Morgana de Souza Camargo

Morgana de Souza Camargo

Auto-generated profile, based on publicly available information

Morgana de Souza Camargo

Grupo de Química Ambiental, Departamento de Química, Universidade Federal do Paraná, Curitiba, Brazil

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 February 2023 in Analytical Sciences
Verified
Journal Article
Closed access
PDF file
RDRafael Garrett Dolatto
Rafael Garrett Dolatto
GPGiorgi Dal Pont
Giorgi Dal Pont
HVHugo Sarmiento Vela
Hugo Sarmiento Vela
MCMorgana de Souza Camargo
Morgana de Souza Camargo
AOAntonio Ostrensky
Antonio Ostrensky
MGMarco Tadeu Grassi
Marco Tadeu Grassi

1 January 2026 in Journal of the Brazilian Chemical Society
Verified
Journal Article
Closed access
DDDébora A. Domingues
Débora A. Domingues
RDRafael Garrett Dolatto
Rafael Garrett Dolatto
FSFrederico Luis Felipe Soares
Frederico Luis Felipe Soares
MCMorgana S. Camargo
Morgana S. Camargo
LALincoln G. S. de Aquino
Lincoln G. S. de Aquino
MGMarco Tadeu Grassi
Marco Tadeu Grassi
A disposable pipette extraction method using ionic liquid-intercalated montmorillonite as sorbent was developed and optimized for the determination of low-molecular-weight polycyclic aromatic hydrocarbons in seawater by gas chromatography-mass spectrometry. Multivariate experimental designs were employed to optimize the extraction parameters, enabling a miniaturized procedure that required small amounts of sorbent, sample, and solvent. The optimized conditions included 15 mg of sorbent, 2.6 mL of sample, 13 extraction cycles, 10 desorption cycles, and 250 µL of hexane as desorption solvent. The method exhibited good linearity over the range 0.1-3.0 µg L-¹ (determination coefficient (R2) > 0.99), with limits of detection and quantification of 0.03 and 0.10 µg L-¹, respectively. Recovery values ranged from 71 to 123%, with deviations attributed to normal experimental variability rather than systematic bias. The optimized protocol provided efficient extraction using a simplified workflow and reduced reagent consumption, in agreement with green analytical chemistry principles. Application to a seawater sample confirmed the occurrence of polycyclic aromatic hydrocarbons and enabled reliable quantification at trace levels (ng-µg L-¹), demonstrating the suitability of the method for routine environmental monitoring.