Xin Liu

Xin Liu

Auto-generated profile, based on publicly available information

Xin Liu

Department of Mining and Nuclear, Missouri University of Science and Technology, Rolla, USA

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 June 2015 in Medical Physics
Verified
Journal Article
Closed access
PDF file
ENEdward T. Norris
Edward T. Norris
XLXin Liu
Xin Liu
JHJiang Hsieh
Jiang Hsieh

21 September 2015 in Journal of X-Ray Science and Technology
Verified
Journal Article
Closed access
PDF file
XLXin Liu
Xin Liu
JHJiang Hsieh
Jiang Hsieh
Knowledge of scatter generated by bowtie filter (i.e. x-ray beam compensator) is crucial for providing artifact free images on the CT scanners. Our approach is to use a hybrid deterministic-stochastic simulation to estimate the scatter level generate

23 November 2015 in Biomedical Physics & Engineering Express
Verified
Journal Article
Closed access
PDF file
HSHuseyin Sahiner
Huseyin Sahiner
ASAnjali Srivastava
Anjali Srivastava
CMCynthia H McCollough
Cynthia H McCollough
XLXin Liu
Xin Liu
Mechanistic questions regarding kidney stone formation have led researchers to look for the presence of trace elements. Neutron activation analysis is able to identify elements at parts-per-million concentrations. Four different types of kidney stones were irradiated with thermal neutrons to produce radioisotopes. Gamma spectroscopy of samples at different counting times was used to reduce identification errors by correlating results with the half-life of identified elements. For more precise identification, Monte Carlo simulation was used to cross-check the identification process. The simulation showed promising results that could lead to fast and accurate identification of trace elements as the simulation code is improved. Sodium (Na), potassium (K), calcium (Ca), bromine (Br), samarium (Sm), zinc (Zn), cadmium (Cd), ytterbium (Yb), gold (Au), cobalt (Co), and manganese (Mn) were identified as being present in the stones, by both the experimentally measured gamma spectrum and the simulation. Among these, Ca, Br, and Zn were found to be of potential clinical relevance via a literature review. Concentrations of the elements were compared to those noted in the literature. For uric acid stones, a correlation with the literature was found for Zn and Ca. A negative correlation was found between Zn and Br for non-uric acid stones. More samples are needed to test for statistical significance.

14 July 2020 in Scientific Reports
Verified
Journal Article
Open access
PDF file
ENEdward T. Norris
Edward T. Norris
XLXin Liu
Xin Liu
In this study, cone-beam single projection and axial CT scans are modeled with a software package—DOCTORS, which solves the linear Boltzmann equation using the discrete ordinates method. Phantoms include a uniform 35 cm diameter water cylinder and a non-uniform abdomen phantom. Series simulations were performed with different simulation parameters, including the number of quadrature angles, the order of Legendre polynomial expansions, and coarse and fine mesh grid. Monte Carlo simulations were also performed to benchmark DOCTORS simulations. A quantitative comparison was made between the simulation results obtained using DOCTORS and Monte Carlo methods. The deterministic simulation was in good agreement with the Monte Carlo simulation on dose estimation, with a root-mean-square-deviation difference of around 2.87%. It was found that the contribution of uncollided photon fluence directly from the source dominates the local absorbed dose in the diagnostic X-ray energy range. The uncollided photon fluence can be calculated accurately using a ‘ray-tracing’ algorithm. The accuracy of collided photon fluence estimation is largely affected by the pre-calculated multigroup cross-sections. The primary benefit of DOCTORS lies in its rapid computation speed. Using DOCTORS, parallel computing with GPU enables the cone-beam CT dose estimation nearly in real-time.

1 January 2014 in Journal of X-Ray Science and Technology
Verified
Journal Article
Closed access
PDF file
XLXin Liu
Xin Liu
HLHyoung Koo Lee
Hyoung Koo Lee
BACKGROUND: While spectral CT using single photon counting detector has shown a number of advantages in diagnostic imaging, knowledge of the detector response function of an energy-resolved detector is needed to correct the signal bias and reconstruc

1 January 2014 in Journal of X-Ray Science and Technology
Verified
Journal Article
Closed access
XLXin Liu
Xin Liu
This study describes a deterministic method for simulating the first-order scattering in a medical computed tomography scanner. The method was developed based on a physics model of x-ray photon interactions with matter and a ray tracing technique. The results from simulated scattering were compared to the ones from an actual scattering measurement. Two phantoms with homogeneous and heterogeneous material distributions were used in the scattering simulation and measurement. It was found that the simulated scatter profile was in agreement with the measurement result, with an average difference of 25% or less. Finally, tomographic images with artifacts caused by scatter were corrected based on the simulated scatter profiles. The image quality improved significantly.