José Alberto Giacometti

José Alberto Giacometti

Auto-generated profile, based on publicly available information

José Alberto Giacometti

Sao Paulo State University

Research Focus & Metrics

Academic Career Length

49Years (1978-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2005 in Carbohydrate Polymers
Verified
Journal Article
Closed access
CNC.G.T. Neto
C.G.T. Neto
JGJ.A. Giacometti
J.A. Giacometti
AJA.E. Job
A.E. Job
FFF.C. Ferreira
F.C. Ferreira
JFJ.L.C. Fonseca
J.L.C. Fonseca
MPM.R. Pereira
M.R. Pereira

1 October 1992 in IEEE Transactions on Electrical Insulation
Verified
Journal Article
Closed access
JGJ.A. Giacometti
J.A. Giacometti
OOO.N. Oliveira
O.N. Oliveira
A review of the corona charging of polymers is presented. After providing a brief account of the corona discharge process and of its application for charging materials, the paper focuses on the evolution of corona triodes that allow the sample surface potential to be monitored during the charging process. Particular emphasis is given to the main contributions arising from research, basically on Teflon FEP and ferroelectric polymers, in which a constant-current corona triode was used. Such a triode system has become a powerful tool in the study of charge transport and ferroelectric properties of polymers, because keeping the charging current constant facilitates matching of the experimental results to a number of theoretical models.

1 June 1999 in Brazilian Journal of Physics
Verified
Journal Article
Open access
PDF file
JGJosé A. Giacometti
José A. Giacometti
SFSergei Fedosov
Sergei Fedosov
MCMauro M. Costa
Mauro M. Costa
This paper contains a brief overview on the recent developments of corona charging of polymers, with emphasis on the current corona triode. This latter method, which has been successfully applied to several types of polymer, is a legacy from Prof. Bernhard Gross' work in São Carlos, Brazil. Following a short introduction to corona charging, the experimental setups are described, especially with regard to the advantages in the constant current method. A few examples are given of the use of the constant current corona triode in the investigation of electrical properties of nonpolar and ferroeleectric polymers. The application of corona charging to pole nonlinear optic (NLO) polymers is discussed, including the perspectives for the constant current charging method for the NLO field.

1 March 2005 in Applied Spectroscopy
Verified
Journal Article
Closed access
CCC. J. L. Constantino
C. J. L. Constantino
AJA. E. Job
A. E. Job
RSR. D. Simões
R. D. Simões
JGJ. A. Giacometti
J. A. Giacometti
Valtencir ZucolottoValtencir Zucolotto
Valtencir Zucolotto
DCD. L. Chinaglia
D. L. Chinaglia
The phase transition from the non-polar α-phase to the polar β-phase of poly(vinylidene fluoride) (PVDF) has been investigated using micro-Raman spectroscopy, which is advantageous because it is a nondestructive technique. Films of α-PVDF were subjected to stretching under controlled rates at 80 °C, while the transition to β-PVDF was monitored by the decrease in the Raman band at 794 cm −1 characteristic of the α-phase, along with the concomitant increase in the 839 cm −1 band characteristic of the β-phase. The α→β transition in our PVDF samples could be achieved even for the sample stretched to twice (2×-stretched) the initial length and it did not depend on the stretching rate in the range between 2.0 and 7.0 mm/min. These conclusions were corroborated by differential scanning calorimetry (DSC) and X-ray diffraction experiments for PVDF samples processed under the same conditions as in the Raman scattering measurements. Poling with negative corona discharge was found to affect the α-PVDF morphology, improving the Raman bands related to this crystalline phase. This effect is minimized for films stretched to higher ratios. Significantly, corona-induced effects could not be observed with the other experimental techniques, i.e., X-ray diffraction and infrared spectroscopy.

1 May 1986 in Journal of Applied Physics
Verified
Journal Article
Closed access
PDF file
GFG. F. Leal Ferreira
G. F. Leal Ferreira
OOO. N. Oliveira
O. N. Oliveira
JGJ. A. Giacometti
J. A. Giacometti
A series of measurements carried out with the point-to-plane symmetry has shown that positive corona confirms the Townsend relation while for the negative corona this happens only at large point-to-plane distances (greater than 1.5 cm). In this case, the ratio of the prefactors in Townsend relation, for the same geometry, approaches the expected constant (the ratio of the mobilities) at larger distances, around 6 cm. For distances below 1.5 cm, the square root of the current is linear with the voltage, with an intercept of ∼1.4 kV. The results are interpreted as giving evidence of an electronic component at small distances, as suggested by Sigmond. The characteristics change to Townsend at higher distances when the electronic component becomes small as compared with the ionic one.

1 January 1993 in Journal of Non-Crystalline Solids
Verified
Journal Article
Closed access
Carlos Mauricio LepienskiCarlos Mauricio Lepienski
Carlos Mauricio Lepienski
JGJ.A. Giacometti
J.A. Giacometti
GFG.F. Leal Ferreira
G.F. Leal Ferreira
FFF.L. Freire
F.L. Freire
CAC.A. Achete
C.A. Achete