Soumya Gupta

Soumya Gupta

Auto-generated profile, based on publicly available information

Soumya Gupta

Department of Medicine Icahn School of Medicine at Mount Sinai Morningside/West‐ New York New York NY

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 February 2024 in Journal of the American Heart Association
Verified
Journal Article
Open access
AKArpanjeet Kaur
Arpanjeet Kaur
ADArshdeep S. Dhaliwal
Arshdeep S. Dhaliwal
SSSumit Sohal
Sumit Sohal
YGYeongjin Gwon
Yeongjin Gwon
SGSoumya Gupta
Soumya Gupta
JTJacqueline Tamis‐Holland
Jacqueline Tamis‐Holland
Background: Cerebral embolic protection devices (CEPD) capture embolic material in an attempt to reduce ischemic brain injury during transcatheter aortic valve replacement. Prior reports have indicated mixed results regarding the benefits of these devices. With new data emerging, we performed an updated meta‐analysis examining the effect of CEPD during transcatheter aortic valve replacement on various clinical, neurological, and safety parameters. Methods and Results: A comprehensive review of electronic databases was performed comparing CEPD and no‐CEPD in transcatheter aortic valve replacement. Primary clinical outcome was all‐cause stroke. Secondary clinical outcomes were disabling stroke and all‐cause mortality. Neurological outcomes included worsening of the National Institutes of Health Stroke Scale score, Montreal Cognitive Assessment score from baseline at discharge, presence of new ischemic lesions, and total lesion volume on neuroimaging. Safety outcomes included major or minor vascular complications and stage 2 or 3 acute kidney injury. Seven randomized controlled trials with 4016 patients met the inclusion criteria. There was no statistically significant difference in the primary clinical outcome of all‐cause stroke; secondary clinical outcomes of disabling stroke, all‐cause mortality, neurological outcomes of National Institutes of Health Stroke Scale score worsening, Montreal Cognitive Assessment worsening, presence of new ischemic lesions, or total lesion volume on diffusion‐weighted magnetic resonance imaging between CEPD versus control groups. There was no statistically significant difference in major or minor vascular complications or stage 2 or 3 acute kidney injury between the groups. Conclusions: The use of CEPD in transcatheter aortic valve replacement was not associated with a statistically significant reduction in the risk of clinical, neurological, and safety outcomes.