1 March 2019 in Scientific Reports
Intracellular delivery of functional macromolecules, such as DNA and RNA, across the cell membrane and into the cytosol, is a critical process in both biology and medicine. Herein, we develop and use microfluidic chips containing post arrays to induce microfluidic vortex shedding, or μVS, for cell membrane poration that permits delivery of mRNA into primary human T lymphocytes. We demonstrate transfection with μVS by delivery of a 996-nucleotide mRNA construct encoding enhanced green fluorescent protein (EGFP) and assessed transfection efficiencies by quantifying levels of EGFP protein expression. We achieved high transfection efficiency (63.6 ± 3.44% EGFP + viable cells) with high cell viability (77.3 ± 0.58%) and recovery (88.7 ± 3.21%) in CD3 + T cells 19 hrs after μVS processing. Importantly, we show that processing cells via μVS does not negatively affect cell growth rates or alter cell states. We also demonstrate processing speeds of greater than 2.0 × 106 cells s−1 at volumes ranging from 0.1 to 1.5 milliliters. Altogether, these results highlight the use of μVS as a rapid and gentle delivery method with promising potential to engineer primary human cells for research and clinical applications.
1 January 2020 in MethodsX
This method describes a novel approach to systematically investigate the effect of the fluid shear stress (FSS) on epithelial cells thanks to a single microfluidic device based on Hele-Shaw geometry. The method was validated with intestinal Caco-2 cell monolayers and lung A549 cells. We provide guidelines to adjust the experimental parameters to apply specific ranges of FSS and to specify more accurately the area where to image the cells within the device by the performance of a computational simulation of the fluid flow. Most importantly, this simulation enables to validate the equation. This approach was successfully applied to systematically investigate Caco-2 cell monolayers-based intestine-on-chip models as reported in a companion article published in Biomaterials. This study showed that exposure to microfluidic FSS induces significant phenotypical and functional changes. A detailed understanding of the effects of the FSS will enable the realization of in vitro organs-on-chip models with well-defined characteristics tailored to a specific purpose. The Hele-Shaw approach used in this study could be readily applied to other cell types and adapted for a wide range of physiologically relevant FSS.•Fluid shear stress is a key parameter in the differentiation of epithelial cells cultured in organ-on-chip models.•A simple approach can be used to assess the effect of fluid shear on cellular monolayer cultured in microfluidic devices.•Careful optimization of fluid shear stress environment is necessary for the development of better-defined organ-on-chip models.•Computational simulation of the fluid flow gives an accurate definition of the FSS in a microfluidic channel necessary to interpret the results.
1 March 2023 in Biomicrofluidics
Microfluidics devices are gaining significant interest in biomedical applications. However, in a micron-scale device, reaction speed is often limited by the slow rate of diffusion of the reagents. Several active and passive micro-mixers have been fabricated to enhance mixing in microfluidic devices. Here, we demonstrate external control of mixing by rotating a rod-shaped bacterial cell. This rotation is driven by ion transit across the bacterial flagellar stator complex. We first measured the flow fields generated by rotating a single bacterial cell rotationally locked to rotate either clockwise (CW) or counterclockwise (CCW). Micro-particle image velocimetry (μPIV) and particle tracking velocimetry results showed that a bacterial cell of ∼ 2.75 μm long, rotating at 5.75 ± 0.39 Hz in a counterclockwise direction could generate distinct micro-vortices with circular flow fields with a mean velocity of 4.72 ± 1.67 μm/s and maximum velocity of 7.90 μm/s in aqueous solution. We verified our experimental data with a numerical simulation at matched flow conditions, which revealed vortices of similar dimensions and speed. We observed that the flow-field diminished with increasing z-height above the plane of the rotating cell. Lastly, we showed that we could activate and tune rotational mixing remotely using strains engineered with proteorhodopsin, where rotation could be activated by controlled external illumination using green laser light (561 nm).
1 May 2021 in Biomicrofluidics
Many motile bacteria are propelled by the rotation of flagellar filaments. This rotation is driven by a membrane protein known as the stator-complex, which drives the rotor of the bacterial flagellar motor. Torque generation is powered in most cases by proton transit through membrane protein complexes known as stators, with the next most common ionic power source being sodium. Sodium-powered stators can be studied through the use of synthetic chimeric stators that combine parts of sodium- and proton-powered stator proteins. The most well studied example is the use of the sodium-powered PomA-PotB chimeric stator unit in the naturally proton-powered Escherichia coli. Here we designed a fluidics system at low cost for rapid prototyping to separate motile and non-motile populations of bacteria while varying the ionic composition of the media and thus the sodium-motive force available to drive this chimeric flagellar motor. We measured separation efficiencies at varying ionic concentrations and confirmed using fluorescence that our device delivered eightfold enrichment of the motile proportion of a mixed population. Furthermore, our results showed that we could select bacteria from reservoirs where sodium was not initially present. Overall, this technique can be used to implement the selection of highly motile fractions from mixed liquid cultures, with applications in directed evolution to investigate the adaptation of motility in bacterial ecosystems.
20 February 2020 in Microfluidics and Nanofluidics