Vivek R. Sant

Vivek R. Sant

Auto-generated profile, based on publicly available information

Vivek R. Sant

Section of Endocrine Surgery, Department of Surgery, UT Southwestern Medical Center, Dallas

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 April 2024 in The Journal of Clinical Endocrinology & Metabolism
Verified
Journal Article
Closed access
PDF file
VSVivek R Sant
Vivek R Sant
ARAshwath Radhachandran
Ashwath Radhachandran
VIVedrana Ivezic
Vedrana Ivezic
DLDenise Lee
Denise Lee
MLMasha J Livhits
Masha J Livhits
WSWilliam Speier
William Speier
Context: Use of artificial intelligence (AI) to predict clinical outcomes in thyroid nodule diagnostics has grown exponentially over the past decade. The greatest challenge is in understanding the best model to apply to one's own patient population, and how to operationalize such a model in practice. Evidence Acquisition: A literature search of PubMed and IEEE Xplore was conducted for English-language publications between January 1, 2015 and January 1, 2023, studying diagnostic tests on suspected thyroid nodules that used AI. We excluded articles without prospective or external validation, nonprimary literature, duplicates, focused on nonnodular thyroid conditions, not using AI, and those incidentally using AI in support of an experimental diagnostic outside standard clinical practice. Quality was graded by Oxford level of evidence. Evidence Synthesis: A total of 61 studies were identified; all performed external validation, 16 studies were prospective, and 33 compared a model to physician prediction of ground truth. Statistical validation was reported in 50 papers. A diagnostic pipeline was abstracted, yielding 5 high-level outcomes: (1) nodule localization, (2) ultrasound (US) risk score, (3) molecular status, (4) malignancy, and (5) long-term prognosis. Seven prospective studies validated a single commercial AI; strengths included automating nodule feature assessment from US and assisting the physician in predicting malignancy risk, while weaknesses included automated margin prediction and interobserver variability. Conclusion: Models predominantly used US images to predict malignancy. Of 4 Food and Drug Administration–approved products, only S-Detect was extensively validated. Implementing an AI model locally requires data sanitization and revalidation to ensure appropriate clinical performance.

1 May 2025 in Thyroid®
Verified
Journal Article
Closed access
SAShreeram Athreya
Shreeram Athreya
AMAndrew Melehy
Andrew Melehy
SSSujit Silas Armstrong Suthahar
Sujit Silas Armstrong Suthahar
VIVedrana Ivezić
Vedrana Ivezić
ARAshwath Radhachandran
Ashwath Radhachandran
WSWilliam Speier
William Speier
Indeterminate cytology (Bethesda III and IV) represents 15–30% of biopsied thyroid nodules and require additional diagnostic testing. Molecular testing (MT) is a commonly used diagnostic tool that evaluatesmalignancy risk through next generation sequencing of fine needle aspiration (FNA) samples. While MT achieves high sensitivity (97–100%) in ruling out malignancy, its specificity and positive predictive value (PPV) remain relatively low. This study proposes a multimodal deep learning model that integrates ultrasound (US) imaging with MT to improve risk stratification by enhancing PPV while maintaining high sensitivity. Combining these modalities leverages complementary information from both molecular and imaging data, addressing limitations in current approaches and offering a robust framework for evaluating indeterminate nodules. We retrospectively analyzed 333 patients with indeterminate thyroid nodules (259 benign, 74 malignant) at UCLA Medical Center between 2016 and 2022. We evaluated four configurations: whole frame US images, 256 × 256 patches, 128 × 128 patches, and an ensemble model combining the first three configurations. The clinical baseline consisted of Bethesda cytology and MT results. Models were assessed using five fold cross validation stratified by surgical outcomes. The clinical baseline (Bethesda + MT) achieved an AUROC of 0.728 [0.68, 0.78] with sensitivity of 0.946 [0.88, 1.00], specificity of 0.664 [0.60, 0.73], and PPV of 0.448 [0.41, 0.48]. The proposed ensemble model demonstrated improved performance, achieving an AUROC of 0.831 [0.77, 0.89] with a sensitivity of 0.946 [0.88, 1.00], specificity of 0.703 [0.66, 0.75], and PPV of 0.477 [0.46, 0.50]. These improvements were statistically significant (p = 0.0008). Our multimodal model enhances MT performance by providing statistically significant improvements in PPV and specificity while maintaining high sensitivity. Our framework could be leveraged to reduce the number of benign thyroid resections in patients with indeterminate nodules. However, this study is limited by its single center dataset, lack of external validation, and the use of binarized MT outputs rather than granular malignancy risk probabilities. Future work should validate these findings across diverse populations and larger external datasets for more comprehensive risk stratification.

3 November 2023 in Surgery
Verified
Journal Article
Closed access
RRRajam Raghunathan
Rajam Raghunathan
XLXochitl R. Longstaff
Xochitl R. Longstaff
EHElena G. Hughes
Elena G. Hughes
SLShanpeng J. Li
Shanpeng J. Li
VSVivek R. Sant
Vivek R. Sant
MLMasha J. Livhits
Masha J. Livhits

17 December 2024 in JMIR Biomedical Engineering
Verified
Journal Article
Open access
SAShreeram Athreya
Shreeram Athreya
ARAshwath Radhachandran
Ashwath Radhachandran
VIVedrana Ivezić
Vedrana Ivezić
VSVivek R Sant
Vivek R Sant
CACorey W Arnold
Corey W Arnold
WSWilliam Speier
William Speier
Background: Numerous studies have explored image processing techniques aimed at enhancing ultrasound images to narrow the performance gap between low-quality portable devices and high-end ultrasound equipment. These investigations often use registered image pairs created by modifying the same image through methods like down sampling or adding noise, rather than using separate images from different machines. Additionally, they rely on organ-specific features, limiting the models’ generalizability across various imaging conditions and devices. The challenge remains to develop a universal framework capable of improving image quality across different devices and conditions, independent of registration or specific organ characteristics. Objective: This study aims to develop a robust framework that enhances the quality of ultrasound images, particularly those captured with compact, portable devices, which are often constrained by low quality due to hardware limitations. The framework is designed to effectively process nonregistered ultrasound image pairs, a common challenge in medical imaging, across various clinical settings and device types. By addressing these challenges, the research seeks to provide a more generalized and adaptable solution that can be widely applied across diverse medical scenarios, improving the accessibility and quality of diagnostic imaging. Methods: A retrospective analysis was conducted by using a cycle-consistent generative adversarial network (CycleGAN) framework enhanced with perceptual loss to improve the quality of ultrasound images, focusing on nonregistered image pairs from various organ systems. The perceptual loss was integrated to preserve anatomical integrity by comparing deep features extracted from pretrained neural networks. The model’s performance was evaluated against corresponding high-resolution images, ensuring that the enhanced outputs closely mimic those from high-end ultrasound devices. The model was trained and validated using a publicly available, diverse dataset to ensure robustness and generalizability across different imaging scenarios. Results: The advanced CycleGAN framework, enhanced with perceptual loss, significantly outperformed the previous state-of-the-art, stable CycleGAN, in multiple evaluation metrics. Specifically, our method achieved a structural similarity index of 0.2889 versus 0.2502 (P<.001), a peak signal-to-noise ratio of 15.8935 versus 14.9430 (P<.001), and a learned perceptual image patch similarity score of 0.4490 versus 0.5005 (P<.001). These results demonstrate the model’s superior ability to enhance image quality while preserving critical anatomical details, thereby improving diagnostic usefulness. Conclusions: This study presents a significant advancement in ultrasound imaging by leveraging a CycleGAN model enhanced with perceptual loss to bridge the quality gap between images from different devices. By processing nonregistered image pairs, the model not only enhances visual quality but also ensures the preservation of essential anatomical structures, crucial for accurate diagnosis. This approach holds the potential to democratize high-quality ultrasound imaging, making it accessible through low-cost portable devices, thereby improving health care outcomes, particularly in resource-limited settings. Future research will focus on further validation and optimization for clinical use.

18 October 2024 in Surgery
Verified
Journal Article
Closed access
RRRajam Raghunathan
Rajam Raghunathan
AJAnna Jacobs
Anna Jacobs
VSVivek R. Sant
Vivek R. Sant
LKLizabeth J. King
Lizabeth J. King
GRGary Rothberger
Gary Rothberger
ISInsoo Suh
Insoo Suh

12 January 2024 in Computers in Biology and Medicine
Verified
Journal Article
Closed access
ARAshwath Radhachandran
Ashwath Radhachandran
AKAdam Kinzel
Adam Kinzel
JCJoseph Chen
Joseph Chen
VSVivek Sant
Vivek Sant
MPMaitraya Patel
Maitraya Patel
WSWilliam Speier
William Speier