Fuminori Hyodo

Fuminori Hyodo

Auto-generated profile, based on publicly available information

Fuminori Hyodo

Department of Pharmacology, Graduate School of Medicine, Gifu University, Gifu, Japan

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 February 2021 in British Journal of Radiology
Verified
Journal Article
Closed access
YNYoshifumi Noda
Yoshifumi Noda
TKTetsuro Kaga
Tetsuro Kaga
NKNobuyuki Kawai
Nobuyuki Kawai
TMToshiharu Miyoshi
Toshiharu Miyoshi
HKHiroshi Kawada
Hiroshi Kawada
MMMasayuki Matsuo
Masayuki Matsuo
Objectives: To evaluate image quality and lesion detection capabilities of low-dose (LD) portal venous phase whole-body computed tomography (CT) using deep learning image reconstruction (DLIR). Methods: The study cohort of 59 consecutive patients (mean age, 67.2 years) who underwent whole-body LD CT and a prior standard-dose (SD) CT reconstructed with hybrid iterative reconstruction (SD-IR) within one year for surveillance of malignancy were assessed. The LD CT images were reconstructed with hybrid iterative reconstruction of 40% (LD-IR) and DLIR (LD-DLIR). The radiologists independently evaluated image quality (5-point scale) and lesion detection. Attenuation values in Hounsfield units (HU) of the liver, pancreas, spleen, abdominal aorta, and portal vein; the background noise and signal-to-noise ratio (SNR) of the liver, pancreas, and spleen were calculated. Qualitative and quantitative parameters were compared between the SD-IR, LD-IR, and LD-DLIR images. The CT dose-index volumes (CTDIvol) and dose-length product (DLP) were compared between SD and LD scans. Results: The image quality and lesion detection rate of the LD-DLIR was comparable to the SD-IR. The image quality was significantly better in SD-IR than in LD-IR (p < 0.017). The attenuation values of all anatomical structures were comparable between the SD-IR and LD-DLIR (p = 0.28–0.96). However, background noise was significantly lower in the LD-DLIR (p < 0.001) and resulted in improved SNRs (p < 0.001) compared to the SD-IR and LD-IR images. The mean CTDIvol and DLP were significantly lower in the LD (2.9 mGy and 216.2 mGy•cm) than in the SD (13.5 mGy and 1011.6 mGy•cm) (p < 0.0001). Conclusion: LD CT images reconstructed with DLIR enable radiation dose reduction of >75% while maintaining image quality and lesion detection rate and superior SNR in comparison to SD-IR. Advances in knowledge: Deep learning image reconstruction algorithm enables around 80% reduction in radiation dose while maintaining the image quality and lesion detection compared to standard-dose whole-body CT.

20 May 2022 in British Journal of Radiology
Verified
Journal Article
Closed access
YNYoshifumi Noda
Yoshifumi Noda
NKNobuyuki Kawai
Nobuyuki Kawai
TKTomotaka Kawamura
Tomotaka Kawamura
AKAkikazu Kobori
Akikazu Kobori
RMRena Miyase
Rena Miyase
MMMasayuki Matsuo
Masayuki Matsuo
Objective: To evaluate the feasibility of a simultaneous reduction of radiation and iodine doses in dual-energy thoraco-abdomino-pelvic CT reconstructed with deep learning image reconstruction (DLIR). Methods: Thoraco-abdomino-pelvic CT was prospectively performed in 111 participants; 52 participants underwent a standard-dose single-energy CT with a standard iodine dose (600 mgI/kg; SD group), while 59 underwent a low-dose dual-energy CT with a reduced iodine dose [300 mgI/kg; double low-dose (DLD) group]. CT data were reconstructed with a hybrid iterative reconstruction in the SD group and a high-strength level of DLIR at 40 keV in the DLD group. Two radiologists measured the CT numbers of the descending and abdominal aorta, portal vein, hepatic vein, inferior vena cava, liver, pancreas, spleen, and kidney, and background noise. Two other radiologists assessed diagnostic acceptability using a 5-point scale. The CT dose-index volume (CTDIvol), iodine weight, CT numbers of anatomical structures, background noise, and diagnostic acceptability were compared between the two groups using Mann–Whitney U test. Results: The median CTDIvol [10 mGy; interquartile range (IQR), 9–13 mGy vs 4 mGy; IQR, 4–5 mGy] and median iodine weight (35 g; IQR, 31–38 g vs 16 g; IQR, 14–18 g) were lower in the DLD group than in the SD group (p < 0.001 for each). The CT numbers of all anatomical structures and background noise were higher in the DLD group than in the SD group (p < 0.001 for all). The diagnostic image quality was obtained in 100% (52/52) of participants in the SD group and 95% (56/59) of participants in the DLD group. Conclusion: Virtual monochromatic images at 40 keV reconstructed with DLIR could achieve half doses of radiation and iodine while maintaining diagnostic image quality. Advances in knowledge: Virtual monochromatic images at 40 keV reconstructed with DLIR algorithm allowed to reduce the doses of radiation and iodine while maintaining diagnostic image quality.

11 May 2021 in Abdominal Radiology
Verified
Journal Article
Closed access
PDF file
YNYoshifumi Noda
Yoshifumi Noda
YIYukako Iritani
Yukako Iritani
NKNobuyuki Kawai
Nobuyuki Kawai
TMToshiharu Miyoshi
Toshiharu Miyoshi
TITakuma Ishihara
Takuma Ishihara
MMMasayuki Matsuo
Masayuki Matsuo

22 February 2021 in British Journal of Radiology
Verified
Journal Article
Closed access
YNYoshifumi Noda
Yoshifumi Noda
FNFumihiko Nakamura
Fumihiko Nakamura
NYNoriyuki Yasuda
Noriyuki Yasuda
TMToshiharu Miyoshi
Toshiharu Miyoshi
NKNobuyuki Kawai
Nobuyuki Kawai
MMMasayuki Matsuo
Masayuki Matsuo
Objectives: To assess the feasibility of whole-body dual-energy computed tomographic angiography (DECTA) at 40 keV with 50% reduced iodine dose protocol. Methods: Whole-body CTA was performed in 65 patients; 31 of these patients underwent 120 kVp single-energy computed tomographic angiography (SECTA) with standard iodine dose (600 mgI/kg) and 34 with 40 keV DECTA with 50% reduced iodine dose (300 mgI/kg). SECTA data were reconstructed with adaptive statistical iterative reconstruction of 40% (SECTA group), and DECTA data were reconstructed with adaptive statistical iterative reconstruction of 40% (DECTA-40% group) and 80% (DECTA-80% group). CT numbers of the thoracic and abdominal aorta, iliac artery, background noise, signal-to-noise ratio (SNR), and arterial depiction were compared among the three groups. The CT dose index volumes (CTDIvol) for the thorax, abdomen, and pelvis were compared between SECTA and DECTA protocols. Results: The vascular CT numbers and background noise were found to be significantly higher in DECTA groups than in the SECTA group (p < 0.001). SNR was significantly higher in the order corresponding to DECTA-80%, SECTA, and DECTA-40% (p < 0.001). The arterial depiction was comparable in almost all arteries; however, intrapelvic arterial depiction was significantly worse in DECTA groups than in the SECTA group (p < 0.0001–0.017). Unlike the pelvic region (p = 0.055), CTDIvol for the thorax (p < 0.0001) and abdomen (p = 0.0031) were significantly higher in the DECTA protocol than in the SECTA protocol. Conclusion: DECTA at 40 keV with 50% reduced iodine dose provided higher vascular CT numbers and SNR than SECTA, and almost comparable arterial depiction, but had a degraded intrapelvic arterial depiction and required a larger radiation dose. Advances in knowledge: DECTA enables 50% reduction of iodine dose while maintaining image quality, arterial depiction in almost all arteries, vascular CT numbers, and SNR; however, it does not allow clear visualization of intrapelvic arteries, requiring a slightly larger radiation dose compared with SECTA with standard iodine dose.

21 September 2023 in Clinical Cancer Research
Verified
Journal Article
Open access
PDF file
HAHirofumi Asano
Hirofumi Asano
AEAbdelazim Elsayed. Elhelaly
Abdelazim Elsayed. Elhelaly
FHFuminori Hyodo
Fuminori Hyodo
RIRyota Iwasaki
Ryota Iwasaki
YNYoshifumi Noda
Yoshifumi Noda
MMMasayuki Matsuo
Masayuki Matsuo
Purpose: An accurate and noninvasive assessment of tumor response following treatment other than traditional anatomical imaging techniques is essential. Deuterium magnetic resonance spectroscopic (MRS) imaging has been demonstrated as an alternative for cancer metabolic imaging by high-field MRI using deuterium-labeled molecules. The study aim was to use 2H tissue labeling and deuterium MRI at clinical field strength for tumor visualization and assessment of three anticancer therapies in pancreatic cancer model mice. Experimental Design: MIA PaCa-2 pancreatic carcinoma and C26 colorectal carcinoma models of BALB/c-nu mice was prepared, and repeated deuterium MRI was performed during the first 10 days of free drinking of 30% D2O to track 2H distribution in tissues. 2H accumulation in the tumor after irradiation, bevacizumab administration, or gemcitabine administration was also measured in MIA PaCa-2–bearing mice. Confirmatory proton MRI, ex vivo metabolic hyperpolarization 13C-MRS, and histopathology were performed. Results: The mouse's whole-body distribution of 2H was visible 1 day after drinking, and the signal intensity increased daily. Although the tumor size did not change 1 and 3 days after irradiation, the amount of 2H decreased significantly. The 2H image intensity of the tumor also significantly decreased after the administration of bevacizumab or gemcitabine. Metabolic hyperpolarization 13C-MRS, proton MRI, and 2H-NMR spectroscopy confirmed the efficacy of the anticancer treatments. Conclusions: Deuterium MRI at 1.5T proved feasible to track 2H distribution throughout mouse tissues during D2O administration and revealed a higher 2H accumulation in the tumor xenografts. This research demonstrated a promising successful method for preliminary assessment of radiotherapy and chemotherapy of cancer.

16 October 2020 in Analytical Chemistry
Verified
Journal Article
Closed access
SSShinichi Shoda
Shinichi Shoda
FHFuminori Hyodo
Fuminori Hyodo
YTYoko Tachibana
Yoko Tachibana
MKMamoru Kiniwa
Mamoru Kiniwa
TNTatsuya Naganuma
Tatsuya Naganuma
MMMasayuki Matsuo
Masayuki Matsuo