Jacob Levi

Jacob Levi

Auto-generated profile, based on publicly available information

Jacob Levi

Case Western Reserve Univ. (United States)

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2018 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
PDF file
BEBrendan Lee Eck
Brendan Lee Eck
RMRaymond F Muzic
Raymond F Muzic
JLJacob Levi
Jacob Levi
HWHao Wu
Hao Wu
RFRachid Fahmi
Rachid Fahmi
DWDavid L Wilson
David L Wilson
In this work, we clarified the role of acquisition parameters and quantification methods in myocardial blood flow (MBF) estimability for myocardial perfusion imaging using CT (MPI-CT). We used a physiologic model with a CT simulator to generate time-attenuation curves across a range of imaging conditions, i.e. tube current-time product, imaging duration, and temporal sampling, and physiologic conditions, i.e. MBF and arterial input function width. We assessed MBF estimability by precision (interquartile range of MBF estimates) and bias (difference between median MBF estimate and reference MBF) for multiple quantification methods. Methods included: six existing model-based deconvolution models, such as the plug-flow tissue uptake model (PTU), Fermi function model, and single-compartment model (SCM); two proposed robust physiologic models (RPM1, RPM2); model-independent singular value decomposition with Tikhonov regularization determined by the L-curve criterion (LSVD); and maximum upslope (MUP). Simulations show that MBF estimability is most affected by changes in imaging duration for model-based methods and by changes in tube current-time product and sampling interval for model-independent methods. Models with three parameters, i.e. RPM1, RPM2, and SCM, gave least biased and most precise MBF estimates. The average relative bias (precision) for RPM1, RPM2, and SCM was ⩽11% (⩽10%) and the models produced high-quality MBF maps in CT simulated phantom data as well as in a porcine model of coronary artery stenosis. In terms of precision, the methods ranked best-to-worst are: RPM1 > RPM2 > Fermi > SCM > LSVD > MUP other methods. In terms of bias, the models ranked best-to-worst are: SCM > RPM2 > RPM1 > PTU > LSVD other methods. Models with four or more parameters, particularly five-parameter models, had very poor precision (as much as 310% uncertainty) and/or significant bias (as much as 493%) and were sensitive to parameter initialization, thus suggesting the presence of multiple local minima. For improved estimates of MBF from MPI-CT, it is recommended to use reduced models that incorporate prior knowledge of physiology and contrast agent uptake, such as the proposed RPM1 and RPM2 models.

15 March 2019
Verified
Conference Paper
Closed access
PDF file
YSYingnan Song
Yingnan Song
BEBrendan Lee Eck
Brendan Lee Eck
JLJacob Levi
Jacob Levi
DWDavid Wilson
David Wilson
There are multiple quantitative methods for assessing coronary calcifications with CT including Agatston, mass score, and volume score. Several studies have shown mass score in mg-calcium to be the most reproducible. Since we are interested in tracking changes in individual calcifications over time as a new biomarker of vascular disease, we have analyzed ways to further improve reproducibility. The conventional way to calculate calcium mass score is to sum all voxels above 130- HU and convert to mass score using a calibration constant. However, this does not account for CT system blurring or partial volumes in voxels containing both calcification and soft tissue. To improve coronary calcification measurements, we used Richardson-Lucy deconvolution with a measured impulse response (Philips IQon) and/or partial volume correction processing. At 120 kVp, we imaged a phantom with calcium inserts and calcified cadaver hearts at three rotational orientations at high (0.4883-mm, 0.67-mm-thick) and normal clinical (0.4883-mm, 2.5-mm-thick) resolution. Processing improves accuracy as the absolute difference in conventional and processed results is (12.67 mg, 8.29 mg) for conventional resolution image and (7.09 mg, 5.26 mg) for high resolution image respectively across phantom calcium inserts with known values. Deconvolution also increased contrast (and HU) of small calcifications in cadaver hearts. For low resolution images, across rotation angle, average absolute difference, as compared to high resolution images, was improved with processing by 30.8%. Processing also improves reproducibility across rotation angle. Results were similar in virtual 70 keV images.