Silvia Meroni

Silvia Meroni

Auto-generated profile, based on publicly available information

Silvia Meroni

Unità Operativa di Pediatria e Neonatologia, IRCCS Ospedale S. Raffaele, Milano, Italia

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 April 2018 in Acta Oncologica
Verified
Journal Article
Open access
ESEnrica Seravalli
Enrica Seravalli
MBMirjam Bosman
Mirjam Bosman
YLYasmin Lassen-Ramshad
Yasmin Lassen-Ramshad
AVAnne Vestergaard
Anne Vestergaard
FOFoppe Oldenburger
Foppe Oldenburger
GJGeert O. Janssens
Geert O. Janssens
Purpose: Conventional techniques (3D-CRT) for craniospinal irradiation (CSI) are still widely used. Modern techniques (IMRT, VMAT, TomoTherapy®, proton pencil beam scanning [PBS]) are applied in a limited number of centers. For a 14-year-old patient, we aimed to compare dose distributions of five CSI techniques applied across Europe and generated according to the participating institute protocols, therefore representing daily practice. Material and methods: A multicenter (n = 15) dosimetric analysis of five different techniques for CSI (3D-CRT, IMRT, VMAT, TomoTherapy®, PBS; 3 centers per technique) was performed using the same patient data, set of delineations and dose prescription (36.0/1.8 Gy). Different treatment plans were optimized based on the same planning target volume margin. All participating institutes returned their best treatment plan applicable in clinic. Results: The modern radiotherapy techniques investigated resulted in superior conformity/homogeneity-indices (CI/HI), particularly in the spinal part of the target (CI: 3D-CRT:0.3 vs. modern:0.6; HI: 3D-CRT:0.2 vs. modern:0.1), and demonstrated a decreased dose to the thyroid, heart, esophagus and pancreas. Dose reductions of >10.0 Gy were observed with PBS compared to modern photon techniques for parotid glands, thyroid and pancreas. Following this technique, a wide range in dosimetry among centers using the same technique was observed (e.g., thyroid mean dose: VMAT: 5.6–24.6 Gy; PBS: 0.3–10.1 Gy). Conclusions: The investigated modern radiotherapy techniques demonstrate superior dosimetric results compared to 3D-CRT. The lowest mean dose for organs at risk is obtained with proton therapy. However, for a large number of organs ranges in mean doses were wide and overlapping between techniques making it difficult to recommend one radiotherapy technique over another.

11 April 2019 in Medical Physics
Verified
Journal Article
Closed access
PDF file
FBFrancesca Bonfantini
Francesca Bonfantini
TGTommaso Giandini
Tommaso Giandini
SMSilvia Meroni
Silvia Meroni
ACAnna Cavallo
Anna Cavallo
CSClaudio Stucchi
Claudio Stucchi
EPEmanuele Pignoli
Emanuele Pignoli

25 April 2019 in Strahlentherapie und Onkologie
Verified
Journal Article
Closed access
PDF file
SMSilvia Meroni
Silvia Meroni
CCClaudia Cavatorta
Claudia Cavatorta
SBSalvina Barra
Salvina Barra
FCFrancesca Cavagnetto
Francesca Cavagnetto
GSGiovanni Scarzello
Giovanni Scarzello
LGLorenza Gandola
Lorenza Gandola

16 March 2016 in Tumori Journal
Verified
Journal Article
Closed access
MSMaria Carmen De Santis
Maria Carmen De Santis
FBFrancesca Bonfantini
Francesca Bonfantini
MDMichela Dispinzieri
Michela Dispinzieri
SMSilvia Meroni
Silvia Meroni
BDBarbara Diletto
Barbara Diletto
LLLaura Lozza
Laura Lozza
Purpose: To evaluate the dosimetric coverage of axillary levels I, II, and III obtained with standard whole breast irradiation in 1 to 2 positive sentinel lymph nodes (SLNs) patients not submitted to axillary lymph nodes dissection (ALND), and to compare the lymph nodes areas coverage obtained with 3D conformal radiation therapy, intensity-modulated radiotherapy (IMRT), and volumetric modulated arc therapy (VMAT). Methods: Patients with 1 to 2 positive SLNs undergoing breast-conserving therapy, without ALND, were included in the analysis. For each patient, 3 treatment plans were performed: a 3D conventional tangential plan, a static IMRT plan, and a volumetric IMRT, designed to encompass the entire breast parenchyma. The volumes of axillary levels I, II, and III receiving 90% and 95% (V90, V95) of the whole breast prescribed dose were evaluated. Dose-volume histograms were compared by means of the Friedman test. Results: Ten patients were enrolled. All defined breast volumes received >95% of the prescribed dose with the 3 techniques. Median V95 for axillary level I was 26.4% (range 4.7%-61.3%) for 3D plans, 8.6% (range 0.64%-19.1%) for static IMRT plans, and 2.6% (range 0.4%-4.7%) for volumetric IMRT plans (p<0.001). Median V95 for axillary level II was 5.4% (range 0%-14.6%), 1.9% (range 0%-15%), and 2.6% (range 0.4%-4.7%) for 3D, static IMRT, and volumetric IMRT, respectively (p<0.001). Conclusions: Results of our analysis showed that standard 3D tangential whole breast irradiation failed to deliver a therapeutic dose to axillary levels I and II. The coverage was even lower using static and volumetric IMRT techniques.

26 February 2021 in PLOS ONE
Verified
Journal Article
Open access
PDF file
CCClaudia Cavatorta
Claudia Cavatorta
SMSilvia Meroni
Silvia Meroni
EMEros Montin
Eros Montin
MOMaria Chiara Oprandi
Maria Chiara Oprandi
EPEmilia Pecori
Emilia Pecori
LGLorenza Gandola
Lorenza Gandola
Purpose: To study a robust and reproducible procedure to investigate a relation between focal brain radiotherapy (RT) low doses, neurocognitive impairment and late White Matter and Gray Matter alterations, as shown by Diffusion Tensor Imaging (DTI), in children. Methods and materials: Forty-five patients (23 males and 22 females, median age at RT 6.2 years, median age at evaluations 11.1 years) who had received focal RT for brain tumors were recruited for DTI exams and neurocognitive tests. Patients’ brains were parceled in 116 regions of interest (ROIs) using an available segmented atlas. After the development of an ad hoc, home-made, multimodal and highly deformable registration framework, we collected mean RT doses and DTI metrics values for each ROI. The pattern of association between cognitive scores or domains and dose or DTI values was assessed in each ROI through both considering and excluding ROIs with mean doses higher than 75% of the prescription. Subsequently, a preliminary threshold value of dose discriminating patients with and without neurocognitive impairment was selected for the most relevant associations. Results: The workflow allowed us to identify 10 ROIs where RT dose and DTI metrics were significantly associated with cognitive tests results (p<0.05). In 5/10 ROIs, RT dose and cognitive tests were associated with p<0.01 and preliminary RT threshold dose values, implying a possible cognitive or neuropsychological damage, were calculated. The analysis of domains showed that the most involved one was the “school-related activities”. Conclusion: This analysis, despite being conducted on a retrospective cohort of children, shows that the identification of critical brain structures and respective radiation dose thresholds is achievable by combining, with appropriate methodological tools, the large amount of data arising from different sources. This supported the design of a prospective study to gain stronger evidence.

24 February 2016 in Journal of Radiological Protection
Verified
Journal Article
Closed access
PDF file
CCClaudia Cavatorta
Claudia Cavatorta
MLManuela Lualdi
Manuela Lualdi
SMSilvia Meroni
Silvia Meroni
GPGiovanni Polita
Giovanni Polita
MBMauro Bolchi
Mauro Bolchi
EPEmanuele Pignoli
Emanuele Pignoli
The evaluation of incoherent artificial optical radiation (AOR) exposure in hospital environments is a complex task due to the variety of sources available. This study has been designed to provide a proposal for the precautionary assessment of the related risk. This survey suggested that, in our Institution, at least three kinds of AOR sources required specific investigations: ambient lighting, theatre operating lighting and ultraviolet radiation (UVR) sources. For each kind of evaluated sources a specific measurement approach was developed. All irradiance measurements were made using a commercial spectroradiometer. The obtained results were compared with the appropriate exposure limit values (ELVs) defined in the International Commission on Non-Ionizing Radiation Protection (ICNIRP) guidelines and adopted by the European Directive 2006/25/EC. The risk related to the evaluated AOR exposure was finally assessed according to our risk matrix. According to our results, the emission of ambient lighting in the actual exposure conditions was always in accordance with the ELVs and the related risk was classifiable as not relevant. The risk related to the exposure to theatre operating lighting resulted not negligible, especially when two or more sources were used with focal spots overlapping on reflective objects. UVR sources emission may represent a health hazard depending, in particular, on the set up of the device containing the source. In case of laminar flow cabinets and closed transilluminators, if the UVR source is well contained within an enclosure with interlock, it presents no risk of exposure. Otherwise, the emission arising from UVR lamps, open transilluminators or sources not provided with interlock, may represent a risk classifiable as high even in the actual working conditions. The personal protective equipment used by workers were also assessed and their suitability was discussed.