Qihan Hu

Qihan Hu

Auto-generated profile, based on publicly available information

Qihan Hu

Department of Biomedical Engineering, School of Information Science and Technology, Fudan University, Shanghai, P. R. China

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

10 November 2023 in IEEE Journal of Biomedical and Health Informatics
Verified
Journal Article
Closed access
JLJian Liu
Jian Liu
SHShuaicong Hu
Shuaicong Hu
YWYa'Nan Wang
Ya'Nan Wang
QHQihan Hu
Qihan Hu
DWDaomiao Wang
Daomiao Wang
CYCuiwei Yang
Cuiwei Yang
Objective: The proliferation of wearable devices has escalated the standards for photoplethysmography (PPG) signal quality. This study introduces a lightweight model to address the imperative need for precise, real-time evaluation of PPG signal quality, followed by its deployment and validation utilizing our integrated upper computer and hardware system. Methods: Multiscale Markov Transition Fields (MMTF) are employed to enrich the morphological information of the signals, serving as the input for our proposed hybrid model (HM). HM undergoes initial pre-training utilizing the MIMIC-III and UCI databases, followed by fine-tuning the Queensland dataset. Knowledge distillation (KD) then transfers the large-parameter model's knowledge to the lightweight hybrid model (LHM). LHM is subsequently deployed on the upper computer for real-time signal quality assessment. Results: HM achieves impressive accuracies of 99.1% and 96.0% for binary and ternary classification, surpassing current state-of-the-art methods. LHM, with only 0.2 M parameters (0.44% of HM), maintains high accuracy despite a 2.6% drop. It achieves an inference speed of 0.023 s per image, meeting real-time display requirements. Furthermore, LHM attains a 97.7% accuracy on a self-created database. HM outperforms current methods in PPG signal quality accuracy, demonstrating the effectiveness of our approach. Additionally, LHM substantially reduces parameter count while maintaining high accuracy, enhancing efficiency and practicality for real-time applications. Conclusion: The proposed methodology demonstrates the capability to achieve high-precision and real-time assessment of PPG signal quality, and its practical validation has been successfully conducted during deployment. Significance: This study contributes a convenient and accurate solution for the real-time evaluation of PPG signals, offering extensive application potential.

31 October 2024 in Applied Soft Computing
Verified
Journal Article
Closed access
JLJian Liu
Jian Liu
SHShuaicong Hu
Shuaicong Hu
YWYanan Wang
Yanan Wang
WXWei Xiang
Wei Xiang
QHQihan Hu
Qihan Hu
CYCuiwei Yang
Cuiwei Yang

30 March 2024 in Expert Systems with Applications
Verified
Journal Article
Closed access
DWDaomiao Wang
Daomiao Wang
QHQihan Hu
Qihan Hu
CCChunge Cao
Chunge Cao
XFXujian Feng
Xujian Feng
HWHong Wu
Hong Wu
CYCuiwei Yang
Cuiwei Yang

18 October 2024 in IEEE Internet of Things Journal
Verified
Journal Article
Closed access
JLJian Liu
Jian Liu
HZHengtian Zhu
Hengtian Zhu
WXWei Xiang
Wei Xiang
SHShuaicong Hu
Shuaicong Hu
QHQihan Hu
Qihan Hu
CYCuiwei Yang
Cuiwei Yang
Cardiovascular disease remains a leading global health challenge, necessitating precise and continuous monitoring of blood pressure (BP) and cardiac function. Traditional noninvasive measurement techniques often present operational complexities and discomfort, while photoplethysmography (PPG) technology lacks the ability to capture comprehensive hemodynamic parameters. Herein, we introduce an innovative Internet of Medical Things (IoMT) framework for personalized hemodynamic assessment, driven by advanced flexible sensing technologies and multiscale modeling. Specifically, we propose a pulse wave detection system utilizing microfiber Bragg grating ( $\mu $ FBG) sensors for comprehensive spatiotemporal monitoring. The system leverages a multiscale perception network (MSP-Net) to achieve precise BP estimation, with mean errors (MEs) and standard deviations (SDs) of $- 0.05~\pm ~2.15$ mmHg for systolic BP (SBP) and $- 0.19~\pm ~3.48$ mmHg for diastolic BP (DBP). The system’s performance surpasses traditional PPG-based methods across multiple hemodynamic parameters. Leveraging pretraining and fine-tuning strategies, this study realizes personalized estimation models, furnishing technical support for precision medicine. Furthermore, we utilize a cloud-edge collaborative framework to achieve hemodynamic assessment across multiple IoMT devices via local area network and the RV1126 platform, providing real-time feedback, thereby establishing a closed-loop control system. Our study presents an innovative approach for the comprehensive assessment of cardiovascular function and the realization of personalized medicine, potentially serving as a promising solution for Healthcare 5.0 applications.

20 February 2025 in Expert Systems with Applications
Verified
Journal Article
Closed access
JLJian Liu
Jian Liu
SHShuaicong Hu
Shuaicong Hu
YWYanan Wang
Yanan Wang
QHQihan Hu
Qihan Hu
DWDaomiao Wang
Daomiao Wang
CYCuiwei Yang
Cuiwei Yang