Brenda D. Fernandez Martinez

Brenda D. Fernandez Martinez

Auto-generated profile, based on publicly available information

Brenda D. Fernandez Martinez

Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA, USA

Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 October 2026 in Science Robotics
Verified
Journal Article
Closed access
BYBinbin Ying
Binbin Ying
AJAhmad Mujtaba Jebran
Ahmad Mujtaba Jebran
SBSahab Babaee
Sahab Babaee
KJKaren Jiang
Karen Jiang
BMBrenda D. Fernandez Martinez
Brenda D. Fernandez Martinez
GTGiovanni Traverso
Giovanni Traverso
Diagnosing and treating small intestinal disorders such as bleeding, inflammatory bowel disease, and tumors present challenges because of limited access to this anatomical compartment. We present BIOSENTER, a bioinspired soft enteroscopic robot for deep procedures in the small intestine that addresses locomotion, steering, and intervention constraints of existing soft robotic systems. BIOSENTER features a hollow cylinder architecture comprising a linearly deformable soft pneumatic actuator as the body, two radially expandable soft pneumatic actuators wrapped with kirigami sleeves as the head and tail, a central hollow channel for accessory endoscopic tools, and a control box for navigation. Inspired by snake locomotion, the robotic body incorporates a fiber-reinforced actuator with four embedded inflatable chambers, enabling steering and axial expansion. The dynamic kirigami sleeves generate an anchoring force of ∼1.5 newtons on intestinal mucosa while requiring substantially less radial expansion than the corresponding nonkirigami configuration. A reinforced central channel supports tool passage for diagnostic and therapeutic interventions. The control box enables locomotion and steering at autonomous speeds of ∼100 millimeters per minute in vitro and ∼43 millimeters per minute in tissue-covered tubing. BIOSENTER successfully navigated the collapsed, tortuous small intestine for 2 meters in 11 minutes, with gentle forward pushing forces of 2.2 to 6.4 newtons in pig studies. In vivo pig studies demonstrated technical feasibility of tissue biopsy, localized fluid delivery as a model for future drug administration, and real-time visualization of the deep intestine, without macroscopic overdistention or visible tissue damage under the tested conditions.