Zhonghui Wang

Zhonghui Wang

Auto-generated profile, based on publicly available information

Zhonghui Wang

State Grid Liaoning Electric Power Supply Co. Ltd,Shenyang,China

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 July 2023 in Medicine
Verified
Journal Article
Open access
JPJing Peng
Jing Peng
LZLi Zhao
Li Zhao
YWYasong Wang
Yasong Wang
HYHanyan Yang
Hanyan Yang
HWHan Bd Wang
Han Bd Wang
ZWZhonghui Wang
Zhonghui Wang
The objective was to explore the relationships between computed tomography (CT) lung volume parameters and pulmonary function test (PFT) indexes and develop predictive scores to predict PFT indexes in Chinese preoperative patients suspected with lung cancer. Preoperative patients suspected with lung cancer aged 18 years or more and examined by chest CT scan and PET were consecutively recruited from April to August 2020, at Yunnan Cancer Hospital. CT and PET data were selected from medical record. Pearson correlation was used to explore the relationships between CT parameters and PFT indexes. Predictive scores of PFT indexes were developed from unstandardized coefficients of linear regression models of using CT parameters as predictors. The assessments of predictive ability of scores were conducted by receiver operating characteristics curves. A total of 124 preoperative patients suspected with lung cancer participated in this study. Total lung volume significantly correlated with total lung capacity ( r = 0.708), residual volume ( r = 0.411), forced expiratory volume in one second (FEV1, r = 0.535), forced vital capacity (FVC, r = 0.687), and FEV1/FVC ( r = −0.319). Percent of low attenuation volume significantly correlated with total lung capacity ( r = 0.200), residual volume ( r = 0.215), FEV 1 percentage of predictive value (FEV 1 %, r = −0.204) and FEV 1 /FVC ( r = −0.345). Four predictive scores for FEV 1 , FEV 1 %, FEV 1 /FVC and FVC% were developed. The area under the curve of receiver operating characteristics for FEV 1 <2L, FEV 1 % <80%, FEV 1 /FVC <80% and FVC% <80% were 0.856, 0.667, 0.749 and 0.715, respectively. A prediction of poor lung function in preoperative patients suspected with lung cancer, using total lung volume and percent of low attenuation volume was possible. The predictive scores should be further evaluated for external validity.

22 September 2023
Verified
Conference Paper
Closed access
Gang LiuGang Liu
Gang Liu
MWMiao Wang
Miao Wang
Qingsong ZhaoQingsong Zhao
Qingsong Zhao
ZWZhonghui Wang
Zhonghui Wang
MZMeishan Zhang
Meishan Zhang
DLDianyang Li
Dianyang Li
With the construction of new power system and electricity market, the adjustable resources and market entities in the power system are constantly enriched, which puts forward higher requirements for system flexibility and market mechanism. Energy storage is an important means to improve the system regulation capacity, and low-cost, low-constraint electric heat storage technology is the best way to solve the problem of surplus renewable energy consumption and winter heating pollution. Therefore, this paper analyzes the operation characteristics of electric heat storage, proposes a method and mechanism to participate in the electricity spot market, and establishes an optimized clearing model including renewable energy consumption, electric heat storage load, cross-sectional constraint and node electricity price, on this basis, optimizes the operation mode of electric heat storage, improves the renewable energy absorption capacity, and reduces the overall operating cost and energy efficiency of the system. An example verifies the effectiveness of the proposed model and algorithm.