Asger Dirksen

Asger Dirksen

Auto-generated profile, based on publicly available information

Asger Dirksen

Gentofte Hospital, Copenhagen University, DK-2900 Hellerup, Denmark

Research Focus & Metrics

Academic Career Length

28Years (1999-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 April 2010 in Nature Genetics
Verified
Journal Article
Closed access
PDF file
TCThe ENGAGE Consortium
The ENGAGE Consortium
TTThorgeir E Thorgeirsson
Thorgeir E Thorgeirsson
DGDaniel F Gudbjartsson
Daniel F Gudbjartsson
ISIda Surakka
Ida Surakka
JVJacqueline M Vink
Jacqueline M Vink
KSKari Stefansson
Kari Stefansson

1 November 1999 in American Journal of Respiratory and Critical Care Medicine
Verified
Journal Article
Closed access
ADAsger Dirksen
Asger Dirksen
JDJoop H. Dijkman
Joop H. Dijkman
FMFlemming Madsen
Flemming Madsen
BSBerend Stoel
Berend Stoel
DHDuncan C. S. Hutchison
Duncan C. S. Hutchison
JSJan Stolk
Jan Stolk
We have investigated whether restoration of the balance between neutrophil elastase and its inhibitor, α1-antitrypsin, can prevent the progression of pulmonary emphysema in patients with α1-antitrypsin deficiency. Twenty-six Danish and 30 Dutch ex-smokers with α1-antitrypsin deficiency of PI*ZZ phenotype and moderate emphysema (FEV1 between 30% and 80% of predicted) participated in a double-blind trial of α1-antitrypsin augmentation therapy. The patients were randomized to either α1-antitrypsin (250 mg/kg) or albumin (625 mg/kg) infusions at 4-wk intervals for at least 3 yr. Self-administered spirometry performed every morning and evening at home showed no significant difference in decline of FEV1 between treatment and placebo. Each year, the degree of emphysema was quantified by the 15th percentile point of the lung density histogram derived from computed tomography (CT). The loss of lung tissue measured by CT (mean ± SEM) was 2.6 ± 0.41 g/L/yr for placebo as compared with 1.5 ± 0.41 g/L/yr for α1-antitrypsin infusion (p = 0.07). Power analysis showed that this protective effect would be significant in a similar trial with 130 patients. This is in contrast to calculations based on annual decline of FEV1 showing that 550 patients would be needed to show a 50% reduction of annual decline. We conclude that lung density measurements by CT may facilitate future randomized clinical trials of investigational drugs for a disease in which little progress in therapy has been made in the past 30 yr. Dirksen A, Dijkman JH, Madsen F, Stoel B, Hutchison DCS, Ulrik CS, Skovgaard LT, Kok-Jensen A, Rudolphus A, Seersholm N, Vrooman HA, Reiber JHC, Hansen NC, Heckscher T, Viskum K, Stolk J. A randomized clinical trial of α1-antitrypsin augmentation therapy.

5 February 2009 in European Respiratory Journal
Verified
Journal Article
Open access
PDF file
ADA. Dirksen
A. Dirksen
EPE. Piitulainen
E. Piitulainen
DPD. G. Parr
D. G. Parr
CDC. Deng
C. Deng
MWM. Wencker
M. Wencker
RSR. A. Stockley
R. A. Stockley
Assessment of emphysema-modifying therapy is difficult, but newer outcome measures offer advantages over traditional methods. The EXAcerbations and Computed Tomography scan as Lung End-points (EXACTLE) trial explored the use of computed tomography (CT) densitometry and exacerbations for the assessment of the therapeutic effect of augmentation therapy in subjects with α1-antitrypsin (α1-AT) deficiency.In total, 77 subjects (protease inhibitor type Z) were randomised to weekly infusions of 60 mg·kg−1human α1-AT (Prolastin®) or placebo for 2–2.5 yrs. The primary end-point was change in CT lung density, and an exploratory approach was adopted to identify optimal methodology, including two methods of adjustment for lung volume variability and two statistical approaches. Other end-points were exacerbations, health status and physiological indices.CT was more sensitive than other measures of emphysema progression, and the changes in CT and forced expiratory volume in 1 s were correlated. All methods of densitometric analysis concordantly showed a trend suggestive of treatment benefit (p-values for Prolastin®versusplacebo ranged 0.049–0.084). Exacerbation frequency was unaltered by treatment, but a reduction in exacerbation severity was observed.In patients with α1-AT deficiency, CT is a more sensitive outcome measure of emphysema-modifying therapy than physiology and health status, and demonstrates a trend of treatment benefit from α1-AT augmentation.

5 October 2010 in Respiratory Research
Verified
Journal Article
Open access
PDF file
RSRobert A Stockley
Robert A Stockley
DPDavid Parr
David Parr
EPEeva Piitulainen
Eeva Piitulainen
JSJan Stolk
Jan Stolk
BSBerend C Stoel
Berend C Stoel
ADAsger Dirksen
Asger Dirksen
Two randomised, double-blind, placebo-controlled trials have investigated the efficacy of IV alpha-1 antitrypsin (AAT) augmentation therapy on emphysema progression using CT densitometry.

13 August 2009 in Respiratory Research
Verified
Journal Article
Open access
PDF file
DPDavid Parr
David Parr
ADAsger Dirksen
Asger Dirksen
EPEeva Piitulainen
Eeva Piitulainen
CDChunqin Deng
Chunqin Deng
MWMarion Wencker
Marion Wencker
RSRobert A Stockley
Robert A Stockley
Computed tomography (CT) lung densitometry has been demonstrated to be the most sensitive and specific outcome measure for the assessment of emphysema-modifying therapy, but the optimum densitometric index has yet to be determined and targeted sampling may be more sensitive than whole lung assessment. The EXAcerbations and CT scan as Lung Endpoints (EXACTLE) trial aimed to clarify the optimum approach to the use of CT densitometry data for the assessment of alpha 1-antitrypsin (AAT) augmentation therapy on the progression of emphysema in AAT deficiency (AATD).

15 December 2008 in Proceedings of the American Thoracic Society
Verified
Journal Article
Closed access
ADAsger Dirksen
Asger Dirksen
Emphysema is a major constituent of lung pathology in chronic obstructive pulmonary disease, and emphysema is characterized by loss of lung tissue. Computed tomography (CT) generates detailed information on tissue densities, and lung density by CT has the potential of being both more sensitive and specific for monitoring emphysema in clinical trials than more traditional outcome measures such as pulmonary function tests. However, CT measurements of lung density are subject to many sources of noise, such as variations in the scanning procedure (technical noise) and variations in patient performance (biological noise). A multi-detector array scanner and a low-dose volumetric scanning protocol are recommendable, and images should be reconstructed using a soft filter. In longitudinal studies the percentile density (PD) is the most reproducible densitometric parameter, and confounding due to variations in inspiratory level can be adjusted for by a physiologic model that assumes that the lung behaves like a sponge. Work remains to be done to standardize and validate CT lung density, before it can become established as the primary outcome measure in clinical trials of new treatments for chronic obstructive pulmonary disease.