Michael H. Li

Michael H. Li

Auto-generated profile, based on publicly available information

Michael H. Li

KITEToronto Rehabilitation Institute, University Health NetworkTorontoONM5G 2A2Canada

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 April 2019 in Journal of Medical Internet Research
Verified
Journal Article
Open access
APAdam Palanica
Adam Palanica
PFPeter Flaschner
Peter Flaschner
ATAnirudh Thommandram
Anirudh Thommandram
MLMichael Li
Michael Li
YFYan Fossat
Yan Fossat
Journal of Medical Internet Research - International Scientific Journal for Medical Research, Information and Communication on the Internet #Preprint #PeerReviewMe: Warning: This is a unreviewed preprint. Readers are warned that the document has not been peer-reviewed by expert/patient reviewers or an academic editor, may contain misleading claims, and is likely to undergo changes before final publication, if accepted, or may have been rejected/withdrawn. Readers with interest and expertise are encouraged to sign up as peer-reviewer, if the paper is within an open peer-review period. Please cite this preprint only for review purposes or for grant applications and CVs (if you are the author). Background: Many potential benefits have been theorized on the uses for chatbots within the context of healthcare, such as improved patient education and treatment compliance. However, little is known about the perspectives of practicing medical physicians on the use of chatbots in healthcare, even though these individuals are the traditional benchmark of proper patient care. Objective: This study investigates the perceptions of physicians regarding the use of healthcare chatbots, including their benefits, challenges, and risks to patients. Methods: One hundred (100) practicing physicians across the United States completed a web-based, self-report survey to examine their opinions of chatbot technology in healthcare. Descriptive statistics and frequencies were used to examine the characteristics of participants. Results: A wide variety of positive and negative perspectives were reported on the use of healthcare chatbots, including the importance to patients for managing their own health, and the benefits on physical, psychological, and behavioral health outcomes. More consistent agreement occurred with regard to administrative benefits associated with chatbots; many physicians believed that chatbots would be most beneficial for scheduling doctor appointments (78%), locating health clinics (76%), or providing medication information (71%). Conversely, many physicians believed that chatbots cannot effectively care for all of patients’ needs (76%), cannot display human emotion (72%), and cannot provide detailed diagnosis and treatment due to not knowing all of the personal factors associated with the patient (71%). Many physicians also stated that healthcare chatbots could be a risk to patients if they self-diagnose too often (74%) and do not accurately understand the diagnoses (74%). Conclusions: Physicians believe in both costs and benefits associated with chatbots, depending on the logistics and specific roles of the technology. Chatbots may have a beneficial role to play in healthcare to support, motivate, and coach patients, as well as for streamlining organizational tasks; in essence, chatbots could become a surrogate for non-medical caregivers. However, concerns remain on the inability of chatbots to comprehend the emotional state of humans, as well as in areas where expert medical knowledge and intelligence is required.

6 November 2018 in Journal of NeuroEngineering and Rehabilitation
Verified
Journal Article
Open access
PDF file
MLMichael H. Li
Michael H. Li
Tiago A. MestreTiago A. Mestre
Tiago A. Mestre
SFSusan H. Fox
Susan H. Fox
BTBabak Taati
Babak Taati
Despite the effectiveness of levodopa for treatment of Parkinson’s disease (PD), prolonged usage leads to development of motor complications, most notably levodopa-induced dyskinesia (LID). Persons with PD and their physicians must regularly modify treatment regimens and timing for optimal relief of symptoms. While standardized clinical rating scales exist for assessing the severity of PD symptoms, they must be administered by a trained medical professional and are inherently subjective. Computer vision is an attractive, non-contact, potential solution for automated assessment of PD, made possible by recent advances in computational power and deep learning algorithms. The objective of this paper was to evaluate the feasibility of vision-based assessment of parkinsonism and LID using pose estimation. Nine participants with PD and LID completed a levodopa infusion protocol, where symptoms were assessed at regular intervals using the Unified Dyskinesia Rating Scale (UDysRS) and Unified Parkinson’s Disease Rating Scale (UPDRS). Movement trajectories of individual joints were extracted from videos of PD assessment using Convolutional Pose Machines, a pose estimation algorithm built with deep learning. Features of the movement trajectories (e.g. kinematic, frequency) were used to train random forests to detect and estimate the severity of parkinsonism and LID. Communication and drinking tasks were used to assess LID, while leg agility and toe tapping tasks were used to assess parkinsonism. Feature sets from tasks were also combined to predict total UDysRS and UPDRS Part III scores. For LID, the communication task yielded the best results (detection: AUC = 0.930, severity estimation: r = 0.661). For parkinsonism, leg agility had better results for severity estimation (r = 0.618), while toe tapping was better for detection (AUC = 0.773). UDysRS and UPDRS Part III scores were predicted with r = 0.741 and 0.530, respectively. The proposed system provides insight into the potential of computer vision and deep learning for clinical application in PD and demonstrates promising performance for the future translation of deep learning to PD clinical practices. Convenient and objective assessment of PD symptoms will facilitate more frequent touchpoints between patients and clinicians, leading to better tailoring of treatment and quality of care.

11 May 2016 in IEEE Journal of Biomedical and Health Informatics
Verified
Journal Article
Closed access
MLMichael H. Li
Michael H. Li
AYAzadeh Yadollahi
Azadeh Yadollahi
BTBabak Taati
Babak Taati
Individuals with obstructive sleep apnea (OSA) can experience partial or complete collapse of the upper airway during sleep. This condition affects between 10-17% of adult men and 3-9% of adult women, requiring arousal to resume regular breathing. Frequent arousals disrupt proper sleeping patterns and cause daytime sleepiness. Untreated OSA has been linked to serious medical issues including cardiovascular disease and diabetes. Unfortunately, diagnosis rates are low (~20%) and current sleep monitoring options are expensive, time consuming, and uncomfortable. Toward the development of a convenient, noncontact OSA monitoring system, this paper presents a simple, computer vision-based method to monitor cardiopulmonary signals (respiratory and heart rates) during sleep. System testing was performed with 17 healthy participants in five different simulated sleep positions. To monitor cardiopulmonary rates, distinctive points are automatically detected and tracked in infrared image sequences. Blind source separation is applied to extract candidate signals of interest. The optimal respiratory and heart rates are determined using periodicity measures based on spectral analysis. Estimates were validated by comparison to polysomnography recordings. The system achieved a mean percentage error of 3.4% and 5.0% for respiratory rate and heart rate, respectively. This study represents an important step in building an accessible, unobtrusive solution for sleep apnea diagnosis.

14 October 2019 in IEEE Journal of Translational Engineering in Health and Medicine
Verified
Journal Article
Open access
KZKaiyin Zhu
Kaiyin Zhu
MLMichael Li
Michael Li
SASina Akbarian
Sina Akbarian
MHMaziar Hafezi
Maziar Hafezi
AYAzadeh Yadollahi
Azadeh Yadollahi
BTBabak Taati
Babak Taati
A reliable, accessible, and non-intrusive method for tracking respiratory and heart rate is important for improving monitoring and detection of sleep apnea. In this study, an algorithm based on motion analysis of infrared video recordings was validated in 50 adults referred for clinical overnight polysomnography (PSG). The algorithm tracks the displacements of selected feature points on each sleeping participant and extracts respiratory rate using principal component analysis and heart rate using independent component analysis. For respiratory rate estimation (mean ± standard deviation), 89.89 % ± 10.95 % of the overnight estimation was accurate within 1 breath per minute compared to the PSG-derived respiratory rate from the respiratory inductive plethysmography signal, with an average root mean square error (RMSE) of 2.10 ± 1.64 breaths per minute. For heart rate estimation, 77.97 % ± 18.91 % of the overnight estimation was within 5 beats per minute of the heart rate derived from the pulse oximetry signal from PSG, with mean RMSE of 7.47 ± 4.79 beats per minute. No significant difference in estimation of RMSE of either signal was found according to differences in body position, sleep stage, or amount of the body covered by blankets. This vision-based method may prove suitable for overnight, non-contact monitoring of respiratory rate. However, at present, heart rate monitoring is less reliable and will require further work to improve accuracy.

1 August 2014
Verified
Conference Paper
Closed access
MLMichael H. Li
Michael H. Li
AYAzadeh Yadollahi
Azadeh Yadollahi
BTBabak Taati
Babak Taati
A non-contact vision-based system is presented for continuous respiratory rate monitoring. The system identifies feature points in a video feed and tracks them over time. Two methods are presented for comparison - a method which uses principal component analysis (PCA) and a simple averaging approach. These methods condense the feature point trajectories into a compact set of representative signals. The signal which most closely resembles an expected respiratory trace is selected based on spectral analysis. System performance is assessed by comparing the estimated respiratory rate to the rate determined via inductance plethysmogram. The system was evaluated on 5 participants in 4 simulated sleep scenarios. Accuracies of within 1 breath/minute were achieved for more than 97% of the recorded time in all scenarios. The proposed system is accurate, cost-effective, and simple, making it a suitable candidate for at-home installation.

1 August 2018 in Parkinsonism & Related Disorders
Verified
Journal Article
Closed access
MLMichael H. Li
Michael H. Li
Tiago A. MestreTiago A. Mestre
Tiago A. Mestre
SFSusan H. Fox
Susan H. Fox
BTBabak Taati
Babak Taati