Sieu K. Khuu

Sieu K. Khuu

Auto-generated profile, based on publicly available information

Sieu K. Khuu

University of New South Wales

Research Focus & Metrics

Academic Career Length

26Years (2001-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2017 in Clinical and Experimental Optometry
Verified
Journal Article
Open access
JPJack Phu
Jack Phu
SKSieu K Khuu
Sieu K Khuu
MYMichael Yapp
Michael Yapp
NANagi Assaad
Nagi Assaad
MHMichael P Hennessy
Michael P Hennessy
MKMichael Kalloniatis
Michael Kalloniatis
White‐on‐white standard automated perimetry (SAP) is widely used in clinical and research settings for assessment of contrast sensitivity using incremental light stimuli across the visual field. It...

1 December 2019 in American Journal of Ophthalmology
Verified
Journal Article
Open access
JPJack Phu
Jack Phu
SKSieu K. Khuu
Sieu K. Khuu
AAAshish Agar
Ashish Agar
MKMichael Kalloniatis
Michael Kalloniatis
To compare the visual fields results obtained using the Swedish interactive thresholding algorithm-Standard (SS) and the Swedish interactive thresholding algorithm-Faster (SFR) in normal subjects, glaucoma suspects, and patients with glaucoma and to quantify potential time-saving benefits of the SFR algorithm. Prospective, cross-sectional study. One randomly selected eye from 364 patients (77 normal subjects, 178 glaucoma suspects, and 109 patients with glaucoma) seen in a single institution underwent testing using both SS and SFR on the Humphrey Field Analyzer. Cumulative test time using each algorithm was compared after accounting for different rates of test reliability. Pointwise and cluster analysis was performed to determine whether there were systematic differences between algorithms. Using SFR had a greater rate of unreliable results (29.3%) compared with SS (7.7%, P < .0001). This was mainly because of high false positive rates and seeding point errors. However, modeled test times showed that using SFR could obtain a greater number of reliable results within a shorter period of time. SFR resulted in higher sensitivity values (on average 0.5 dB for patients with glaucoma) that was greater under conditions of field loss (<19 dB). Cluster analysis showed no systematic patterns of sensitivity differences between algorithms. After accounting for different rates of test reliability, SFR can result in significant time savings compared with SS. Clinicians should be cognizant of false positive rates and seeding point errors as common sources of error for SFR. Results between algorithms are not directly interchangeable, especially if there is a visual field deficit <19 dB.

18 June 2018 in Brain Injury
Verified
Journal Article
Closed access
RMRevathy Mani
Revathy Mani
LALisa Asper
Lisa Asper
SKSieu K Khuu
Sieu K Khuu
Purpose: To conduct a review of literature and quantify the effect that traumatic brain injury (TBI) has on oculomotor functions (OM). Methods: A systematic review and meta-analysis was conducted from papers that objectively measured saccades and smooth-pursuit eye movements in mild and severe TBI. Results: The overall impact of TBI on OM functions was moderate and significant with an effect size of 0.42 from 181 OM case-control comparisons. The heterogeneity, determined using the random effect model, was found to be significant (Q (180) = 367, p < 0.0001, I2 = 51) owing to the variety of OM functions (reflexive saccades, antisaccades, memory-guided saccades, self-paced saccades and pursuits) measured and varying post-injury periods.The overall effect on OM functions were similar in mild and severe TBI despite differences in combined effect size of various OM functions. OM functions involving complex cognitive skills such as antisaccades (in mild and severe TBI) and memory-guided saccades (in mild TBI) were the most adversely affected, suggesting that OM deficits may be associated with cognitive deficits in TBI. Conclusion: TBI often results in long-standing OM deficits. Experimental measures of OM assessment reflect neural integrity and may provide a sensitive and objective biomarker to detect OM deficits following TBI.

1 June 2015 in Investigative Ophthalmology & Visual Science
Verified
Journal Article
Closed access
PDF file
SKSieu K. Khuu
Sieu K. Khuu
MKMichael Kalloniatis
Michael Kalloniatis
Purpose.: To establish Ricco's critical area (Ac) using the 30-2 Humphrey visual field analyzer (HVFA) and thereby identify Goldmann test sizes that are within or outside complete spatial summation at all visual field testing locations. We also determined the suitability of using age normative data for different test sizes. Finally, by modifying current output measures (dB values), we provide a new method that allows comparison of contrast sensitivity when testing with different Goldmann test sizes within complete spatial summation. Methods.: We used the HVFA in full threshold mode and measured thresholds for all five Goldmann test sizes in 12 observers. Normative data of Heijl et al. were used for age transformation and comparison. Results.: All the data converted to a 50-year-old equivalent lie within 1 SD of expected variance for all test locations of the 30-2 paradigm. We established Ac values at all locations of the 30-2 paradigm and showed a systematic increase in Ac as a function of increased visual field eccentricity, consistent with previous studies. Age does not appear to affect Ac or the slope of partial summation for a wide range of visual field eccentricities tested using the HVFA. By equating spatial summation, we propose a new metric, dB*, that returns a uniform sensitivity value for different test sizes that are operating within complete spatial summation (i.e., follow Ricco's law). Conclusions.: We established that converting to age-equivalent thresholds and application of dB* principle advantageously allows comparison of data sets across age and test size at different locations of the visual field. By identifying the Ac across the visual field, it is now possible to systematically determine threshold changes across the 30-2 locations in ocular disease and further characterize the importance of testing within complete spatial summation in standard automated perimetry.

2 January 2015 in Journal of Vision
Verified
Journal Article
Open access
PDF file
SKSieu K. Khuu
Sieu K. Khuu
MKMichael Kalloniatis
Michael Kalloniatis
In the present study, we measured the extent of spatial summation in the detection of image contrast within the central 40° visual field. Contrast detection thresholds (in 28 observers) were measured for a spot of light of 10 different sizes [area: 0.03–1.92(°)2] at different retinal meridians (0°, 45°, 90°, 135°, 180°, 225°, 270°, and 315°) and eccentricities (0°, 5°, 10°, 15°, and 20°). Contrast detection thresholds were significantly affected by the size of the stimulus with sensitivity improving with stimulus size consistent with Ricco's law. Summation curves were similar across different spatial meridians, but the extent of spatial summation increased with retinal eccentricity consistent with previous reports. The size of the stimulus was also shown to affect contrast detection thresholds in the periphery. In particular, contrast detection thresholds decreased more rapidly with increasing eccentricity for a smaller target than a larger one. This difference in performance is accounted for by the accompanying change in Ac with eccentricity. In Experiment 2, we show that spatial uncertainty affected contrast detection, particularly at eccentric locations greater than 5°, such that cueing the location of the stimulus improved contrast thresholds. Spatial uncertainty improved overall performance but did not affect the estimates of the critical areas of summation. The results of the present study indicate that, due to spatial summation, detection performance is highly dependent on the size of the stimulus, its eccentric location, and spatial uncertainty. Future perimetric methodologies must consider these factors to improve detection sensitivity.

1 March 2005 in Vision Research
Verified
Journal Article
Closed access
DBDavid Badcock
David Badcock
CCColin W.G. Clifford
Colin W.G. Clifford
SKSieu K. Khuu
Sieu K. Khuu