The generation of an analytically useful volatile form of Au has been studied. The flow injection generation was performed in a dedicated generator consisting of a special mixing apparatus and gas–liquid separator design in the presence of surfactants (Triton X-100, Antifoam B) and diethyldithiocarbamate. The on-line atomization in the quartz tube multiatomizer for atomic absorption (AAS) detection has been employed as the convenient atomization/detection means. The optimization of generation and atomization conditions resulted in an analytical procedure yielding the detection limit of 17 ng ml−1 and a very good long range reproducibility of the analytical signal. A 198,199Au radioactive indicator of high specific activity together with AAS measurements was used to track quantitatively the transfer of analyte in the course of generation and transport to the atomizer and to determine the generation efficiency of 11.9 ± 0.1% at the Ar carrier flow rate optimized for the multiatomizer of 240 ml min−1. The efficiency was twice as high at the Ar carrier flow rate of 600 ml min−1. In situ trapping in GF for AAS was explored as an alternative to the on-line atomization. The detection limit of 3.0 ng ml−1 was achieved even though the Ar flow rate optimum for trapping (115 ml min−1) was too low for efficient generation: the overall efficiency of generation and trapping was 1.11 ± 0.03%. Transmission electron microscopy measurements proved the presence of Au nanoparticles of diameter of approximately 10 nm and smaller transported from the generator by the flow of carrier Ar.
8 December 2005 in Journal of Analytical Atomic Spectrometry
A modification of the externally heated quartz tube atomizer, making possible in situ trapping of bismuthine, is described. The very simple experimental set-up is thus capable of lossless collection at a high preconcentration ratio. The collection/volatilization efficiency is 100 ± 2.5%. For a collection time of 300 s (sample volume of 20 ml), the preconcentration ratio and detection limit (3σ), respectively, are 530 and 3.9 pg ml−1. The same approach is analytically useful also for stibine but not for arsine.
9 January 2004 in Journal of Analytical Atomic Spectrometry
A preliminary evaluation of a simple (bare) quartz tube trap for collection of SbH3 and for volatilization of trapped analyte with subsequent atomization in a multiple microflame quartz tube atomizer (multiatomizer) for atomic absorption spectrometry is presented. The influence of relevant experimental parameters on the collection/volatilization efficiency was investigated. The parameters studied were: collection temperature and time, volatilization temperature and flow rates of air and hydrogen for the volatilization. Under optimized conditions, the collection/volatilization efficiency was 65%. For the collection time of 120 s (sample volume of 8 ml), the detection limit was 3.9 pg ml−1, and the analytical plot was linear up to 1.25 ng ml−1. Possible ways of improving the performance of the set-up as well as the collection/volatilization efficiency are suggested.