This study aimed to investigate the release of common monomers from two conventional and two bisphenol A (BPA)‐free temporary crown and bridge materials. Cylindrical samples of all materials were prepared (N = 90; five samples for each material and cycle of analysis). All samples were immersed in high‐performance liquid chromatography (HPLC)‐grade water and incubated for 1 h, 12 h, 24 h, and 7 days in an incubation shaker at 37°C and 112 rpm. Extraction was performed in accordance with ISO 10993‐12. Eluted monomers were detected and quantified by HPLC coupled with ultraviolet–visible spectroscopy and mass spectrometry (HPLC‐UV/Vis‐MS). Analysis of BPA was performed by HPLC coupled with ultraviolet–visible spectroscopy (HPLC‐UV/Vis) and positive results were verified by HPLC‐tandem mass spectrometry (HPLC‐MS/MS). Neither bisphenol A‐glycidyl methacrylate (Bis‐GMA) nor BPA was quantifiable in any of the crown and bridge samples investigated in the present study. However, all samples contained triethylene glycol dimethacrylate (TEGDMA) and/or urethane dimethacrylate (UDMA) after 24 h of incubation. Statistical analysis showed that significantly more UDMA was released from the BPA‐free materials than from the conventional materials. All concentrations of UDMA measured were below the effective cytotoxic concentrations previously reported. However, for a few materials, especially BPA‐free temporary crown and bridge materials, the levels of UDMA were above previously reported potentially harmful concentrations for local cells. As BPA‐free materials were introduced as being more biocompatible than materials containing BPA, substitution of Bis‐GMA with UDMA should be further investigated.

1 August 2016 in Journal of Cranio-Maxillofacial Surgery
Verified
Journal Article
Closed access
Phillipp BrockmeyerPhillipp Brockmeyer
Phillipp Brockmeyer
SKSebastian Krohn
Sebastian Krohn
CTCharlotte Thiemann
Charlotte Thiemann
XSXenia Schulz
Xenia Schulz
PKPhilipp Kauffmann
Philipp Kauffmann
RGRudolf Matthias Gruber
Rudolf Matthias Gruber

22 May 2024 in European Journal of Oral Sciences
Verified
Journal Article
Open access
THTristan Hampe
Tristan Hampe
JLJulia Liersch
Julia Liersch
BWBernhard Wiechens
Bernhard Wiechens
RBRalf Bürgers
Ralf Bürgers
SKSebastian Krohn
Sebastian Krohn
This study aimed to investigate the bisphenol A (BPA) release from four CAD/CAM splint materials: three polycarbonate‐based (DD BioSplint C, Splint Plus Biostar, Temp Premium Flexible) and one polymethylmethacrylate‐based (Temp Basic) material. From each material, ten cylindrical samples (n = 40) were immersed in high‐performance liquid chromatography (HPLC) grade water following ISO 10993‐12 and incubated for 24 h in an incubation shaker at 37°C and 112 rpm. Following BPA derivatization, analysis was performed by high‐performance liquid chromatography–tandem mass spectrometry (HPLC‐MS/MS). After 24 h of incubation, all investigated materials released significant amounts of BPA compared to water blanks. The material‐dependent elution increased in the following order: DD BioSplint C < Splint Plus Biostar < Temp Basic < Temp Premium Flexible. Subtracting extraneous BPA, the concentrations ranged between 2.27 ng/mL and 12.65 ng/mL. After extrapolating the concentrations in relation to the average surface area of occlusal splints, the amount of BPA per mL exceeded the Tolerable Daily Intake (TDI) set by the European Union for a person weighing 70 kg by 1.32–6.16 times. Contrary to the release from previously investigated materials, BPA elution from CAD/CAM splint materials was highly elevated. Considering the increasing adaptation of CAD/CAM techniques, elution from them may represent a relevant BPA source in daily dental practice.

1 June 2023 in Informationen aus Orthodontie & Kieferorthopädie
Verified
Journal Article
Closed access
PDF file
EPEva Paddenberg-Schubert
Eva Paddenberg-Schubert
HHHelmut Hösl
Helmut Hösl
Peter ProffPeter Proff
Peter Proff
SKSebastian Krohn
Sebastian Krohn
Video 1 Beispielhafte Durchführung einer Kieferrelationsbestimmung zur Festlegung der Startposition von Unterkiefer-Protrusionsschienen. Unterkieferprotrusionsschienen (UPS), welche ein bimaxilläres, individuell hergestelltes und nachjustierbares Gerät darstellen, sind zur Therapie der primären Ronchopathie und des leichten bis mittelgradigen Obstruktiven Schlafapnoe Syndroms (OSAS) indiziert [1] [2] [3] [4]. Durch den Protrusionsmechanismus der Schiene wird eine Rückverlagerung des Unterkiefers während des Schlafens verhindert, sodass die Atemwege im Bereich der Epiglottis, des Velums und des Zungengrundes stabilisiert werden [3]. Dieses Prinzip wurde bereits im 19. Jahrhundert zur Anfertigung von Apparaturen berücksichtigt und stetig technisch weiter entwickelt, sodass heutzutage eine Vielzahl an UPS-Schienen (und Bissregistriersystemen) zur Verfügung stehen [5]. Einen weiteren Fortschritt stellte die Aufnahme der UPS in den Leistungskatalog der GKV-Versorgung am 01.01.2022 dar, seitdem die UPS als Zweitlinientherapie für OSAS-Patienten zugelassen ist, wenn eine Überdrucktherapie nicht erfolgreich durchgeführt werden kann [6] [7]. Ein wesentlicher Bestandteil im Herstellungsprozess der UPS ist das Protrusionsregistrat, welches die initial therapeutisch angestrebte Zielposition der UPS definiert. Zu diesem Thema liefert die 2021 publizierte S1-Leitlinie „Die Unterkieferprotrusionsschiene (UPS): Anwendung in der zahnärztlichen Schlafmedizin beim Erwachsenen“ evidenzbasiert Empfehlungen [3]. Das Ziel dieser Arbeit besteht darin, die praktische Vorgehensweise während der Kieferrelationsbestimmung zur Festlegung der Startposition einer UPS in Anlehnung an die entsprechende S1-Leitlinie zu erläutern. Dabei wird das Procedere der Poliklinik für Kieferorthopädie des Universitätsklinikums Regensburg beschrieben und somit das Bissgabelsystem „Bite Fix“ der Firma Scheu Dental vorgestellt, wenngleich eine Vielzahl unterschiedlicher Bissregistriersysteme zur Verfügung steht. Article published online: 01 August 2023 © 2023. Thieme. All rights reserved. Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany