Geonjun Choi

Geonjun Choi

Auto-generated profile, based on publicly available information

Geonjun Choi

Department of Mechanical Engineering Ulsan National Institute of Science and Technology (UNIST) Ulsan 44919 Republic of Korea

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 September 2024 in Science Advances
Verified
Journal Article
Open access
SPSeongjin Park
Seongjin Park
DKDong Kwan Kang
Dong Kwan Kang
DLDonghyuk Lee
Donghyuk Lee
GCGeonjun Choi
Geonjun Choi
JKJaeil Kim
Jaeil Kim
HJHoon Eui Jeong
Hoon Eui Jeong
The precise control of crack propagation at bonded interfaces is crucial for smart adhesives with advanced performance. However, previous studies have primarily concentrated on either microscale or macroscale crack propagation. Here, we present a hybrid adhesive that integrates microarchitectures and macroscopic nonlinear cut architectures for unparalleled adhesion control. The integration of these architectural elements enables conformal attachment and simultaneous crack trapping across multiple scales for high capacity, enhancing adhesion by more than 70×, while facilitating crack propagation at the macroscale in specific directions for programmable release and reusability. As adhesion strength and directionality can be independently controlled at any location, skin adhesive patches are created that are breathable, nondamaging, and exceptionally strong and secure yet remove easily. These capabilities are demonstrated with a skin-mounted adhesive patch with integrated electronics that accurately detects human motion and wirelessly transmits signals, enabling real-time control of avatars in virtual reality applications.

12 September 2025 in Advanced Science
Verified
Journal Article
Open access
SLSang‐Woo Lee
Sang‐Woo Lee
HSHyeonseok Song
Hyeonseok Song
JKJinseo Kim
Jinseo Kim
GCGeonjun Choi
Geonjun Choi
JKJaeil Kim
Jaeil Kim
HJHoon Eui Jeong
Hoon Eui Jeong
Skin‐interfacing electrodes are essential for wearable bioelectronics, yet conventional gel‐ and dry‐type electrodes often suffer from dehydration, poor skin conformity, irritation, and delamination during motion, limiting their long‐term performance. Here, a self‐attachable liquid metal channel (S‐LMC) patch is presented that integrates open‐bottom Galinstan microchannels and micropillar arrays, both featuring re‐entrant geometries for enhances skin adhesion and leakage suppression. A via‐hole interconnect enables direct vertical signal transmission, eliminating the need for bulky wiring and facilitating compact integration. The patch achieves strong, reusable skin adhesion (>60 kPa), low contact impedance (7.35 kΩ·cm 2 at 10 Hz), and minimal skin irritation. Compared to commercial Ag/AgCl gel electrodes, the S‐LMC patch exhibits >5× lower impedance, >2× higher ECG signal fidelity (20.23 dB vs. 9.03 dB under motion), and >2.4× higher long‐term adhesion after 7 days. Its re‐entrant microarchitecture also improves Galinstan confinement, achieving >2× higher critical pressure for leakage. These features enable motion‐resilient biosignal monitoring and scalable system integration, establishing the S‐LMC patch as a promising platform for next‐generation skin‐conformal bioelectronic interfaces.

25 January 2025 in Nano Select
Verified
Journal Article
Open access
SLSang‐Woo Lee
Sang‐Woo Lee
GCGeonjun Choi
Geonjun Choi
JKJaeil Kim
Jaeil Kim
SPSeongjin Park
Seongjin Park
SKSomi Kim
Somi Kim
HJHoon Eui Jeong
Hoon Eui Jeong
Hydrogels have emerged as promising materials for flexible and wearable devices due to their mechanical softness and biocompatibility. However, conventional hydrogels often fail to combine multiple essential functions, such as reusable dry adhesion, strong wet adhesion, and electrical conductivity. Here, we present a multifunctional hydrogel patch that integrates polyethylene glycol dimethacrylate (PEGDMA) with poly(3,4‐ethylenedioxythiophene):polystyrene sulfonate (PEDOT:PSS). The hydrogel features bioinspired mushroom‐shaped micropillars that adapt to target surfaces. This design achieves exceptional adhesion strength on both dry (129.2 kPa) and wet surfaces (116.3 kPa), maintaining its performance through 300 cycles. By incorporating PEDOT:PSS into the PEGDMA network, we significantly enhance the electrical conductivity, enabling effective Joule heating. The micropillar architecture ensures uniform contact with various surfaces, leading to efficient heat transfer. This hydrogel patch represents a significant step forward in flexible and wearable technologies by combining mechanical flexibility, electrical and thermal conductivity, and robust, reversible adhesion in a single material.

10 April 2025 in IEEE Journal of Solid-State Circuits
Verified
Journal Article
Closed access
YPYou Jang Pyeon
You Jang Pyeon
JCJeonghoon Cho
Jeonghoon Cho
GCGeonjun Choi
Geonjun Choi
JYJunyeong Yeom
Junyeong Yeom
HKHyunjoong Kim
Hyunjoong Kim
JKJae Joon Kim
Jae Joon Kim
This article introduces an adhesive interposer-based reconfigurable multi-sensor patch interface with on-chip quantized time-domain feature extraction, tailored for heterogeneous physiological and environmental monitoring. A proposed patch concept includes integrated micro-scale structures for comfortable pressure-based reconfiguration, allowing easy attachment and detachment of various sensor elements. For embedding edge-computing capability into a miniaturized patch device with a conventional legacy microcontroller, its multi-sensor interface integrated circuit (IC) is proposed to include on-chip analog feature extraction and classification engines of quantized time-domain convolutional neural network (QTD-CNN) and one-shot computing binary neural network (BNN). The design employs 1-bit past-data quantization, analog normalization, and flexible time window schemes to minimize leakage problems in conventional analog engines and supports reconfigurable operations for healthcare and environmental applications. This interface IC includes five types of readout frontends for chemo-resistive sensors, electrochemical sensors, biopotentials, bioimpedance, and photoplethysmogram, where every path is designed to provide both wide dynamic range (DR) and compensation capability of gain and offset. A system-level prototype of the adhesive interposer-based reconfigurable patch interface has been developed, demonstrating its effectiveness in gas event and arrhythmia detection with hit rates of 91% and 92%, respectively.