Noortje Catharina Hagemeijer

Noortje Catharina Hagemeijer

Auto-generated profile, based on publicly available information

Noortje Catharina Hagemeijer

Foot & Ankle Research and Innovation Laboratory, Massachusetts General Hospital, Harvard Medical School, USA; Department of Orthopaedic Surgery, Amsterdam Movement Sciences, Amsterdam UMC, Location AMC, University of Amsterdam, Meibergdreef 9, 1105 AZ, Amsterdam, the Netherlands; Academic Center for Evidence based Sports Medicine (ACES), Amsterdam UMC, Meibergdreef 9, 1105 AZ Amsterdam, the Netherlands

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 May 2020 in Foot & Ankle International
Verified
Journal Article
Closed access
PDF file
RBRohan Bhimani
Rohan Bhimani
SESoheil Ashkani Esfahani
Soheil Ashkani Esfahani
BLBart Lubberts
Bart Lubberts
DGDaniel Guss
Daniel Guss
NHNoortje C. Hagemeijer
Noortje C. Hagemeijer
CDChristopher W. DiGiovanni
Christopher W. DiGiovanni
Weight-bearing computed tomography (WBCT) allows evaluation of the distal syndesmosis under physiologic load. We hypothesized that WBCT volumetric measurement of the distal syndesmosis would be increased on the injured as compared to the contralateral uninjured side and that these 3-dimensional (3D) calculations would be a more sensitive determinant than 2-dimensional (2D) methodology among patients with syndesmotic instability. Twelve patients with unilateral syndesmotic instability requiring operative fixation who underwent preoperative bilateral foot and ankle WBCT were included in the study group. The control group consisted of 24 patients without ankle injury who underwent similar imaging. On WBCT scan, 2D measurements of the syndesmosis joint were first measured 1 cm above the joint line in the axial plane via syndesmotic area and distances between the anterior, middle, and posterior quadrants. Thereafter, comparative 3D volumetric measurements of the syndesmotic joint were also calculated: (1) from the tibial plafond extending until 3 cm proximally, (2) 5 cm proximally, and (3) 10 cm proximally. In patients with unilateral syndesmotic instability, all 3 weight-bearing volumetric measurements were significantly larger on the injured side as compared to the contralateral, uninjured side (P < .001). In the control group, there was no difference between syndesmotic volumes at any level. Of these 3 anatomic reference points, the 3D measurement spanning from the tibial plafond to a level 5 cm proximally had the highest relative volumetric ratio between the injured and uninjured side, suggesting it is the most sensitive in distinguishing between stable and unstable syndesmotic injury (P < .001). Notably, this 3D volumetric measurement was also more sensitive than 2D measurements (P = .001). 3D volumetric measurement of the syndesmosis joint appears to be the most effective way to diagnose syndesmotic instability, compared with more traditional 2D syndesmosis measurement. Level III, retrospective comparative study.

23 August 2019 in Foot & Ankle International
Verified
Journal Article
Closed access
PDF file
NHNoortje Catharina Hagemeijer
Noortje Catharina Hagemeijer
SCSong Ho Chang
Song Ho Chang
MAMohamed Elghazy Abdelaziz
Mohamed Elghazy Abdelaziz
JCJack Christopher Casey
Jack Christopher Casey
GWGregory Richard Waryasz
Gregory Richard Waryasz
CDChristopher William DiGiovanni
Christopher William DiGiovanni
Early recognition of syndesmotic instability is critical for optimizing clinical outcome. Injuries causing a more subtle instability, however, can be difficult to diagnose. The purpose of this study was to evaluate both distal tibiofibular articulations using weightbearing computed tomography (CT) in patients with known syndesmotic instability, thereafter comparing findings between the injured and uninjured sides. We also aimed to define the range of normal measurement variation among patients without syndesmotic injury. Patients with unilateral syndesmotic instability requiring operative fixation (n = 12) underwent preoperative bilateral ankle weightbearing CT. A separate cohort of patients without ankle injury who also underwent bilateral ankle weightbearing CT were included as comparative controls (n = 24). For each weightbearing CT, a series of 7 axial plane tibiofibular joint measurements, including 1 angular measurement, were utilized to evaluate parameters of the syndesmotic anatomy at a level 1 cm above the tibial plafond. Values were recorded by 2 independent observers to assess for interobserver reliability. Among those with unilateral syndesmotic instability, values differed between the injured and uninjured sides in 4 of the 7 measurements performed including the syndesmotic area: direct anterior, middle, and posterior differences, and sagittal translation (P < .001, < .001, < .001, and < .001, respectively). In the control population without ankle injury, no differences were identified between any of the bilateral measurements (P value range, .172-.961). This study highlights the ability of weightbearing CT to effectively differentiate syndesmotic diastasis among patients with surgically confirmed syndesmotic instability from those without syndesmotic instability. It underscores the substantial utility and importance of using the contralateral, uninjured side as a valid internal control whenever the need for confirming potential syndesmotic instability arises. Prospective studies are necessary to fully understand the accuracy of weightbearing CT in diagnosing occult syndesmotic instability among patients for whom the diagnosis remains in question. Level III, comparative diagnostic study.

19 February 2022 in Injury
Verified
Journal Article
Open access
JBJan De Bruijn
Jan De Bruijn
NHNoortje C. Hagemeijer
Noortje C. Hagemeijer
QRQuinten G.H. Rikken
Quinten G.H. Rikken
JHJad S. Husseini
Jad S. Husseini
JSJirawat Saengsin
Jirawat Saengsin
CDChristopher W. DiGiovanni
Christopher W. DiGiovanni
To compare diagnostic parameters for Lisfranc instability on WB and NWB radiographs and to assess the inter-observer reliability of a standardized diagnostic protocol. Patients who had undergone surgical treatment for subtle, purely ligamentous Lisfranc injury with both WB and NWB post-injury, pre-surgery films (n = 26) were included in this multicentre, retrospective comparative study. Also included was a control group (n = 26) of patients with isolated fifth metatarsal avulsion fractures who similarly had both WB and NWB films. Multiple midfoot distance and alignment measurements were used to evaluate the Lisfranc joint on both WB and NWB views. To evaluate interobserver reliability, measurements were made by two independent observers across a cohort subset. When comparing the NWB views between groups, only C1M2 (medial cuneiform- second metatarsal) distance was found to be significantly larger (∆ = 1.35 mm, p <0.001) for Lisfranc injuries. Most notably, C2M2 (Intermediate cuneiform - second metatarsal) step off-caused by lateral translation of the second metatarsal base-was not significantly different (∆ = 0.39 mm, p = 0.101) between Lisfranc patients and controls. On WB views, Lisfranc patients had significantly larger changes to C1M2 distance and C2M2 step-off as compared to controls (∆ = 2.97 mm, p <0.001 and ∆ = 1.98 mm, p <0.001 respectively). M1M2 (first to second intermetatarsal) distance was not significantly different between patients and controls in WB films. Within the cohort of ligamentous Lisfranc patients, C1M2 distance and C2M2 step-off were significantly larger in WB when compared to NWB films (∆ = 1.77 mm, p <0.001 and ∆ = 1.58 mm, p 0. 90 were found when interpreting WB radiographs and ICC's ranging between 0.61 and 0.80 were found when interpreting NWB radiographs. Using WB imaging for diagnosing subtle Lisfranc instability reveals larger diastasis in the tarsometatarsal joint and has a higher interobserver reliability compared to NWB imaging. Clinical concern for subtle or occult Lisfranc instability in any patient should therefore trigger WB radiographic assessment since such injuries may be missed on NWB views.

25 May 2020 in Knee Surgery, Sports Traumatology, Arthroscopy
Verified
Journal Article
Open access
PDF file
NHNoortje C. Hagemeijer
Noortje C. Hagemeijer
MEMohamed Abdelaziz Elghazy
Mohamed Abdelaziz Elghazy
GWGregory Waryasz
Gregory Waryasz
DGDaniel Guss
Daniel Guss
CDChristopher W. DiGiovanni
Christopher W. DiGiovanni
GKGino M. M. J. Kerkhoffs
Gino M. M. J. Kerkhoffs
Purpose: Ankle arthroscopy is widely used for diagnosis of syndesmotic instability, especially in subtle cases. To date, no published article has systematically reviewed the literature in aggregate to understand which instability values should be used intraoperatively. The primary aim was to systematically review the amount of tibiofibular displacement that correlates with syndesmotic instability after a high ankle sprain. A secondary aim is to assess the quality of such research.Methods: Systematic searches of EMBASE (Ovid) and MEDLINE via PubMed, CINAHL, Web of Science, and Google Scholar were used. Inclusion criteria: studies that arthroscopically evaluated the fibular displacement at various stages of syndesmotic ligament injury. Two reviewers independently extracted data and assessed methodological quality using the Anatomical Quality Assessment (AQUA) Tool and methodological index for non‐randomized studies (MINORS).Results: Eight cadaveric studies and three clinical studies were included for review. All studies reported displacement in the coronal plane, four studies reported in the sagittal plane, and one reported findings in the rotational plane. Four cadaveric studies had a similar experimental set up and the weighted mean associated with instability in the coronal plane could be calculated and was 2.9 mm at the anterior portion of the distal tibiofibular joint and 3.4 mm at the posterior portion. Syndesmotic instability in the sagittal plane is less extensively studied, however available data from a cadaveric study suggests thresholds of 2.2 mm of posterior fibular translation when performing an anterior to posterior hook test and 2.6 mm of anterior fibular translation when performing a posterior to anterior hook test.Conclusions: The results have concluded that the commonly used 2.0 mm threshold value of distal tibiofibular diastasis may lead to overtreatment of syndesmotic instability, and that using threshold values of 2.9 mm measured at the anterior portion of the incisura and 3.4 mm at the posterior portion may represent better cut off values. Given the ready availability of 3 mm probes among standard arthroscopic instrumentation, at the very least surgeons should use 3 mm in lieu of 2 mm probes intraoperatively.Level of evidence: IV.

1 November 2020 in Injury
Verified
Journal Article
Closed access
NHN.C. Hagemeijer
N.C. Hagemeijer
JSJ. Saengsin
J. Saengsin
SCSong Ho Chang
Song Ho Chang
GWG.R. Waryasz
G.R. Waryasz
GKGino M.M.J. Kerkhoffs
Gino M.M.J. Kerkhoffs
CDC.W. DiGiovanni
C.W. DiGiovanni

17 March 2017 in The American Journal of Sports Medicine
Verified
Journal Article
Closed access
NHNoortje C. Hagemeijer
Noortje C. Hagemeijer
FCFemke M.A.P. Claessen
Femke M.A.P. Claessen
RHRoel de Haan
Roel de Haan
RRRoeland Riedijk
Roeland Riedijk
DEDenise E. Eygendaal
Denise E. Eygendaal
MBMichel P. van Den Bekerom
Michel P. van Den Bekerom
Background: It is unclear which tendon harvest for ulnar or lateral collateral ligament reconstruction has the lowest graft site morbidity rate. Purposes: To obtain graft site morbidity rates after tendon harvest for ulnar and lateral collateral ligament reconstruction procedures. Study Design: Systematic review/Meta-analysis. Methods: Studies were eligible if (1) patients had undergone elbow ligament reconstruction procedures; (2) original data for at least 5 patients were available; (3) the article was written in English, German, or Dutch; (4) a full-text article was available; and (5) information about graft site morbidity was available. The review excluded studies about complicated elbow ligament reconstruction procedures due to initial fractures, revision procedures, or circumferential graft techniques; animal studies; (systematic) reviews; and expert opinions. Because the majority of studies were case reports, no selection form or overall scoring system to evaluate methodological quality was used. Results: The review included 619 patients with an ulnar or lateral collateral ligament reconstruction procedure. The autograft types used included palmaris longus tendon (58%), gracilis tendon (24%), semitendinosus tendon (8%), triceps tendon (7%), toe extensor tendon (<2%), plantaris tendon (<2%), extensor carpi radialis longus tendon (<1%), and Achilles tendon (<1%). Conclusion: Graft site morbidity occurred in 1% of the patients after an ulnar or lateral collateral ligament reconstruction procedure. This study did not have enough samples of all the autograft types to conclude that autograft type and graft site morbidity are unrelated.