sites. We assessed clinical opinions and perceptions of the colour overlay over four study rounds of written questionnaires and a single round of oral interviews. In each round, participants interacted with 20 colour overlays on a portable tablet computer. Results: For feasibility, the sonographer successfully risk stratified the 2 low-lying, high-risk placentas out of a cohort of 55 unique pregnancies (1 video per pregnancy). However, this approach also resulted in 18 false positives (normal placentas that were incorrectly labelled as low-lying). Future feasibility assessment would need to use a larger cohort of pregnancies to strengthen the preliminary findings reported here. For usability, participants gave positive written responses and reported an increase in both confidence when using the colour overlay, and trust in the colour overlay post-study compared to pre-study. From qualitative coding of interview transcripts (1,643 codes and 13 themes generated), the colour overlay was overwhelmingly perceived as an effective risk stratification tool and usable by healthcare workers in rural and LMIC settings. Non-trivial perceived challenges to translation included compliance of the colour overlay with India’s current fetal sex determination law (Pre-Conception and Pre-Natal Diagnostic Techniques Act, 1994), including compliance of targeted users of rural healthcare workers (who cannot currently legally use ultrasound devices), and ultrasound device purchase and maintenance costs. Conclusions: Overall, the colour overlay was perceived favourably by clinicians. For successful adoption of the technology in the Indian healthcare system, the non-technical issues raised would need to be carefully and sensitively addressed.