A 26-year-old woman with partial atrioventricular (AV) canal defect surgically closed with pericardial patch in a mode that the triangle of Koch had become part of the left atrium underwent successful slow pathway ablation for slow–fast AV nodal reentrant tachycardia. Transseptal approach was used because of the atypical post-operative anatomy. Transseptal catheter ablation of the slow pathway can be a reasonable and safe alternative in patients subjected to this type of operation.
При пациенти с рецидивиращ вазовагален синкоп с кардиоинхибиторен или смесен механизъм, или при пациенти със симптомна функционална синусова брадикардия или АV блок може да се приложи кардионевроаблация. Материал и методи: Представяме серия от 5 пациенти – четирима от тях с рецидивиращи синкопи и/или симптомна синусова брадикардия, а петият – с пристъпно предсърдно мъждене и рецидивиращи синкопи. След потвърждение на механизма на синкопа с тилт-тест и след положителен атропинов тест беше извършена радиофреквентна катетърна кардионевроаблация (при пациента с предсърдно мъждене като добавка към изолация на белодробните вени). При краткосрочно проследяване при нито един от пациентите няма рецидив на синкоп. Заключение: Катетърната невромодулация в тази първа в България клинична серия показва много добри краткосрочни резултати и липса на сериозни усложнения. Patients with recurrent vasovagal syncope with cardioinhibitory or mixed mechanism, or with symptomatic functional sinus bradycardia or AV block can be treated with cardioneuroablation. Material and methods: A case series of 5 patients is presented – four with recurrent syncope and/or symptomatic sinus bradycardia, and one with paroxysmal atrial fi brillation and recurrent syncope. After a confi rmation of the syncope mechanism with tilt table test, and after positive atropine test, radiofrequency catheter cardioneuroablation was performed (this was adjunctive procedure for the patient with atrial fi brillation who received pulmonary vein isolation). During short-term follow-up none of the patients had syncopal recurrence. Conclusion: Catheter neuromodulation provided very good short-term results and lack of serious complications in this fi rst case series in Bulgaria.
This study presents data from the national electronic registry BG-EPHY on electrophysiologic (EP) cardiac ablations in 2019 and 2020. Material and methods. This is a retrospective study of a full two-year sample of the BG-EPHY registry. Sex and age distribution of the patients, number of ablations, electroanatomic mapping (EAM), irrigated ablations, distribution of different types of arrhythmia, intraprocedural success and complications are presented. Results. In 2019 four EP laboratories performed 1033 ablations in 652 men (63.1%) and 381 women, incl. 12 pediatric ablations (1.2%). EAM was used in 46.7% of the procedures, irrigation catheter was used in 52.2%, and cryocatheter – in 0.5%. The most common procedure was pulmonary vein isolation, followed by ablation for AV nodal reentrant tachycardia and typical atrial flutter. In 2020 five EP laboratories performed 835 ablations in 508 men (60.8%) and 327 women, incl. 8 pediatric ablations (1%). EAM was used in 50.9% of the ablations, irrigation catheter – in 54.5%, and cryocatheter – in 3.8%. The most common procedure was again pulmonary vein isolation. Ablation of typical atrial flutter was the second most frequently performed procedure, ahead of AV nodal reentrant tachycardia. In 2020 the number of ablations of accessory pathways also distinctly dropped by 37%. In both years the acute success was over 98%, and the complications were less than 2%. Conclusion. The national registry of electrophysiology collects systematically and continuously basic data on all cardiac ablations performed in the country. The structure of the EP service is remarkably similar to other European countries. Acute success is very high, while intraprocedural complications are rare. In 2020 the number of the ablations dropped by 19% as a consequence of the COVID-19 pandemic.
ObjectiveThe non-fluoroscopic navigation (NFN) is known to reduce the fluoroscopic time during catheter ablation of various arrhythmias. We aimed to study the impact of NFN over several procedural parameters during radiofrequency (RF) catheter ablation of the cavo-tricuspid isthmus (CTI) in patients with CTI-dependent atrial flutter. Methods Data about 124 consecutive patients with CTI ablation performed were retrospectively collected. The patients were divided into two groups: (1) ablation with two diagnostic catheters deployed in the coronary sinus and around the tricuspid annulus (NFN–, n = 62); (2) ablation with the same two catheters plus NFN system using cutaneous patches (NFN+, n = 62). Several procedural parameters were analysed. The non-parametric Mann-Whitney test was used for statistical analysis. A P-value <0.05 was considered significant. Results Acute success was achieved in 122 patients (98.4%), recurrences of atrial flutter were observed in 11 patients (8.9%). There were no significant differences between the NFN + and NFN– groups in the procedural duration (169.6 vs 157.6 min) and the recurrences (6.5 vs 11.3%). In the NFN + group the fluoroscopic time was shorter (9.4 vs 16.7 min), DAP was lower (2,128.3 vs 4,129.9 μGy*m2), the total RF time was shorter (1,870.5 vs 2,335.5 sec), Р < 0.05 for all parameters. Conclusions NFN reduces significantly not only the x-ray exposure but the total RF time as well. It does not influence the procedural duration and the recurrence rate. The acute and long-term success of catheter ablation of CTI is high irrespective of the use of NFN.