20 May 2016 in RSC Advances
The absorber layer in a CdTe solar cell is made of a polycrystalline CdTe thin film with a thickness of several μm. It is highly desirable that the CdTe film could be made of through-thickness CdTe grains. In such a case, the photon-generated carriers could be transported to the positive and negative contacts without encountering any grain boundaries in CdTe, thus significantly reducing the carrier scattering/recombination occurring at the grain boundary. We propose and demonstrate that one of the most important roles for the presence of oxygen during the CdTe film growth is to in situ form a low-melting liquid mixture of oxides (CdTeOx, TeOx and CdOx), Te, and CdTe on the growth front of the CdTe grain surface. This liquid mixture, having a thickness of ∼50 nm, assists material transport from the vapor through the liquid to the liquid–solid interface, where Cd, Te, and Cd–Te molecules reacted to epitaxially deposit on the CdTe growth front. Assisted by a highly crystalline mono-grained CdS window layer template, CdTe preferential growth with through-thickness grains along the normal direction of the film has been achieved. CdTe solar cells fabricated with such CdTe absorbers demonstrate much enhanced external quantum efficiency, and cells with efficiencies as high as 14–15.2% have been fabricated.
6 November 2023 in Optics Express
In microscopic fringe projection profilometry (MFPP), the traditional absolute phase retrieval method using composite frequency fringe has the shortcomings of low accuracy and poor robustness due to mutual crosstalk of harmonic from the different channels of frequency-division multiplexing. In this study, an absolute phase retrieval method that avoids the inter-channel crosstalk is proposed. By introducing guard bands to accommodate the frequency channels corresponding to the second harmonic that dominate the high order harmonics, the aliasing between the second harmonic and the fundamental is eliminated. Consequently, phase maps without crosstalk can be demodulated using appropriate phase-shifting algorithms. The proposed method is well-suited for high-precision three-dimensional shape measurement scenarios in many fields such as integrated circuit manufacturing process control and micro-electro-mechanical system quality inspection. The experiment results demonstrate that the anti-crosstalk method is effective and can realize three-dimensional reconstruction for discontinuous planar surface and spherical surface.
24 December 2024 in Optics Express
In response to the growing need for detecting subsurface defects at the hundred-nanometer scale, this study introduces what we believe to be a novel dark field through-focus scanning optical microscopy (DF-TSOM) technique. Subsurface defect samples were prepared with a depth of 100 µm and diameters of 1 µm, 0.4 µm, 0.2 µm, and 0.1 µm for experiments. Results demonstrate that DF-TSOM successfully detects subsurface defects with diameters 0.1 µm, a feat unattainable with traditional TSOM, which failed to accurately detect subsurface defects with diameters 0.4 µm. DF-TSOM improves the contrast by approximately 10 times compared to traditional TSOM when the subsurface defect diameter is 1 µm. This study presents a promising new approach for the detection of subsurface defects in transparent materials, offering advantages such as high sensitivity, enhanced contrast, a simplified hardware setup, and the potential for online detection.
8 February 2024 in Optics Letters
Multi-view microscopic fringe projection systems, which use high-resolution telecentric lenses and the Scheimpflug condition, face challenges in coinciding focal planes accurately, resulting in inconsistent measurements between views. In this Letter, we developed a sharpness evaluation function based on the total power of the line-spread function, which was subsequently used to generate a full-field sharpness distribution map. Then we employed the correlation between the sharpness map and orientation of the focal plane to precisely coincide the focal planes. Experimental results validate the proposed method and demonstrate its improved consistency in 3D reconstruction.
14 August 2024 in Measurement