Jon O. Cleary

Jon O. Cleary

Auto-generated profile, based on publicly available information

Jon O. Cleary

Department of Radiology, Guy’s and St. Thomas’ NHS Foundation Trust, London, UK

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2009 in The Lancet
Verified
Journal Article
Closed access
STSudhin Thayyil
Sudhin Thayyil
JCJon O Cleary
Jon O Cleary
NSNeil J Sebire
Neil J Sebire
RSRosemary J Scott
Rosemary J Scott
KCKling Chong
Kling Chong
ATAndrew M Taylor
Andrew M Taylor

1 January 2012 in Journal of Biomedical Optics
Verified
Journal Article
Closed access
PDF file
JLJan Laufer
Jan Laufer
FNFrancesca Norris
Francesca Norris
JCJon Cleary
Jon Cleary
EZEdward Zhang
Edward Zhang
BTBradley Treeby
Bradley Treeby
PBPaul Beard
Paul Beard
The ability to noninvasively image embryonic vascular anatomy in mouse models is an important requirement for characterizing the development of the normal cardiovascular system and malformations in the heart and vascular supply. Photoacoustic imaging, which can provide high resolution non invasive images of the vasculature based upon optical absorption by endogenous hemoglobin, is well suited to this application. In this study, photoacoustic images of mouse embryos were obtained ex vivo and in vivo. The images show intricate details of the embryonic vascular system to depths of up to 10 mm, which allowed whole embryos to be imaged in situ. To achieve this, an all-optical photoacoustic scanner and a novel time reversal image reconstruction algorithm, which provide deep tissue imaging capability while maintaining high spatial resolution and contrast were employed. This technology may find application as an imaging tool for preclinical embryo studies in developmental biology as well as more generally in preclinical and clinical medicine for studying pathologies characterized by changes in the vasculature.

1 January 2011 in NeuroImage
Verified
Journal Article
Closed access
JCJon O. Cleary
Jon O. Cleary
MMMarc Modat
Marc Modat
FNFrancesca C. Norris
Francesca C. Norris
APAnthony N. Price
Anthony N. Price
SJSujatha A. Jayakody
Sujatha A. Jayakody
MLMark F. Lythgoe
Mark F. Lythgoe

1 June 2011 in NeuroImage
Verified
Journal Article
Open access
JCJon O. Cleary
Jon O. Cleary
FWFrances K. Wiseman
Frances K. Wiseman
FNFrancesca C. Norris
Francesca C. Norris
APAnthony N. Price
Anthony N. Price
MCManKin Choy
ManKin Choy
MLMark F. Lythgoe
Mark F. Lythgoe
Extensive worldwide efforts are underway to produce knockout mice for each of the ~25,000 mouse genes, which may give new insights into the underlying pathophysiology of neurological disease. Microscopic magnetic resonance imaging (μMRI) is a key method for non-invasive morphological phenotyping, capable of producing high-resolution 3D images of ex-vivo brains, after fixation with an MR contrast agent. These agents have been suggested to act as active-stains, enhancing structures not normally visible on MRI. In this study, we investigated the structural correlates of the MRI agent Gd-DTPA, together with the optimal preparation and scan parameters for contrast-enhanced gradient-echo imaging of the mouse brain. We observed that in-situ preparation was preferential to ex-situ due to the degree of extraction damage. In-situ brains scanned with optimised parameters, enabled images with a high signal-to-noise-ratio (SNR ~30) and comprehensive anatomical delineation. Direct correlation of the MR brain structures to histology, detailed fine histoarchitecture in the cortex, cerebellum, olfactory bulb and hippocampus. Neurofilament staining demonstrated that regions of negative MR contrast strongly correlated to myelinated white-matter structures, whilst structures of more positive MR contrast corresponded to areas with high grey matter content. We were able to identify many sub-regions, particularly within the hippocampus, such as the unmyelinated mossy fibres (stratum lucidum) and their region of synapse in the stratum pyramidale, together with the granular layer of the dentate gyrus, an area of densely packed cell bodies, which was clearly visible as a region of hyperintensity. This suggests that cellular structure influences the site-specific distribution of the MR contrast agent, resulting in local variations in T(2)*, which leads to enhanced tissue discrimination. Our findings provide insights not only into the cellular distribution and mechanism of MR active-staining, but also allow for three dimensional analysis, which enables interpretation of magnetic resonance microscopy brain data and highlights cellular structure for investigation of disease processes in development and disease.

29 September 2010 in Journal of Magnetic Resonance Imaging
Verified
Journal Article
Open access
PDF file
JRJohannes Riegler
Johannes Riegler
KCKing K. Cheung
King K. Cheung
YMYiu Fung Man
Yiu Fung Man
JCJon O. Cleary
Jon O. Cleary
APAnthony N. Price
Anthony N. Price
MLMark F. Lythgoe
Mark F. Lythgoe
Purpose To establish the accuracy, intra- and inter-observer variabilities of four different segmentation methods for measuring cardiac functional parameters in healthy and infarcted rat hearts. Materials and Methods Six Wistar rats were imaged before and after myocardial infarction using an electrocardiogram and respiratory-gated spoiled gradient echo sequence. Blinded and randomized datasets were analyzed by various semi-automatic and manual segmentation methods to compare their measurement bias and variability. In addition, the accuracy of these methods was assessed by comparison with reference measurements acquired from high-resolution three-dimensional (3D) datasets of a heart phantom. Results Relative inter- and intra-observer variability were found to be similar for all four methods. Semi-automatic segmentation methods reduced analysis time by up to 70%, while yielding similar measurement bias and variability compared with manual segmentation. Semi-automatic methods were found to underestimate the ejection fraction for healthy hearts compared with manual segmentation while overestimating them in infarcted hearts. However, semi-automatic segmentation of short axis slices agreed better with 3D reference scans of a heart phantom compared with manual segmentation. Conclusion Semi-automatic segmentation methods are faster than manual segmentation, while offering a similar intra- and inter-observer variability. However, a potential bias has been observed between healthy and infarcted hearts for different methods, which should also be considered when selecting the most appropriate analysis technique. J. Magn. Reson. Imaging 2010;32:869–877.

26 November 2010 in The Open Cardiovascular Medicine Journal
Verified
Journal Article
Open access
APAnthony N. Price
Anthony N. Price
KCKing K. Cheung
King K. Cheung
JCJon O Cleary
Jon O Cleary
ACAdrienne E Campbell
Adrienne E Campbell
JRJohannes Riegler
Johannes Riegler
MLMark F Lythgoe
Mark F Lythgoe
Cardiovascular magnetic resonance (CMR) imaging is the modality of choice for clinical studies of the heart and vasculature, offering detailed images of both structure and function with high temporal resolution. Small animals are increasingly used for genetic and translational research, in conjunction with models of common pathologies such as myocardial infarction. In all cases, effective methods for characterising a wide range of functional and anatomical parameters are crucial for robust studies. CMR is the gold-standard for the non-invasive examination of these models, although physiological differences, such as rapid heart rate, make this a greater challenge than conventional clinical imaging. However, with the help of specialised magnetic resonance (MR) systems, novel gating strategies and optimised pulse sequences, high-quality images can be obtained in these animals despite their small size. In this review, we provide an overview of the principal CMR techniques for small animals for example cine, angiography and perfusion imaging, which can provide measures such as ejection fraction, vessel anatomy and local blood flow, respectively. In combination with MR contrast agents, regional dysfunction in the heart can also be identified and assessed. We also discuss optimal methods for analysing CMR data, particularly the use of semi-automated tools for parameter measurement to reduce analysis time. Finally, we describe current and emerging methods for imaging the developing heart, aiding characterisation of congenital cardiovascular defects. Advanced small animal CMR now offers an unparalleled range of cardiovascular assessments. Employing these methods should allow new insights into the structural, functional and molecular basis of the cardiovascular system.