1 August 2016 in Journal of Atmospheric and Solar-Terrestrial Physics
19 May 2015 in Advances in Meteorology
Positive cloud-ground lightning is considerably more complex and less studied compared to the negative lightning. This paper aims to measure and characterize the significant parameters of positive return strokes electric field, namely, the zero-to-peak rise time, 10–90% rise time, slow front duration, fast transition rise time (10–90%), zero-crossing time, and opposite polarity overshoot relative to peak. To the best of the authors’ knowledge, this is the first time such detailed characteristics of positive lightning in Malaysia are thoroughly analyzed. A total of 41 positive lightning flashes containing 48 return strokes were analyzed. The average multiplicity is 1.2 strokes per flash. The majority of positive lightning was initiated from the primary positive charge rather than as a byproduct of in-cloud discharges. The cumulative probability distribution of rise time parameters, opposite polarity overshoot relative to peak, and slow front amplitude relative to peak are presented. A comparison between studies in four countries representing tropic, subtropic, and temperate regions was also carried out. Measured parameters in Florida, Sweden, and Japan are generally lower than those in Malaysia. Positive lightning occurrences in tropical regions should be further studied and analyzed to improve our current understanding on positive return strokes.
2 May 2021 in IET Renewable Power Generation
Biomass is one of the most versatile sustainable energy sources. This versatility allows utilization of different biomass feedstock using a verity of conversion techniques. Often, a biomass‐to‐bioenergy conversion method is selected depending on the application, end‐use product, and the type of feedstock. In many applications such as residential energy supply, it is possible to select amongst various technologies. Although, there exist several challenges such as cost‐effectiveness and sustainability that constrains bioenergy development. To this end, this research elaborates on the impacts of different conversion methods on techno‐economic performance of bioenergy systems for residential energy supply. In this context, Organic Rankine Cycle based on direct combustion, and Dual Fluidized‐Bed technology based on gasification were selected for that purpose. A techno‐economic comparative analysis illustrates that the primary product of the system and fuel cost are the two most important factors in feasibility assessment. The negative impact of feedstock price was more severe on the Organic Rankine Cycle. For wood chips prices below 55$/t, Organic Rankine Cycle could be the better option due to lower capital and maintenance costs. In contrast, Dual Fluidized‐Bed could better tolerate the variation of feedstock price; offering 8% lower cost of energy at 65$/t wood chips.
1 January 2016 in Applied Mechanics and Materials
Lightning has been the major cause of power interruptions in Malaysia. Malaysia is located near the equator having approximately 200 thunder days per year. It is known to be among the highest lightning activity country worldwide. TNB as the main power supply utility in Malaysia has made an effort to reduce the power interruptions via installation of Lightning Detection Network (LDN) in 1994. This paper presents the history leading to modern LDN that capture lightning radiation fields at multiple remote sensors. The network has undergone a series of improvement between 2004 and 2009 in response to evolving detection technologies and requirements. Recent analyses on actual performance of the current LDN are also summarized. The paper includes short and long term requirements for improving the lightning measurements needed to address some open scientific questions and fill the needs of emerging applications.
15 September 2013 in Jurnal Teknologi (Sciences & Engineering)
Zinc oxide (ZnO) gapless surge arresters are used for lightning and overvoltage protection in electrical power system. The leakage current monitoring is one of the well known method for the ZnO surge arrester ageing level determination. However, the ZnO leakage current is known to be dependent on the ambient temperature. This paper aims to study the effects of temperature variation due to ambient conditions on the leakage current of ZnO surge arrester. The effect of a significant increment of leakage current with an increase in temperature may result in a wrong assesment of the ageing level of the arrester. The leakage current of three 120kV rated polymeric housed ZnO surge arresters were measured in a custom made thermally insulated enclosures at varying temperatures. Up to 20% increase in the leakage current was observed with a 20°C increment above the ambient temperature. For a typical variation of ambient temperature in Malaysia in the range of between 30°C and 40°C, the corresponding changes in the leakage current can be up to 11%. The temperature does significantly affect the leakage current measurements used for monitoring of zinc oxide surge arresters. This significant change in the leakage current due to ambient temperature variation can affect the decision in assessing the condition of surge arresters during routine monitoring.