Alfred Michael Franz

Alfred Michael Franz

Auto-generated profile, based on publicly available information

Alfred Michael Franz

Institute for Medical Engineering and Mechatronics, University of Applied Sciences, Ulm, Ulm, Germany

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 May 2011 in International Journal of Computer Assisted Radiology and Surgery
Verified
Journal Article
Closed access
PDF file
ASAlexander Seitel
Alexander Seitel
KYKwong Yung
Kwong Yung
SMSven Mersmann
Sven Mersmann
TKThomas Kilgus
Thomas Kilgus
AGAnja Groch
Anja Groch
LMLena Maier-Hein
Lena Maier-Hein

14 April 2023 in Endoscopy
Verified
Journal Article
Closed access
BWBenjamin L Walter
Benjamin L Walter
ASA. Sheikani
A. Sheikani
NSNiklas Sturm
Niklas Sturm
AKAlexander Kleger
Alexander Kleger
Martin MullerMartin Muller
Martin Muller
AFA. Franz
A. Franz
Aims Endoscopic necrosectomy is the favored minimal invasive approach for necrotizing pancreatitis. Even experienced endoscopists are challenged to transfer information from CT-scan into endoscopic location and orientation because visual information about necrotic mass and surrounding structures are not primarily visible. Methods A 3D-printed phantom was built based on segmented CT-scans. An electromagnetic (EM) sensor was integrated into the endoscope’s working channel to localize it by EM-tracking. A custom software-prototype based on the Medical-Imaging-Interaction-Toolkit (MITK, www.mitk.org) was developed which provides a 3D-visualization of necrosis and surrounding organs by a point-based registration of CT data to the endoscopic scene in tracking coordinates.An ex-vivo experiment was conducted. Six experimental runs were conducted by four interventional endoscopists. Supported by the 3D-visualization, each user adressed seven targets spread inside the phantom. Afterwards the Euclidean distance between final position and registered target in tracking coordinates was determined and additionally checked visually. Results All users managed to reach the targets with mean error ranging between (2.6–6.5mm). The endoscope image showed a visual match of the 3D-navigation scene, without problems in registration accuracy. Users’ feedback regarding usefulness and realistic implementation was very positive. Conclusions Although the results are very preliminary, the 3D-approach could have big potential for future clinical use. Article published online: 14 April 2023 © 2023. European Society of Gastrointestinal Endoscopy. All rights reserved. Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany

1 January 2016
Verified
Book Chapter
Closed access
PDF file
NBNasrin Bopp
Nasrin Bopp
AFAlfred Michael Franz
Alfred Michael Franz
DCDominique Cheray
Dominique Cheray
Stefan DelormeStefan Delorme
Stefan Delorme
HKHüdayi Korkusuz
Hüdayi Korkusuz
LMLena Maier-Hein
Lena Maier-Hein

16 March 2012
Verified
Book Chapter
Closed access
PDF file
ASA. Seitel
A. Seitel
MSM. Servatius
M. Servatius
AFA. M. Franz
A. M. Franz
TKT. Kilgus
T. Kilgus
NBN. Bellemann
N. Bellemann
LMLena Maier-Hein
Lena Maier-Hein