Martin Biallas

Martin Biallas

Auto-generated profile, based on publicly available information

Martin Biallas

Lucerne University of Applied Sciences and Arts

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

1 February 2010 in SLEEP
Verified
Journal Article
Open access
PDF file
FPFabio Pizza
Fabio Pizza
MBMartin Biallas
Martin Biallas
MWMartin Wolf
Martin Wolf
EWEsther Werth
Esther Werth
CBClaudio L. Bassetti
Claudio L. Bassetti
Sleep disordered breathing (SDB) of the obstructive type causes hemodynamic consequences, leading to an increased cerebrovascular risk. The severity of SDB at which detrimental circulatory consequences appear is matter of controversy. Aim of the present study is the investigation of cerebral hemodynamics in patients with SDB of variable severity using near-infrared spectroscopy (NIRS). N/A. Sleep laboratory. Nineteen patients with SDB. N/A Patients underwent nocturnal videopolysomnography (VPSG) coupled with cerebral NIRS. NIRS data were averaged for each patient, and a new method (integral) was applied to quantify cerebral hemodynamic alterations. Nocturnal VPSG disclosed various severities of SDB: snoring (7 patients, apnea-hypopnea index [AHI] = 2 ± 2/h, range: 0.5–4.5); mild SDB (7 patients, AHI = 14 ± 8/h, range: 6.3– 28.6); and severe obstructive sleep apnea syndrome (5 patients, AHI = 79 ± 20/h, range: 39.6–92.9). Relative changes of NIRS parameters were significantly larger during obstructive apneas (compared with hypopneas; mean deoxygenated hemoglobin [HHb] change of 0.72 ± 0.23 and 0.13 ± 0.08 umol/L per sec, p value = 0.048) and in patients with severe SDB (as compared with patients with mild SDB and simple snorers; mean HHb change of 0.84 ± 0.24, 0.02 ± 0.09, and 0.2 ± 0.08 umol/L per sec, respectively, p value = 0.020). In this group, NIRS and concomitant changes in peripheral oxygen saturation correlated. The results of this study suggest that acute cerebral hemodynamic consequences of SDB lead to a failure of autoregulatory mechanisms with brain hypoxia only in the presence of frequent apneas (AHI > 30) and obstructive events.

1 January 2011 in Journal of Biomedical Optics
Verified
Journal Article
Closed access
PDF file
SASandra Jasminder Arri
Sandra Jasminder Arri
TMThomas Muehlemann
Thomas Muehlemann
MBMartin Biallas
Martin Biallas
HBHans Ulrich Bucher
Hans Ulrich Bucher
MWMartin Wolf
Martin Wolf
Background and aim: One source of error with near-infrared spectroscopy (NIRS) is the assumption that the measured tissue is optically homogeneous. This is not always the case. Our aim is to assess the impact of tissue homogeneity (TH) on the precision of NIRS measurements in neonates. Methods: On 36 term and 27 preterm neonates at least five 1-min measurements are performed on each subject using the OxiplexTS. The sensor position is slightly changed before each measurement while assessing TH. The precision for cerebral tissue oxygenation saturation (StO2) and total hemoglobin concentration (tHb) are calculated by repeated measures analysis of variance. Results: The mean StO2 is not significantly different between term and preterm infants. The mean tHb is significantly lower in preterm infants (p < 0.01). With increasing TH, the precision of StO2 increase from 5.6 to 4.6% for preterm and from 11.0 to 2.0% for term infants; the precision of tHb increases from 10.1 to 7.5μM for preterm and from 16.4 to 3.5μM for term infants. The precision for StO2 is higher in term than in preterm infants. The precision for tHb shows no significant difference between the two groups. Conclusions: The precision of NIRS measurements correlates with tissue homogeneity.

1 July 2012 in Stroke
Verified
Journal Article
Closed access
PDF file
FPFabio Pizza
Fabio Pizza
MBMartin Biallas
Martin Biallas
UKUlf Kallweit
Ulf Kallweit
MWMartin Wolf
Martin Wolf
CBClaudio L. Bassetti
Claudio L. Bassetti
Background and Purpose—: Sleep-disordered breathing (SDB) negatively impacts stroke outcome. Near-infrared spectroscopy showed the acute cerebral hemodynamic effects of SDB. Methods—: Eleven patients (7 men, age 61±13 years) with acute/subacute middle cerebral artery stroke (National Institutes of Health Stroke Scale score 10±7) and SDB (apnea–hypopnea index 32±28/hour) were assessed with nocturnal polysomnography and bilateral near-infrared spectroscopy recording. Cerebral oxygenation and hemoglobin concentration changes during obstructive and central apneas were analyzed. Results—: During SDB, near-infrared spectroscopy showed asymmetrical patterns of cerebral oxygenation and hemoglobin concentrations with changes significantly larger on the unaffected compared with the affected hemisphere. Brain tissue hypoxia was more severe during obstructive compared with central apneas. Conclusions—: Profound cerebral deoxygenation effects of SDB occurred in acute/subacute stroke. These changes may contribute to poor outcome, arising in the possibility of a potential benefit of SDB treatment in stroke management.

1 January 2011 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
CJCarmen Jenny
Carmen Jenny
MBMartin Biallas
Martin Biallas
ITIvo Trajkovic
Ivo Trajkovic
JFJean-Claude Fauchère
Jean-Claude Fauchère
HBHans Ulrich Bucher
Hans Ulrich Bucher
MWMartin Wolf
Martin Wolf
The interaction between light and biological tissue is determined by the intensity and wavelength of the light and by the optical properties (absorption and scattering) of the tissue. Biological tissues can be penetrated relatively deeply by near-infrared (NIR) light, and thus the brain can be studied. In the present work NIR-LEDs (light-emitting diodes) are used to couple light into the head tissue. The light is strongly scattered, because the brain is a strong scatterer in the NIR.1, 2 The intensity of the re-emerging light is measured by a photodiode detector, and thus the optical properties of the brain can be obtained. Every tissue also has its own absorption spectrum. Biological tissues contain three main absorbers: water, hemoglobin, and lipid. Below a wavelength of 650 nm, strong absorption occurs for oxyhemoglobin (O2Hb) and deoxyhemoglobin (HHb), whereas water shows strong absorption above 950 nm. As a consequence of this, light does not penetrate deeply into the tissue in these regions. To be able to interrogate deep layers of tissue, near-infrared spectroscopy (NIRS) uses NIR wavelengths between 650 and 950 nm. NIRS is primarily employed to measure tissue oxygenation with parameters such as O2Hb, HHb, total hemoglobin (tHb) concentration, tissue oxygen saturation (StO2), and cerebral blood flow.3 NIRS has the advantage to enable bedside continuous and noninvasive monitoring of these parameters. Furthermore, it can be combined with other types of cerebral monitoring such as EEG or aEEG, and it is cost effective.2

1 June 2015
Verified
Conference Paper
Closed access
JRJacek Ruminski
Jacek Ruminski
MSMaciej Smiatacz
Maciej Smiatacz
ABAdam Bujnowski
Adam Bujnowski
AAAliaksei Andrushevich
Aliaksei Andrushevich
MBMartin Biallas
Martin Biallas
RKRolf Kistler
Rolf Kistler
Recently, different smart glasses solutions have been proposed on the market. The rapid development of this wearable technology has led to several research projects related to applications of smart glasses in healthcare. In this paper we propose a general architecture of the system enabling data integration for the recognized person. In the proposed system smart glasses integrates data obtained for the recognized patient from health care information systems, from devices connected to the patient and from the patient himself. The data integration is possible, if proper patient recognition procedure is used. Therefore, we evaluated three identification methods based on face recognition and using the recognition of graphical markers (i.e. QR-codes and proposed color-based codes). The results show that it is possible to obtain reliable and fast recognition results during the video acquisition by the smart glasses camera.