Jinghai Guo

Jinghai Guo

Auto-generated profile, based on publicly available information

Jinghai Guo

Zhejiang Key Laboratory of Intelligent Electromagnetic Control and Advanced Electronic Integration, College of Information Science and Electronic Engineering, Zhejiang University, Hangzhou, China

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 February 2024 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
LZLing Zhang
Ling Zhang
YXYuting Xie
Yuting Xie
YFYu-Ru Feng
Yu-Ru Feng
HMHanzhi Ma
Hanzhi Ma
JGJinghai Guo
Jinghai Guo
ELEr-Ping Li
Er-Ping Li
This article presents a novel and efficient near-field scanning method for coupling path visualization of conductive electromagnetic interference (EMI) using sparse scanning samples based on active machine learning. A high-voltage discharge system with a false triggering problem is studied as the device under test (DUT). Near-field scanning is adopted to measure the time-domain waveform of the conductive current and investigate the coupling path of the conductive EMI that causes the false triggering issue. To facilitate the time-consuming near-field scanning process, an adaptive sampling approach based on active learning is proposed to seek the most informative locations and minimize the number of scanning samples. Through the developed active learning method, the scanning process is more efficient and intelligent than random sampling and a uniform-like sampling strategy called greedy sampling. Moreover, the dominant EMI coupling path in a key area is clearly visualized. By cutting off the identified coupling path, the false triggering phenomenon is effectively eliminated. The proposed active learning method is much more efficient than the conventional full scanning, and can be applied to expedite various near-field scanning scenarios.

6 February 2026 in IEEE Transactions on Antennas and Propagation
Verified
Journal Article
Closed access
JGJinghai Guo
Jinghai Guo
LZLing Zhang
Ling Zhang
Electromagnetic radiation source imaging and localization are crucial to the diagnostics of electromagnetic interference (EMI) problems in complex electronic devices and systems, but are usually a time-consuming and tedious process. This article presents a novel and automatic method based on active and unsupervised machine learning for the rapid localization of EMI sources using the sparse emission source microscopy (ESM) technique. The query-by-committee (QBC) method is adopted to select sparse scan samples with high uncertainties on a scanning plane. A real-time source image is reconstructed on the device-under-test (DUT) plane using the ESM method. Also, a K-means clustering (KMC) method is used to automatically identify the number and locations of EMI sources, and automatically determine when the scanning process can be terminated. The results of simulation and measurement examples show that the proposed method is much more time-efficient compared with the conventional full-scanning ESM method, and can automatically identify the number and locations of the dominant EMI sources without human intervention. Also, the method demonstrates a noticeable advantage over two commonly used sparse scanning methods, including greedy sampling and random sampling, with more clear reconstructed EMI source images with the same number of sparse scanning samples.