Xing Qu

Xing Qu

Auto-generated profile, based on publicly available information

Xing Qu

School of Electrical Engineering, University of South China, Hengyang, China

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 August 2023 in IEEE Access
Verified
Journal Article
Open access
JWJuan Wen
Juan Wen
SLSiyu Lin
Siyu Lin
XQXing Qu
Xing Qu
QXQiankang Xiao
Qiankang Xiao
Vulnerability assessment is one of the effective ways to prevent cascading failures of a distribution network (DN). Aiming to accurately identify the vulnerable parts of the DN, a comprehensive assessment method based on Technique for Order Preference by Similarity to Ideal Solution (TOPSIS) considering topological structure and operation status is proposed. Considering the radial topology of DN, the structural vulnerability indices based on complex network theory are extended, such as degree and network efficiency. According to the system power flow and the network topology, the state vulnerability indices are established, such as electrical betweenness and power flow transfer entropy. Combining the Analytic Hierarchy Process (AHP) and the entropy weight method to obtain the comprehensive weight to give weight to each vulnerability index. The weighted vulnerability indices are substituted into the TOPSIS method to calculate the comprehensive vulnerability of each node and line in the DN where the obtained results are corrected by the grey correlation degree. The system transmission efficiency index is established to describe the degree of system performance degradation of the DN under different attack strategies. The simulation results of IEEE 33-bus test case show that the proposed method can effectively identify vulnerable nodes and lines in the DN.

13 August 2018 in IEEE Transactions on Power Systems
Verified
Journal Article
Closed access
XQXing Qu
Xing Qu
XLXinran Li
Xinran Li
JSJunying Song
Junying Song
CHCong He
Cong He
Loads are indirectly connected to the HV buses of substations through the HV network of a distribution network. However, existing composite load models used in measurement-based load modeling studies are not able to reflect these load situations. This letter proposes an extended composite load model that is suitable for measurement-based load modeling. The proposed load model consists of the equivalent model of an HV network and a traditional composite load model, having an upgraded performance in wider ranges of voltage.

1 November 2015
Verified
Conference Paper
Closed access
FXFu-Qiang Xie
Fu-Qiang Xie
SGSong Gao
Song Gao
XQXing Qu
Xing Qu
YTYao-Geng Tang
Yao-Geng Tang
The input and output characteristic of thermocouple vacuum gauge exhibits high nonlinearity, which comes from the gauges' inherent physical peculiarities and causes big error in measurement results. There is a need to make compensation of the nonlinearity for accurate measurement. In this article, a least squares support vector machine (LS-SVM) model is developed to function as a compensator with which to accomplish this task. Particle swarm optimization (PSO) algorithm is introduced to search optimal parameters combination of the LS-SVM model. Based on the real sensor measurements obtained from a solar water heater plant, experiments were performed to investigate the compensation accuracy with developed LS-SVM compensator model and higher compensation accuracy results were obtained.