William Daniels

William Daniels

Auto-generated profile, based on publicly available information

William Daniels

Department of Environmental Health and Engineering, Johns Hopkins University, Baltimore, USA

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 July 2023 in Environmental Science & Technology
Verified
Journal Article
Open access
WDWilliam S. Daniels
William S. Daniels
JWJiayang Lyra Wang
Jiayang Lyra Wang
ARArvind Ravikumar
Arvind Ravikumar
MHMatthew Harrison
Matthew Harrison
SRSelina A. Roman-White
Selina A. Roman-White
DHDorit M. Hammerling
Dorit M. Hammerling
Government policies and corporate strategies aimed at reducing methane emissions from the oil and gas sector increasingly rely on measurement-informed, site-level emission inventories, as conventional bottom-up inventories poorly capture temporal variability and the heavy-tailed nature of methane emissions. This work is based on an 11-month methane measurement campaign at oil and gas production sites. We find that operator-level top-down methane measurements are lower during the end-of-project phase than during the baseline phase. However, gaps persist between end-of-project top-down measurements and bottom-up site-level inventories, which we reconcile with high-frequency data from continuous monitoring systems (CMS). Specifically, we use CMS to (i) validate specific snapshot measurements and determine how they relate to the temporal emission profile of a given site and (ii) create a measurement-informed, site-level inventory that can be validated with top-down measurements to update conventional bottom-up inventories. This work presents a real-world demonstration of how to reconcile CMS rate estimates and top-down snapshot measurements jointly with bottom-up inventories at the site level. More broadly, it demonstrates the importance of multiscale measurements when creating measurement-informed, site-level emission inventories, which is a critical aspect of recent regulatory requirements in the Inflation Reduction Act, voluntary methane initiatives such as the Oil and Gas Methane Partnership 2.0, and corporate strategies.

20 March 2024 in Elementa: Science of the Anthropocene
Verified
Journal Article
Open access
PDF file
WDWilliam S. Daniels
William S. Daniels
MJMeng Jia
Meng Jia
DHDorit M. Hammerling
Dorit M. Hammerling
We propose a modular framework for methane emission detection, localization, and quantification on oil and gas production sites that uses concentration and wind data from point-in-space continuous monitoring systems. The framework leverages a gradient-based spike detection algorithm to estimate emission start and end times (event detection) and pattern matches simulated and observed concentrations to estimate emission source location (localization) and rate (quantification). The framework was evaluated on a month of non-blinded, single-source controlled releases ranging from 0.50 to 8.25 h in duration and 0.18 to 6.39 kg/h in size. All controlled releases are detected and 82% are localized correctly; 5.5% of estimated events are false positives. For emissions ≤1 kg/h, the framework underestimates the emission rate by −3.9% on average, with 90% of rate estimates falling within a percent difference of [−74.9%, 195.2%] from the true rate. For emissions >1 kg/h, the framework overestimates the emission rate by 4.3% on average, with 90% of rate estimates falling within a percent difference of [−49.3%, 78.8%] from the true rate. Potential uses for the proposed framework include near real time alerting for rapid emission mitigation and emission quantification for use in measurement-informed inventories on production sites.

28 October 2024 in Environmental Science & Technology Letters
Verified
Journal Article
Open access
WDWilliam S. Daniels
William S. Daniels
MJMeng Jia
Meng Jia
DHDorit M. Hammerling
Dorit M. Hammerling
We propose a method for estimating methane emission durations on oil and gas sites, referred to as the Probabilistic Duration Model (PDM), that uses concentration data from continuous monitoring systems (CMS). The PDM probabilistically addresses a key limitation of CMS: nondetect times, or the times when wind blows emitted methane away from the CMS sensors (resulting in no detections). Output from the PDM can be used to bound the duration of emissions detected by survey-based technologies, such as plane or satellites, that have limited ability to characterize durations due to the typically low temporal frequency (e.g., quarterly) at which they observe a given source. Linear regression indicates that the PDM has a bias of -4.9% (R2 = 0.80) when evaluated on blinded controlled releases at the Methane Emissions Technology Evaluation Center (METEC), with 86.8% of estimates within a factor of 2× error from the true duration. We apply the PDM to a typical production site in the Appalachian Basin and use it to bound the duration of survey-based measurements. We find that failing to account for CMS nondetect times results in underestimated emission durations of up to a factor of 65× (6400%) on this site.

18 March 2025 in ACS ES&T Air
Verified
Journal Article
Open access
WDWilliam S. Daniels
William S. Daniels
SKSpencer G. Kidd
Spencer G. Kidd
SYShuting Yang
Shuting Yang
SSShannon Stokes
Shannon Stokes
ARArvind Ravikumar
Arvind Ravikumar
DHDorit M. Hammerling
Dorit M. Hammerling
We compare continuous monitoring systems (CMS) from three different vendors on six operating oil and gas sites in the Appalachian Basin using several months of data. We highlight similarities and differences between the three CMS solutions when deployed in the field and compare their output to concurrent top-down aerial measurements and to site-level bottom-up inventories. Furthermore, we compare vendor-provided emission rate estimates to estimates from an open-source quantification algorithm applied to the raw CMS concentration data. This experimental setup allows us to separate the effect of the sensor platform (i.e., sensor type and arrangement) from the quantification algorithm. We find that 1) localization and quantification estimates rarely agree between the three CMS solutions on short time scales (i.e., 30 min), but temporally aggregated emission rate distributions are similar between solutions, 2) differences in emission rate distributions are generally driven by the quantification algorithm, rather than the sensor platform, 3) agreement between CMS and aerial rate estimates varies by CMS solution but is close to parity when CMS estimates are averaged across solutions, and 4) similar sites with similar bottom-up inventories do not necessarily have similar emission characteristics. These results have important implications for developing measurement-informed inventories and for incorporating CMS-inferred emission characteristics into emission mitigation efforts.

14 May 2023 in ChemRxiv
Verified
Preprint
Open access
PDF file
WDWilliam Daniels
William Daniels
JWJiayang (Lyra) Wang
Jiayang (Lyra) Wang
ARArvind Ravikumar
Arvind Ravikumar
MHMatthew Ross Harrison
Matthew Ross Harrison
SRSelina Roman-White
Selina Roman-White
DHDorit Hammerling
Dorit Hammerling
Government policies and corporate strategies aimed at reducing methane emissions from the oil and gas sector increasingly rely on measurement-informed emissions inventories, as conventional bottom-up inventories poorly capture temporal variability and the heavy-tailed nature of methane emissions. This work is based on an 11-month methane measurement campaign at oil and gas production sites. We find that operator-level top-down methane measurements are lower during the end-of-project phase than during the baseline phase. However, gaps persist between end-of-project top-down measurements and bottom-up inventories, which we reconcile with high-frequency data from continuous monitoring systems (CMS). Specifically, we use CMS to (i) validate specific snapshot measurements and determine how they relate to the temporal emissions profile of a given site and (ii) create a measurement-informed, site-level inventory that can be validated with top-down measurements to update conventional bottom-up inventories. This work presents a real-world demonstration of how to reconcile CMS rate estimates and top-down snapshot measurements jointly with bottom-up inventories at the site-level. More broadly, it demonstrates the importance of multi-scale measurements when creating measurement-informed emissions inventories, which is a critical aspect of recent regulatory requirements in the Inflation Reduction Act, voluntary methane initiatives such as OGMP 2.0, and corporate strategies.

7 May 2025 in ACS ES&T Air
Verified
Journal Article
Closed access
OKOlga Khaliukova
Olga Khaliukova
YZYuanrui Zhu
Yuanrui Zhu
WDWilliam S. Daniels
William S. Daniels
ARArvind Ravikumar
Arvind Ravikumar
GRGregory B. Ross
Gregory B. Ross
DHDorit M. Hammerling
Dorit M. Hammerling