Auro Atsushi Tanaka

Auro Atsushi Tanaka

Auto-generated profile, based on publicly available information

Auro Atsushi Tanaka

Department of Chemistry Federal University of Maranhão Dos Portugueses Av., 1966 65080-805 São Luís, MA Brazil

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 May 2021 in Electrocatalysis
Verified
Journal Article
Closed access
PDF file
URUlisses Alves Do Rêgo
Ulisses Alves Do Rêgo
RSRicardo Sgarbi
Ricardo Sgarbi
TLThiago Lopes
Thiago Lopes
CSClenilton Santos
Clenilton Santos
ATAuro A. Tanaka
Auro A. Tanaka
ETEdson A Ticianelli
Edson A Ticianelli

24 August 2022 in ChemCatChem
Verified
Journal Article
Closed access
MRMakson Rangel de Melo Rodrigues
Makson Rangel de Melo Rodrigues
RFRayse Machado Ferreira
Rayse Machado Ferreira
FPFellipe dos Santos Pereira
Fellipe dos Santos Pereira
FSFelipe Anchieta e Silva
Felipe Anchieta e Silva
ASAUGUSTO CESAR AZEVEDO SILVA
AUGUSTO CESAR AZEVEDO SILVA
TRThenner Silva Rodrigues
Thenner Silva Rodrigues

6 June 2024 in Analytical Methods
Verified
Journal Article
Closed access
PDF file
DFDianderson C. M. Ferreira
Dianderson C. M. Ferreira
NINélio I. G. Inoque
Nélio I. G. Inoque
ATAuro Atsushi Tanaka
Auro Atsushi Tanaka
LDLuiza M. F. Dantas
Luiza M. F. Dantas
Rodrigo A. A. MunozRodrigo A. A. Munoz
Rodrigo A. A. Munoz
ISIranaldo S. da Silva
Iranaldo S. da Silva
The ivermectin (IVM), as a broad-spectrum antiparasitic drug, was widely prescribed to treat COVID-19 during the pandemic, despite lacking proven efficacy in combating this disease. Therefore, it is important to establish affordable devices in laboratories with minimal infrastructure. The laser engraving technology has been revolutionary in sensor manufacturing, primarily attributed to the diversity of substrates that can be employed and the freedom it provides in creating sensor models. In this work, electrochemical sensors based on graphene were developed using the laser engraving technology for IVM sensing. Through, the studies that used the techniques of cyclic voltammetry and differential pulse voltammetry, following parameter optimization, for the laser-induced graphene electrode demonstrated a mass transport governed by adsorption of the species and exhibited a linear working range of 10–100 (μmol L−1), a limit of detection (LOD) of 1.6 × 10−6 (mol L−1), a limit of quantification (LOQ) of 4.8 × 10−6 (mol L−1), and a sensitivity of 0.139 (μA μmol L−1). The developed method was successfully applied to direct analysis of pharmaceutical tablets, tap water (recovery of 94%) and synthetic urine samples (recovery between 97% and 113%). These results demonstrate the feasibility of the method for routine analyses involving environmental samples.

8 March 2021 in Brazilian Journal of Analytical Chemistry
Verified
Journal Article
Closed access
ESElizaura Silva
Elizaura Silva
ILIlanna Lopes
Ilanna Lopes
EBEvellin Bruzaca
Evellin Bruzaca
PCPaulina Andréa Carvalho
Paulina Andréa Carvalho
ATAuro Atsushi Tanaka
Auro Atsushi Tanaka
Triclosan (TCS) is an antiseptic agent widely used mainly in personal care products and an important contaminant, which degrades in the environment causing toxicity on health, including negative effects on DNA. In this context, an electrochemical investigation of TCS in aqueous solution was studied by voltammetric techniques. The TCS underwent irreversible oxidation in a pH-dependent process, leading to the formation of two reversibly oxidized and pH-dependent oxidation products. An oxidation mechanism for TCS and its oxidation products in neutral aqueous medium was proposed. Besides that, the TCS spontaneously degraded into supporting eletrolytes with 3.4 ≤ pH ≤ 12.04 over the incubation time and the degraded TCS in solution was detected by electrochemical and spectrophotometric techniques. A higher degradation of TCS was observed in alkaline medium. In addition, the interaction in situ of this anti-microbial with DNA was investigated using dsDNA incubated solutions and dsDNA electrochemical bisosensor, by voltammetry. TCS and degraded TCS interacted with dsDNA causing the condensation of the double helix structure, release of guanine (by TCS and dedraded TCS) and adenine (by degraded TCS) bases from dsDNA and a possible intercalation of degraded TCS in the polynucleotide chain. No dsDNA oxidative damage was detected.

11 November 2022 in ChemCatChem
Verified
Journal Article
Closed access
MRMakson Rangel de Melo Rodrigues
Makson Rangel de Melo Rodrigues
RFRayse Machado Ferreira
Rayse Machado Ferreira
FPFellipe dos Santos Pereira
Fellipe dos Santos Pereira
FSFelipe Anchieta e Silva
Felipe Anchieta e Silva
ASAUGUSTO CESAR AZEVEDO SILVA
AUGUSTO CESAR AZEVEDO SILVA
TRThenner Silva Rodrigues
Thenner Silva Rodrigues