Michael V. Mirkin

Michael V. Mirkin

Auto-generated profile, based on publicly available information

Michael V. Mirkin

Department of Chemistry and Biochemistry, Queens College, Flushing, NY 11367, USA

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 June 2022 in Science Advances
Verified
Journal Article
Closed access
LHLili Han
Lili Han
POPengfei Ou
Pengfei Ou
WLWei Liu
Wei Liu
XWXiang Wang
Xiang Wang
HWHsiao-Tsu Wang
Hsiao-Tsu Wang
HXHuolin L. Xin
Huolin L. Xin
Anion exchange membrane fuel cells are limited by the slow kinetics of alkaline hydrogen oxidation reaction (HOR). Here, we establish HOR catalytic activities of single-atom and diatomic sites as a function of *H and *OH binding energies to screen the optimal active sites for the HOR. As a result, the Ru-Ni diatomic one is identified as the best active center. Guided by the theoretical finding, we subsequently synthesize a catalyst with Ru-Ni diatomic sites supported on N-doped porous carbon, which exhibits excellent catalytic activity, CO tolerance, and stability for alkaline HOR and is also superior to single-site counterparts. In situ scanning electrochemical microscopy study validates the HOR activity resulting from the Ru-Ni diatomic sites. Furthermore, in situ x-ray absorption spectroscopy and computational studies unveil a synergistic interaction between Ru and Ni to promote the molecular H 2 dissociation and strengthen OH adsorption at the diatomic sites, and thus enhance the kinetics of HOR.

21 May 2012 in Proceedings of the National Academy of Sciences
Verified
Journal Article
Closed access
PDF file
YWYixian Wang
Yixian Wang
JNJean-Marc Noël
Jean-Marc Noël
JVJeyavel Velmurugan
Jeyavel Velmurugan
WNWojciech Nogala
Wojciech Nogala
MMMichael V. Mirkin
Michael V. Mirkin
CAChristian Amatore
Christian Amatore
Reactive oxygen and nitrogen species (ROS and RNS) produced by macrophages are essential for protecting a human body against bacteria and viruses. Micrometer-sized electrodes coated with Pt black have previously been used for selective and sensitive detection of ROS and RNS in biological systems. To determine ROS and RNS inside macrophages, one needs smaller (i.e., nanometer-sized) sensors. In this article, the methodologies have been extended to the fabrication and characterization of Pt/Pt black nanoelectrodes. Electrodes with the metal surface flush with glass insulator, most suitable for quantitative voltammetric experiments, were fabricated by electrodeposition of Pt black inside an etched nanocavity under the atomic force microscope control. Despite a nanometer-scale radius, the true surface area of Pt electrodes was sufficiently large to yield stable and reproducible responses to ROS and RNS in vitro. The prepared nanoprobes were used to penetrate cells and detect ROS and RNS inside macrophages. Weak and very short leaks of ROS/RNS from the vacuoles into the cytoplasm were detected, which a macrophage is equipped to clean within a couple of seconds, while higher intensity oxidative bursts due to the emptying of vacuoles outside persist on the time scale of tens of seconds.

11 September 2017 in Journal of the American Chemical Society
Verified
Journal Article
Closed access
YLYun Li
Yun Li
KHKeke Hu
Keke Hu
YYYun Yu
Yun Yu
SRSusan A. Rotenberg
Susan A. Rotenberg
CAChristian Amatore
Christian Amatore
MMMichael V. Mirkin
Michael V. Mirkin

15 January 2008 in Proceedings of the National Academy of Sciences
Verified
Journal Article
Closed access
PSPeng Sun
Peng Sun
FLFrançois O. Laforge
François O. Laforge
TAThushara P. Abeyweera
Thushara P. Abeyweera
SRSusan A. Rotenberg
Susan A. Rotenberg
JCJames Carpino
James Carpino
MMMichael V. Mirkin
Michael V. Mirkin
There is a significant current interest in development of new techniques for direct characterization of the intracellular redox state and high-resolution imaging of living cells. We used nanometer-sized amperometric probes in combination with the scanning electrochemical microscope (SECM) to carry out spatially resolved electrochemical experiments in cultured human breast cells. With the tip radius ≈1,000 times smaller than that of a cell, an electrochemical probe can penetrate a cell and travel inside it without apparent damage to the membrane. The data demonstrate the possibility of measuring the rate of transmembrane charge transport and membrane potential and probing redox properties at the subcellular level. The same experimental setup was used for nanoscale electrochemical imaging of the cell surface.

21 October 2014 in Angewandte Chemie International Edition
Verified
Journal Article
Closed access
PDF file
TSTong Sun
Tong Sun
YYYun Yu
Yun Yu
BZBrian J. Zacher
Brian J. Zacher
MMMichael V. Mirkin
Michael V. Mirkin

17 July 2007 in Proceedings of the National Academy of Sciences
Verified
Journal Article
Closed access
FLFrançois O. Laforge
François O. Laforge
JCJames Carpino
James Carpino
SRSusan A. Rotenberg
Susan A. Rotenberg
MMMichael V. Mirkin
Michael V. Mirkin
The ability to manipulate ultrasmall volumes of liquids is essential in such diverse fields as cell biology, microfluidics, capillary chromatography, and nanolithography. In cell biology, it is often necessary to inject material of high molecular weight (e.g., DNA, proteins) into living cells because their membranes are impermeable to such molecules. All techniques currently used for microinjection are plagued by two common problems: the relatively large injector size and volume of injected fluid, and poor control of the amount of injected material. Here we demonstrate the possibility of electrochemical control of the fluid motion that allows one to sample and dispense attoliter-to-picoliter (10 −18 to 10 −12 liter) volumes of either aqueous or nonaqueous solutions. By changing the voltage applied across the liquid/liquid interface, one can produce a sufficient force to draw solution inside a nanopipette and then inject it into an immobilized biological cell. A high success rate was achieved in injections of fluorescent dyes into cultured human breast cells. The injection of femtoliter-range volumes can be monitored by video microscopy, and current/resistance-based approaches can be used to control injections from very small pipettes. Other potential applications of the electrochemical syringe include fluid dispensing in nanolithography and pumping in microfluidic systems.